ISH1224A-H Equivalent & Substitute Parts Reference

Part Overview

The ISH1224A-H is an isolated DC-DC converter module manufactured by XP Power. It provides a single 24V output at 83mA from a 10.8V–13.2V input, rated at 2W output power, and offers 3kV isolation. This module features surface-mount packaging and is suited for ITE (Commercial) applications. As the ISH1224A-H is classified as obsolete, identification of direct substitutes with equivalent electrical and mechanical specifications is necessary to maintain form, fit, and functional compatibility in existing designs.

Substiute Parts

ISH1224A-H
XP PowerIn Stock: 769ISH1224A-H Datasheet
ISH1224A-H
Current Part
IES0212S24-H
XP PowerIn Stock: 1049IES0212S24-H Datasheet
IES0212S24-H
MFR Recommended
PESE2-S12-S24-M
CUI Inc.In Stock: 728PESE2-S12-S24-M Datasheet
PESE2-S12-S24-M
MFR Recommended

Key Parameters

Manufacturer Part NumberManufacturerSeriesProduct StatusTypeNumber of OutputsVoltage - Input (Min)Voltage - Input (Max)Voltage - Output 1Current - Output (Max)Power (Watts)Voltage - IsolationApplicationsOperating TemperatureEfficiencyMounting TypePackage / CaseSize / DimensionRoHS StatusMoisture Sensitivity Level (MSL)
ISH1224A-HXP PowerISH (2W)ObsoleteIsolated Module110.8V13.2V24V83mA2 W3 kVITE (Commercial)-40°C ~ 105°C84%Surface Mount8-SMD Module, 5 Leads0.50" x 0.33" x 0.29" (12.7mm x 8.3mm x 7.3mm)ROHS3 Compliant1 (Unlimited)

Substitute Part Grouping Explanation

Substitute parts are selected based strictly on matching the following key parameters: isolation voltage, input voltage range, output voltage, maximum output current, output power rating, number of outputs, type, mounting type, package/case dimensions, application, efficiency, and compliance status. All listed substitute DC-DC isolated modules meet these criteria.

Parameter Comparison

Manufacturer Part Number Manufacturer Series Product Status Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension RoHS Status Moisture Sensitivity Level (MSL)
ISH1224A-H XP Power ISH (2W) Obsolete Isolated Module 1 10.8V 13.2V 24V 83mA 2 W 3 kV ITE (Commercial) -40°C ~ 105°C 84% Surface Mount 8-SMD Module, 5 Leads 0.50" x 0.33" x 0.29" (12.7mm x 8.3mm x 7.3mm) ROHS3 Compliant 1 (Unlimited)
IES0212S24-H XP Power IES02 (2W) Active Isolated Module 1 10.8V 13.2V 24V 83mA 1.992 W 3 kV ITE (Commercial) -40°C ~ 105°C (With Derating) 85% Surface Mount 8-SMD Module, 5 Leads 0.52" x 0.33" x 0.29" (13.2mm x 8.5mm x 7.3mm)
PESE2-S12-S24-M CUI Inc. PESE2-M (2W) Active Isolated Module 1 10.8V 13.2V 24V 83mA 1.992 W 3 kV ITE (Commercial) -40°C ~ 105°C (With Derating) 85% Surface Mount 8-SMD Module, 5 Leads 0.52" x 0.33" x 0.29" (13.2mm x 8.5mm x 7.3mm) ROHS3 Compliant 1 (Unlimited)

Engineering Selection Recommendations

The ISH1224A-H is designated obsolete. Substitute models IES0212S24-H (XP Power) and PESE2-S12-S24-M (CUI Inc.) are active, available, and match the provided electrical, mechanical, and compliance parameters, including isolation rating, power, voltage range, package type, and RoHS compliance.

Frequently Asked Questions (FAQ)

Q1: What are the key criteria for substituting the ISH1224A-H DC-DC converter?
A1: Substitutes must match the electrical specifications (input/output voltage, output current, power rating, isolation), as well as mechanical characteristics (package size, pinout, mounting type) and compliance status.

Q2: Are the substitute parts compatible with the existing footprint of ISH1224A-H?
A2: The listed substitute parts use the same 8-SMD Module, 5 Leads package and similar dimensions, supporting mechanical compatibility with existing layouts.

Q3: Is there any difference in environmental or compliance status among the listed substitutes?
A3: The substitutes maintain equivalent RoHS compliance and moisture sensitivity levels as the original part, ensuring compliance alignment.

Q4: Do the substitute parts support the same operating temperature range?
A4: All listed substitutes support the -40°C to 105°C range as specified, with derating where indicated.

Q5: Can the substitute models be used in ITE (Commercial) applications?
A5: All substitutes are specified for ITE (Commercial) applications in line with the ISH1224A-H designation.