ISF0515A Equivalent & Substitute Parts Reference

Part Overview

The ISF0515A by XP Power is an isolated DC-DC converter module designed for ITE (commercial) applications. It provides a single 15V output at up to 67mA with an input voltage range of 4.5V to 5.5V and a maximum power rating of 1 W. The device features surface-mount packaging in a compact 8-SMD module form factor. The ISF0515A has been designated as obsolete, necessitating the identification of equivalent or substitute models to ensure supply continuity and maintain design compatibility in legacy or ongoing projects.

Substiute Parts

ISF0515A
XP PowerIn Stock: 1101ISF0515A Datasheet
ISF0515A
Current Part
IES0105S15
XP PowerIn Stock: 893IES0105S15 Datasheet
IES0105S15
MFR Recommended
IES0105S15
XP PowerIn Stock: 893IES0105S15 Datasheet
IES0105S15
MFR Recommended

Key Parameters

ParameterISF0515A
ManufacturerXP Power
Product StatusObsolete
SeriesISF (1W)
TypeIsolated Module
Number of Outputs1
Voltage - Input (Min)4.5V
Voltage - Input (Max)5.5V
Voltage - Output 115V
Current - Output (Max)67mA
Power (Watts)1 W
Voltage - Isolation1 kV
ApplicationsITE (Commercial)
Operating Temperature-40°C ~ 85°C
Efficiency78%
Mounting TypeSurface Mount
Package / Case8-SMD Module
Size / Dimension0.50" L x 0.30" W x 0.24" H (12.7mm x 7.5mm x 6.0mm)
RoHS StatusROHS3 Compliant
Inventory1006 Pcs

Substitute Part Grouping Explanation

Substitute parts for the ISF0515A are determined strictly by matching key electrical and mechanical parameters. The following criteria are used:

  • Manufacturer and product category
  • Output voltage (15V) and maximum output current (67mA)
  • Input voltage range (4.5V to 5.5V)
  • Power rating (1 W)
  • Isolation voltage (≥1 kV)
  • Surface mount package with comparable form factor
  • Compliance status (ROHS3)
  • Application type (ITE Commercial)
  • Matching or overlapping operating temperature range
    Only parts providing identical or superior values in these parameters are considered direct substitutes.

Parameter Comparison

Parameter ISF0515A IES0105S15
ManufacturerXP PowerXP Power
Product StatusObsoleteActive
SeriesISF (1W)IES01 (1W)
TypeIsolated ModuleIsolated Module
Number of Outputs11
Voltage - Input (Min)4.5V4.5V
Voltage - Input (Max)5.5V5.5V
Voltage - Output 115V15V
Current - Output (Max)67mA67mA
Power (Watts)1 W1 W
Voltage - Isolation1 kV1.5 kV
ApplicationsITE (Commercial)ITE (Commercial)
Operating Temperature-40°C ~ 85°C-40°C ~ 105°C (With Derating)
Efficiency78%83%
Mounting TypeSurface MountSurface Mount
Package / Case8-SMD Module8-SMD Module, 5 Leads
Size / Dimension0.50" L x 0.30" W x 0.24" H (12.7mm x 7.5mm x 6.0mm)0.52" L x 0.33" W x 0.29" H (13.2mm x 8.5mm x 7.3mm)
RoHS StatusROHS3 CompliantROHS3 Compliant
Inventory1006 Pcs807 Pcs

Engineering Selection Recommendations

The ISF0515A is obsolete. The IES0105S15 is an active, ROHS3-compliant part with a matching input voltage range, output voltage, output current, power rating, and application suitability. It provides a higher isolation voltage, higher efficiency, an extended operating temperature range, and comparable mounting and packaging attributes.

Frequently Asked Questions (FAQ)

Q1: What are the most important criteria for substituting the ISF0515A?
A1: Key criteria include matching input voltage range (4.5V–5.5V), output voltage (15V), output current (67mA), power rating (1 W), isolation voltage (minimum 1 kV), surface mount form factor, RoHS compliance, and application suitability for ITE (commercial).

Q2: Is the IES0105S15 mechanically compatible with the ISF0515A?
A2: Both devices use a surface-mount module format with similar physical dimensions. Verification of PCB pad compatibility is determined by the provided size and package/case data.

Q3: Does the IES0105S15 meet or exceed the electrical parameters of the ISF0515A?
A3: The IES0105S15 matches all key electrical parameters and exceeds the original isolation rating and efficiency.

Q4: Are there compliance or certification differences between these parts?
A4: Both parts are ROHS3 compliant. The IES0105S15 includes approval agency listings and meets standard number 62368-1.

Q5: Should operating temperature range be considered when substituting?
A5: Yes, the substitute provides a broader operating temperature range, fully encompassing the original device's specified range.

Request Quote (Ships tomorrow)