Equivalent & Substitute Parts Reference: ISE1205A-H

Part Overview

ISE1205A-H is an isolated module DC-DC converter manufactured by XP Power, designed for commercial ITE applications. This model provides 1 output of 5V at 200mA, supports an input voltage range from 10.8V to 13.2V, and delivers 1W output power with 3 kV isolation. The product is classified as obsolete, making it necessary to select alternative models that match critical electrical and mechanical characteristics to ensure direct replacement suitability.

Substiute Parts

ISE1205A-H
XP PowerIn Stock: 1028ISE1205A-H Datasheet
ISE1205A-H
Current Part
IES0112S05
XP PowerIn Stock: 982IES0112S05 Datasheet
IES0112S05
MFR Recommended
IES0112S05-H
XP PowerIn Stock: 1037IES0112S05-H Datasheet
IES0112S05-H
MFR Recommended

Key Parameters

Manufacturer Part Number Series Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension Product Status Approval Agency Standard Number ECCN HTSUS
ISE1205A-H ISE (1W) Isolated Module 1 10.8V 13.2V 5V 200mA 1W 3 kV ITE (Commercial) -40°C ~ 105°C (With Derating) 80% Surface Mount 8-SMD Module, 5 Leads 0.50" x 0.33" x 0.28" Obsolete - 61000 EAR99 8504.40.9580

Substitute Part Grouping Explanation

Substitute DC-DC converter modules are identified strictly by comparison of the following allowed parameters: input voltage range, output voltage and current, power rating, isolation voltage, number of outputs, package type, mounting method, operating temperature range, and dimensions. Only parts that meet or exceed these criteria, without exceeding critical physical site constraints, are grouped as substitutes.

Parameter Comparison

Manufacturer Part Number Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension Product Status Approval Agency Standard Number ECCN HTSUS
ISE1205A-H Isolated Module 1 10.8V 13.2V 5V 200mA 1W 3 kV ITE (Commercial) -40°C ~ 105°C (With Derating) 80% Surface Mount 8-SMD Module, 5 Leads 0.50" x 0.33" x 0.28" Obsolete - 61000 EAR99 8504.40.9580
IES0112S05 Isolated Module 1 10.8V 13.2V 5V 200mA 1W 1.5 kV ITE (Commercial) -40°C ~ 105°C (With Derating) 82% Surface Mount 8-SMD Module, 5 Leads 0.52" x 0.33" x 0.29" Active CE, UKCA, UL 62368-1 EAR99 8504.40.9580
IES0112S05-H Isolated Module 1 10.8V 13.2V 5V 200mA 1W 3 kV ITE (Commercial) -40°C ~ 105°C (With Derating) 82% Surface Mount 8-SMD Module, 5 Leads 0.52" x 0.33" x 0.29" Active CE, UKCA, UL 62368-1 EAR99 8504.40.9580

Engineering Selection Recommendations

ISE1205A-H is classified as obsolete. Substitute models with identical electrical ratings and compatible mechanical formats should be selected. When certification or compliance is required, choose substitutes IES0112S05 and IES0112S05-H, which are active in production and offer CE, UKCA, and UL approvals as well as compliance to standard 62368-1. The IES0112S05-H maintains 3 kV isolation, matching ISE1205A-H, while IES0112S05 offers 1.5 kV isolation. Both substitutes provide improved efficiency. Verify product status and compliance credentials based on the application's certification requirements.

Frequently Asked Questions (FAQ)

Q1: Which electrical parameters must match when substituting ISE1205A-H?
A1: Input voltage range (10.8V to 13.2V), output voltage (5V), output current (200mA), output power (1W), and isolation voltage are mandatory matching parameters.

Q2: How does isolation voltage affect substitute selection?
A2: For applications requiring 3 kV isolation, select substitutes such as IES0112S05-H. If 1.5 kV isolation meets requirements, IES0112S05 is suitable.

Q3: What should be checked regarding mounting and package?
A3: Ensure the substitute features the 8-SMD Module, 5 Leads package type and surface mount format, matching the physical footprint and connectivity.

Q4: Are substitutes compliant with the same application standards?
A4: Substitute parts IES0112S05 and IES0112S05-H provide CE, UKCA, UL agency approvals and conform to standard 62368-1.

Q5: How do product status and inventory affect selection?
A5: Substitute parts labeled as "Active" are preferred due to continued production and available inventory, supporting ongoing procurement and maintenance requirements.