Part Overview
The ISE0505A-H is an isolated DC-DC converter module from XP Power. It provides a single 5V output at 200mA with a 4.5V to 5.5V input voltage range and a power output of 1W. The part is now classified as obsolete. Due to its obsolete status, identifying alternative models with matching electrical, mechanical, and regulatory parameters is essential for maintaining design integrity and ongoing support in applications requiring this specific isolated DC-DC converter functionality.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | ISE0505A-H |
| Series | ISE (1W) |
| Type | Isolated Module |
| Number of Outputs | 1 |
| Voltage - Input (Min) | 4.5V |
| Voltage - Input (Max) | 5.5V |
| Voltage - Output 1 | 5V |
| Current - Output (Max) | 200mA |
| Power (Watts) | 1 W |
| Voltage - Isolation | 3 kV |
| Applications | ITE (Commercial) |
| Operating Temperature | -40°C ~ 105°C (With Derating) |
| Efficiency | 80% |
| Mounting Type | Surface Mount |
| Package / Case | 8-SMD Module, 5 Leads |
| Size / Dimension | 0.50" L x 0.33" W x 0.28" H (12.7mm x 8.3mm x 7.0mm) |
Substitute Part Grouping Explanation
Substitute part selection is based strictly on alignment of electrical and mechanical parameters relevant to isolated DC-DC converter modules. The following key parameters must match for a valid substitute: input voltage range, output voltage, maximum output current, output power, voltage isolation rating, number of outputs, operating temperature range, mounting type, and package dimensions. Regulatory or compliance status and efficiency differences are also considered where specified.
Parameter Comparison
| Parameter | ISE0505A-H | IES0105S05-H |
|---|---|---|
| Manufacturer | XP Power | XP Power |
| Type | Isolated Module | Isolated Module |
| Number of Outputs | 1 | 1 |
| Voltage - Input (Min) | 4.5V | 4.5V |
| Voltage - Input (Max) | 5.5V | 5.5V |
| Voltage - Output 1 | 5V | 5V |
| Current - Output (Max) | 200mA | 200mA |
| Power (Watts) | 1 W | 1 W |
| Voltage - Isolation | 3 kV | 3 kV |
| Applications | ITE (Commercial) | ITE (Commercial) |
| Operating Temperature | -40°C ~ 105°C (With Derating) | -40°C ~ 105°C (With Derating) |
| Efficiency | 80% | 82% |
| Mounting Type | Surface Mount | Surface Mount |
| Package / Case | 8-SMD Module, 5 Leads | 8-SMD Module, 5 Leads |
| Size / Dimension | 0.50" L x 0.33" W x 0.28" H (12.7mm x 8.3mm x 7.0mm) | 0.52" L x 0.33" W x 0.29" H (13.2mm x 8.5mm x 7.3mm) |
| Product Status | Obsolete | Active |
| Packaging | - | Tube |
| Approval Agency | - | CE, TUV, UL |
| Standard Number | 61000 | 62368-1 |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8504.40.9580 | 8504.40.9580 |
Engineering Selection Recommendations
Selection should prioritize the product status, compliance, and certifications. ISE0505A-H is obsolete, whereas IES0105S05-H is active. IES0105S05-H holds additional approval certifications (CE, TUV, UL) and RoHS3 compliance. ISE0505A-H does not specify such approvals in the provided parameters. Efficiency is marginally higher in IES0105S05-H. All other essential electrical and mechanical parameters are directly aligned.
Frequently Asked Questions (FAQ)
Q1: What criteria are used to determine a valid substitute for ISE0505A-H?
A1: Substitution is determined solely by matching input voltage range, output voltage and current, power rating, voltage isolation, number of outputs, mounting type, package, and operating temperature range.
Q2: Are there any differences in package or mounting between ISE0505A-H and IES0105S05-H?
A2: Both parts use the 8-SMD Module, 5 Leads package and are intended for surface mount applications.
Q3: Is there any change in functional performance between ISE0505A-H and IES0105S05-H?
A3: Both parts share identical functional parameters per the provided data. IES0105S05-H specifies a slightly higher efficiency and includes additional compliance certifications.
Q4: Are there any differences in regulatory status or compliance?
A4: IES0105S05-H is listed as RoHS3 Compliant and holds CE, TUV, UL approvals; ISE0505A-H does not specify these certifications.
Q5: Which part should be used in new designs?
A5: Selection is based on product status and compliance. IES0105S05-H is active and compliant according to the provided parameters.
Q6: Are there differences in environmental specifications?
A6: Both parts have the same operating temperature range of -40°C to 105°C (with derating) per the provided information.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts