Part Overview

The XP Power ISE0315A-TR is an isolated module DC-DC converter designed for ITE (Commercial) applications. It delivers a single regulated 15V output at up to 67mA, from an input voltage range of 2.97V to 3.63V, with a maximum power rating of 1W. The device is surface mount, packaged in an 8-SMD module with five leads. The product is marked as obsolete, necessitating consideration of equivalent or substitute models in applications where the original is no longer available. Selection of substitute parts must ensure compliance with all specified electrical, mechanical, and regulatory parameters reflected in the main part description.

Substiute Parts

ISE0315A-TR
XP PowerIn Stock: 979ISE0315A-TR Datasheet
ISE0315A-TR
Current Part
IES0103S15
XP PowerIn Stock: 919IES0103S15 Datasheet
IES0103S15
MFR Recommended

Key Parameters

Parameter Main Part (ISE0315A-TR)
Manufacturer XP Power
Category [Not Provided]
Packaging -
Description DC DC CONVERTER 15V 1W
Detailed Description Isolated Module DC DC Converter 1 Output 15V 67mA 2.97V - 3.63V Input
Series ISE (1W)
Product Status Obsolete
Type Isolated Module
Number of Outputs 1
Voltage - Input (Min) 2.97V
Voltage - Input (Max) 3.63V
Voltage - Output 1 15V
Current - Output (Max) 67mA
Power (Watts) 1 W
Voltage - Isolation 1.5 kV
Applications ITE (Commercial)
Features SCP
Operating Temperature -40°C ~ 105°C
Efficiency 80%
Mounting Type Surface Mount
Package / Case 8-SMD Module, 5 Leads
Size / Dimension 0.50" L x 0.33" W x 0.28" H (12.7mm x 8.3mm x 7.0mm)
Standard Number 61000
RoHS Status ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)
ECCN EAR99
HTSUS 8504.40.9580

Substitute Part Grouping Explanation

Substitute selection for the XP Power ISE0315A-TR DC-DC converter is strictly limited to models matching all primary electrical, thermal, and mechanical parameters within the input criteria. These parameters include input voltage range, output voltage and current, power rating, isolation voltage, operating temperature range, mounting type, package outline and dimensions, regulatory status, and compliance certifications. Only parts that align exactly on these parameters are considered suitable substitutes.

Key parameters for substitution:

  • Input Voltage Range
  • Output Voltage and Output Current
  • Maximum Power
  • Isolation Voltage
  • Operating Temperature Range
  • Mounting and Package Type
  • RoHS and Regulatory Compliance
  • Application Category

Parameter Comparison

Parameter Main Part (ISE0315A-TR) Substitute (IES0103S15)
Manufacturer XP Power XP Power
Type Isolated Module Isolated Module
Number of Outputs 1 1
Voltage - Input (Min) 2.97V 2.97V
Voltage - Input (Max) 3.63V 3.63V
Voltage - Output 1 15V 15V
Current - Output (Max) 67mA 67mA
Power (Watts) 1 W 1.005 W
Voltage - Isolation 1.5 kV 1.5 kV
Applications ITE (Commercial) ITE (Commercial)
Operating Temperature -40°C ~ 105°C -40°C ~ 105°C (With Derating)
Efficiency 80% 84%
Mounting Type Surface Mount Surface Mount
Package / Case 8-SMD Module, 5 Leads 8-SMD Module, 5 Leads
Size / Dimension 0.50" L x 0.33" W x 0.28" H 0.52" L x 0.33" W x 0.29" H
RoHS Status ROHS3 Compliant ROHS3 Compliant
ECCN EAR99 EAR99
HTSUS 8504.40.9580 8504.40.9580

Engineering Selection Recommendations

Selection strictly considers obsolete status for the XP Power ISE0315A-TR. The listed substitute, XP Power IES0103S15, is active, RoHS3 compliant, and certified to standard 62368-1 and agency approvals CE, UKCA, and UL. Both models share identical primary specifications: input and output voltage, output current, isolation voltage, mounting type, and package outline. Compliance regarding ECCN and HTSUS codes is aligned. These factors enable the use of the substitute within compatible designs.

Frequently Asked Questions (FAQ)

Q1: What parameters must match when selecting a substitute for ISE0315A-TR?
A1: Substitutes must align in input and output voltage range, maximum output current, isolation voltage, maximum output power, mounting type, package, operating temperature range, application category, and compliance status.

Q2: Is package compatibility required for substitution?
A2: Yes. Substitution is limited to devices sharing the same 8-SMD Module, 5 Leads package and comparable physical dimensions.

Q3: Are regulatory approvals and RoHS compliance necessary for substitution?
A3: Yes. Substitute components must maintain at least equivalent regulatory and environmental compliance as detailed in the input parameters.

Q4: Does the substitute IES0103S15 maintain identical functional characteristics to ISE0315A-TR?
A4: IES0103S15 matches the main functional parameters: voltage ranges, output current, power, isolation, packaging, and mounting type.

Q5: What implications arise from product status differences?
A5: ISE0315A-TR is obsolete; active substitutes like IES0103S15 should be used to ensure ongoing availability and support.

Q6: What considerations are there regarding efficiency and certification differences?
A6: Efficiency for the substitute is higher (84% vs. 80%), and certifications are specified (CE, UKCA, UL), reflecting alignment with application and compliance requirements per provided parameters.