The Sensata-Cynergy3 IPSLU-AP015-5 is an industrial automation pressure transmitter with an absolute pressure range of 0–15PSI, providing a 4–20 mA analog current output. This part is designated as obsolete, necessitating the identification of direct alternative models for ongoing manufacturing, repair, or design requirements.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Manufacturer | Series | Pressure Type | Operating Pressure | Output Type | Output | Accuracy | Voltage - Supply | Port Size | Port Style | Features | Termination Style | Package / Case | RoHS Status | MSL | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IPSLU-AP015-5 | Sensata-Cynergy3 | IPSLU | Absolute | 15PSI (103.42kPa) | Analog Current | 4 mA ~ 20 mA | ±0.5% | 9V ~ 32V | Male - 1/4" (6.35mm) NPT | Threaded | Amplified Output, Temperature Compensated | Connector | Cylinder | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 9026.20.4000 |
Substitute Part Grouping Explanation
Substitute parts are selected by strictly matching the following key parameters: absolute pressure type, identical operating pressure (15PSI), output type (4–20 mA analog current), supply voltage overlap, port size and style (Male 1/4" NPT threaded), case design (cylinder), compliance with RoHS, and MSL 1 rating. Only parts with explicit data matching these criteria are included as valid alternatives.
Parameter Comparison
| Manufacturer Part Number | Manufacturer | Series | Pressure Type | Operating Pressure | Output Type | Output | Accuracy | Voltage - Supply | Port Size | Port Style | Features | Termination Style | Package / Case | RoHS Status | MSL | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IPSLU-AP015-5 | Sensata-Cynergy3 | IPSLU | Absolute | 15PSI (103.42kPa) | Analog Current | 4 mA ~ 20 mA | ±0.5% | 9V ~ 32V | Male - 1/4" (6.35mm) NPT | Threaded | Amplified Output, Temperature Compensated | Connector | Cylinder | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 9026.20.4000 |
| US381-000005-015PA | TE Connectivity Measurement Specialties | US300 | Absolute | 15PSI (103.42kPa) | Analog Current | 4 mA ~ 20 mA | ±0.25% | 9V ~ 30V | Male - 1/4" (6.35mm) NPT | Threaded | Amplified Output, Temperature Compensated | Cable | Cylinder | ROHS3 Compliant | 1 (Unlimited) | REACH Affected | EAR99 | 9026.20.4000 |
Engineering Selection Recommendations
The IPSLU-AP015-5 part is obsolete and is documented as ROHS3 compliant, MSL 1 (Unlimited), and REACH Unaffected. The US381-000005-015PA is active, ROHS3 compliant, MSL 1 (Unlimited), and REACH Affected. Both parts share identical compliance status for RoHS and MSL, with differentiation in REACH status. Substitute selection based on compliance should consider documented ROHS3 and MSL 1 equivalency, and review REACH status as required for application-specific directives.
Frequently Asked Questions (FAQ)
Q1: What are the primary criteria for selecting an equivalent pressure transmitter for IPSLU-AP015-5?
A1: Main criteria include pressure type (absolute), operating pressure (15PSI), output type and range (4–20 mA analog current), overlapping supply voltage, port size and style (Male 1/4" NPT threaded), package/case type (cylinder), RoHS and MSL compliance.
Q2: Are termination styles interchangeable in this category?
A2: The main part uses a connector termination, while the substitute uses a cable termination. Selection must be based on compatibility with system wiring and installation requirements.
Q3: Can both parts be used in the same physical mounting locations?
A3: Both parts utilize the cylinder package and Male 1/4" (6.35mm) NPT threaded ports, supporting mechanical interchangeability.
Q4: How does REACH status affect substitute selection?
A4: REACH Status should be verified according to the end-use application. The main part is REACH Unaffected; the substitute is REACH Affected. Select as appropriate for required regulatory compliance.
Q5: Are there any functional differences in output or accuracy?
A5: The substitute part has higher accuracy (±0.25%) compared to the main part (±0.5%), and both parts provide identical 4–20 mA output current signaling.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts