Equivalent & Substitute Parts for IML0205D15

Part Overview

The XP Power IML0205D15 is an active Isolated Module DC-DC Converter featuring dual outputs of +15V and -15V at a maximum current of 66mA each, designed for medical applications and available in a 7-SIP Module, 5 Leads through-hole package. Finding alternatives for IML0205D15 is necessary to ensure continued supply, address inventory needs, and provide engineering flexibility in designs requiring strict compliance with listed parameters.

Substiute Parts

IML0205D15
XP PowerIn Stock: 986IML0205D15 Datasheet
IML0205D15
Current Part
RKZ-0515D/HP
Recom PowerIn Stock: 12155RKZ-0515D/HP Datasheet
RKZ-0515D/HP
Direct

Key Parameters

ParameterMain Part Value
Manufacturer Part NumberIML0205D15
SeriesIML02 (2W)
Product StatusActive
TypeIsolated Module
Number of Outputs2
Voltage - Input (Min)4.5V
Voltage - Input (Max)5.5V
Voltage - Output 115V
Voltage - Output 2-15V
Current - Output (Max)66mA, 66mA
Power (Watts)2 W
Voltage - Isolation4 kV
ApplicationsMedical
FeaturesSCP
Operating Temperature-40°C ~ 85°C
Efficiency82%
Mounting TypeThrough Hole
Package / Case7-SIP Module, 5 Leads
Size / Dimension0.77" L x 0.39" W x 0.47" H (19.5mm x 9.8mm x 12.0mm)
RoHS StatusROHS3 Compliant
Moisture Sensitivity Level (MSL)1 (Unlimited)
ECCNEAR99
HTSUS8504.40.9580

Substitute Part Grouping Explanation

Substitute parts for the IML0205D15 are selected strictly based on equivalence in isolated module type, number of outputs, input and output voltage ranges, output currents, power rating, isolation voltage, medical applicability, special features (SCP), operating temperature range, mounting style, package/case, size/dimension, RoHS compliance, and moisture sensitivity level. Only components matching all listed parameters are considered suitable substitutes.

Key substitution parameters:

  • Category: Isolated Module DC-DC Converter
  • Inputs: 4.5V - 5.5V
  • Outputs: 2 outputs (15V and -15V), each 66mA
  • Power: 2W
  • Isolation: 4 kV
  • Package: 7-SIP Module, 5 Leads, Through Hole
  • Operating Temperature: -40°C ~ 85°C
  • Compliance: ROHS3, MSL 1

Parameter Comparison

Parameter IML0205D15 (XP Power) RKZ-0515D/HP (Recom Power)
Manufacturer Part NumberIML0205D15RKZ-0515D/HP
DescriptionDC DC CONVERTER +/-15V 2WDC DC CONVERTER +/-15V 2W
TypeIsolated ModuleIsolated Module
Number of Outputs22
Voltage - Input (Min)4.5V4.5V
Voltage - Input (Max)5.5V5.5V
Voltage - Output 115V15V
Voltage - Output 2-15V-15V
Current - Output (Max)66mA, 66mA66mA, 66mA
Power (Watts)2 W2 W
Voltage - Isolation4 kV4 kV
ApplicationsMedicalITE (Commercial), Medical
FeaturesSCPSCP
Operating Temperature-40°C ~ 85°C-40°C ~ 85°C
Efficiency82%84%
Mounting TypeThrough HoleThrough Hole
Package / Case7-SIP Module, 5 Leads7-SIP Module, 5 Leads
Size / Dimension0.77" L x 0.39" W x 0.47" H (19.5mm x 9.8mm x 12.0mm)0.77" L x 0.28" W x 0.40" H (19.7mm x 7.1mm x 10.2mm)
RoHS StatusROHS3 CompliantROHS3 Compliant
Moisture Sensitivity Level (MSL)1 (Unlimited)1 (Unlimited)
ECCNEAR99EAR99
HTSUS8504.40.95808504.40.9580

Engineering Selection Recommendations

Both IML0205D15 and RKZ-0515D/HP are active products, ROHS3 compliant, and feature unlimited moisture sensitivity levels (MSL 1). Both are suitable for medical applications according to provided parameters and have matching certification and compliance codes. The RKZ-0515D/HP is a suitable direct substitute where identical electrical, mechanical, and regulatory requirements are present.

Frequently Asked Questions (FAQ)

Q1: What are the primary criteria for substituting IML0205D15?
A1: The primary substitution criteria are identical isolated module category, required input voltage range, dual outputs (15V and -15V), output currents, power rating, isolation voltage, operating temperature range, mounting and package type, medical application suitability, RoHS3 compliance, and moisture sensitivity level.

Q2: Is RKZ-0515D/HP compatible in terms of form factor and assembly?
A2: RKZ-0515D/HP matches the through-hole 7-SIP Module, 5 Leads package specification, with comparable dimensions, ensuring mechanical compatibility for direct replacement.

Q3: Are there differences in application suitability?
A3: Both the IML0205D15 and RKZ-0515D/HP are listed for medical use. RKZ-0515D/HP additionally includes ITE (Commercial) applications per provided parameters.

Q4: What compliance and certifications are present in these parts?
A4: Both components are ROHS3 compliant, MSL 1 (Unlimited), and carry ECCN EAR99 and HTSUS 8504.40.9580 codes according to the supplied details.

Q5: How is performance equivalence maintained?
A5: Performance equivalence is maintained as both products share all key electrical, mechanical, and regulatory parameters specified, with only nominal difference in efficiency and dimensions within the given tolerances.

Request Quote (Ships tomorrow)