Part Overview

The ICL7665EPA is a multi-voltage supervisor IC designed for power management applications, featuring 2-channel monitoring with open drain or open collector output configuration. This component is classified as obsolete, which necessitates identification of functionally equivalent alternatives for ongoing system support and new designs. The ICL7665EPA operates across an industrial temperature range of -40°C to 85°C and is packaged in an 8-DIP through-hole format.

Substiute Parts

ICL7665EPA
Analog Devices Inc./Maxim IntegratedIn Stock: 800ICL7665EPA Datasheet
ICL7665EPA
Current Part
ICL7665AEPA+
Analog Devices Inc./Maxim IntegratedIn Stock: 700ICL7665AEPA+ Datasheet
ICL7665AEPA+
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Analog Devices Inc./Maxim Integrated
Category Power Management (PMIC)
Type Multi-Voltage Supervisor
Number of Voltages Monitored 2
Voltage Threshold Adjustable/Selectable
Output Configuration Open Drain or Open Collector
Reset Type Active High
Reset Timeout <1ms Minimum
Operating Temperature Range -40°C ~ 85°C (TA)
Mounting Type Through Hole
Package / Case 8-DIP (0.300", 7.62mm)
Supplier Device Package 8-PDIP

Substitute Part Grouping Explanation

Substitution of the ICL7665EPA is determined by strict equivalence across the following critical parameters:

  • Functional Type: Multi-voltage supervisor with 2-channel monitoring capability
  • Output Configuration: Open drain or open collector output
  • Voltage Threshold Control: Adjustable/selectable threshold settings
  • Reset Characteristics: Active high reset with <1ms minimum timeout
  • Operating Temperature Range: -40°C to 85°C
  • Package Format: 8-DIP through-hole configuration (0.300", 7.62mm)
  • Electrical Interface: Pin-compatible 8-PDIP supplier device package

The ICL7665AEPA+ meets all these criteria and qualifies as a parametric equivalent substitute. Both parts share identical functional specifications, electrical characteristics, and physical packaging, enabling direct replacement in existing circuit designs.

Parameter Comparison

Parameter ICL7665EPA ICL7665AEPA+
Manufacturer Analog Devices Inc./Maxim Integrated Analog Devices Inc./Maxim Integrated
Product Status Obsolete Active
Type Multi-Voltage Supervisor Multi-Voltage Supervisor
Number of Voltages Monitored 2 2
Voltage Threshold Adjustable/Selectable Adjustable/Selectable
Output Configuration Open Drain or Open Collector Open Drain or Open Collector
Reset Type Active High Active High
Reset Timeout <1ms Minimum <1ms Minimum
Operating Temperature Range -40°C ~ 85°C (TA) -40°C ~ 85°C (TA)
Mounting Type Through Hole Through Hole
Package / Case 8-DIP (0.300", 7.62mm) 8-DIP (0.300", 7.62mm)
Supplier Device Package 8-PDIP 8-PDIP
RoHS Status RoHS non-compliant ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8542.39.0001 8542.39.0001

Engineering Selection Recommendations

The ICL7665AEPA+ is the direct substitute for the obsolete ICL7665EPA. Both components are manufactured by Analog Devices Inc./Maxim Integrated and maintain identical electrical and mechanical specifications. The primary distinction is product status: the ICL7665EPA is obsolete, while the ICL7665AEPA+ is active and currently in production.

For new designs and ongoing system support, the ICL7665AEPA+ is the appropriate selection. This part offers improved compliance status, with ROHS3 certification compared to the non-compliant RoHS status of the original part. Both components share identical packaging (8-DIP through-hole), electrical characteristics, and functional performance, ensuring seamless integration into existing circuit designs without modification.

Frequently Asked Questions (FAQ)

Q: Can the ICL7665AEPA+ be used as a direct replacement for the ICL7665EPA?

A: Yes. Both parts are electrically and mechanically identical. The ICL7665AEPA+ is pin-compatible and functionally equivalent, requiring no circuit modifications for substitution.

Q: What is the primary reason for substituting the ICL7665EPA?

A: The ICL7665EPA is classified as obsolete. The ICL7665AEPA+ is the active production equivalent, ensuring long-term availability and supply chain continuity.

Q: Are there packaging differences between these parts?

A: Both parts use identical 8-DIP through-hole packaging (0.300", 7.62mm). The ICL7665AEPA+ is supplied in tube packaging, while the original ICL7665EPA packaging format is not specified in the technical data.

Q: What are the key parameters that define substitution eligibility?

A: Substitution is based on matching the following parameters: 2-channel multi-voltage supervisor functionality, adjustable/selectable voltage threshold, open drain or open collector output, active high reset with <1ms minimum timeout, -40°C to 85°C operating temperature range, and 8-DIP through-hole package format.

Q: Does the ICL7665AEPA+ meet current compliance requirements?

A: Yes. The ICL7665AEPA+ is ROHS3 compliant and REACH unaffected, meeting current environmental and regulatory standards. The original ICL7665EPA is RoHS non-compliant.

Q: Are there any electrical performance differences between the two parts?

A: No. Both parts maintain identical electrical specifications, including voltage monitoring capability, threshold adjustment range, reset characteristics, and operating temperature range.

Request Quote (Ships tomorrow)