Equivalent & Substitute Parts for ICH15048S24 DC-DC Converter

Part Overview

The XP Power ICH15048S24 is an isolated module DC-DC converter designed for ITE (Commercial) applications, delivering a single 24V output at 6.25A with 150W total output power. It offers 1.5 kV isolation voltage and features such as remote on/off, overvoltage protection, and short circuit protection. As an active product, alternative models may be required for sourcing flexibility, compliance needs, or design qualification within the same performance and form factor category.

Substiute Parts

ICH15048S24
XP PowerIn Stock: 1052ICH15048S24 Datasheet
ICH15048S24
Current Part
QSB15048WS24
XP PowerIn Stock: 1209QSB15048WS24 Datasheet
QSB15048WS24
MFR Recommended
MHB150-48S24
MEAN WELL USA Inc.In Stock: 1010MHB150-48S24 Datasheet
MHB150-48S24
Direct

Key Parameters

ParameterSpecification
Manufacturer Part NumberICH15048S24
SeriesICH (200W)
TypeIsolated Module
Number of Outputs1
Voltage - Input (Min)36V
Voltage - Input (Max)75V
Voltage - Output 124V
Current - Output (Max)6.25A
Power (Watts)150 W
Voltage - Isolation1.5 kV
ApplicationsITE (Commercial)
FeaturesRemote On/Off, OVP, SCP
Operating Temperature-40°C ~ 100°C
Efficiency85%
Mounting TypeThrough Hole
Package / Case9-DIP Module
Size / Dimension2.40" L x 2.28" W x 0.50" H (61.0mm x 57.9mm x 12.7mm)
Base Product NumberICH15048
RoHS StatusROHS3 Compliant
Moisture Sensitivity Level (MSL)1 (Unlimited)
ECCNEAR99
HTSUS8504.40.9580

Substitute Part Grouping Explanation

Substitution is determined strictly by matching key electrical and mechanical parameters. These include:

  • Output voltage (24V)
  • Maximum output current (6.25A)
  • Input voltage range (must cover original specification)
  • Output power (150W)
  • Isolation voltage (1.5 kV)
  • Module type and mounting (Isolated Module, Through Hole)
  • Package dimensions (2.40" x 2.28" x 0.50")
  • Compliance certifications (ROHS3, ECCN, etc.)
  • Operating temperature range (-40°C ~ 100°C)

Only substitutes meeting all the above criteria across the provided parameter set are considered direct equivalents.

Parameter Comparison

Manufacturer Part Number Manufacturer Series Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension RoHS Status MSL ECCN HTSUS
ICH15048S24 XP Power ICH (200W) Isolated Module 1 36V 75V 24V 6.25A 150 W 1.5 kV ITE (Commercial) Remote On/Off, OVP, SCP -40°C ~ 100°C 85% Through Hole 9-DIP Module 2.40" x 2.28" x 0.50" ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.9580
QSB15048WS24 XP Power QSB15048W (150W) Isolated Module 1 9V 75V 24V 6.25A 150 W 1.5 kV ITE (Commercial) Remote On/Off, OCP, OTP, SCP, UVLO -40°C ~ 100°C 89.5% Through Hole 9-DIP Module, 1/2 Brick 2.40" x 2.28" x 0.50" ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.9580
MHB150-48S24 MEAN WELL USA Inc. MHB150 (150W) Isolated Module 1 36V 75V 24V 6.25A 150 W 1.5 kV ITE (Commercial) Remote On/Off, OCP, OTP, OVP, SCP, UVLO -40°C ~ 100°C 89% Through Hole Half Brick 2.40" x 2.28" x 0.50" ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.9580

Engineering Selection Recommendations

ICH15048S24, QSB15048WS24, and MHB150-48S24 are active status products with ROHS3 compliance and ECCN EAR99 export classification. All comply with unlimited Moisture Sensitivity Level (MSL 1). These criteria allow each part to be selected as an equivalent substitute within the constraints of provided information.

Frequently Asked Questions (FAQ)

Q: What parameters must match for substitution in DC-DC converters in this category?
A: Output voltage, output current, input voltage range, isolation voltage, output power, package size, mounting type, and compliance certifications.

Q: Are packaging and case form factors equivalent for all substitute parts listed?
A: Dimensions and through-hole mounting are consistent. The listed substitutes use comparable module formats per provided specifications.

Q: Can substitute parts listed be directly implemented in the same application as ICH15048S24?
A: Based strictly on the provided electrical, mechanical, and compliance parameters, listed alternatives are equivalent for applications specified as ITE (Commercial).

Q: Does efficiency variation affect substitute qualification?
A: Substitute acceptance is determined strictly by the matching parameters provided. Efficiency values fall within acceptable ranges for this product class based on input data.

Q: Are all listed substitutes ROHS3 compliant and have the same ECCN and MSL rating?
A: All listed equivalents are ROHS3 Compliant, ECCN EAR99, and Moisture Sensitivity Level 1 (Unlimited).