HPB100R5DA Barometer Equivalent & Substitute Parts

Part Overview

The HPB100R5DA is an absolute pressure barometer sensor manufactured by Honeywell Aerospace, designed for industrial automation applications. This component features RS-485 digital output and operates across a pressure range of 7.25PSI to 17.4PSI (50kPa to 120kPa) with an accuracy specification of ±0.012PSI (±0.08kPa). The part is classified as obsolete, necessitating identification of functionally equivalent alternatives for ongoing system support and new procurement requirements.

Substiute Parts

HPB100R5DA
Honeywell AerospaceIn Stock: 810HPB100R5DA Datasheet
HPB100R5DA
Current Part
HPB200R5DA
Honeywell AerospaceIn Stock: 1005HPB200R5DA Datasheet
HPB200R5DA
Direct

Key Parameters

Parameter Value
Manufacturer Honeywell Aerospace
Pressure Type Absolute
Operating Pressure Range 7.25PSI ~ 17.4PSI (50kPa ~ 120kPa)
Output Type RS-485
Accuracy ±0.012PSI (±0.08kPa)
Voltage Supply 5.5V ~ 30V
Port Size Male - 0.13" (3.18mm) Tube
Port Style Barbed
Operating Temperature -40°C ~ 85°C
Package Type Module Cube
Termination Style Connector
RoHS Status RoHS non-compliant
Moisture Sensitivity Level 1 (Unlimited)

Substitute Part Grouping Explanation

Substitute parts for the HPB100R5DA are identified based on strict parameter matching across the following critical specifications:

Mandatory Matching Parameters:

  • Pressure Type: Absolute
  • Operating Pressure Range: 7.25PSI ~ 17.4PSI (50kPa ~ 120kPa)
  • Output Type: RS-485
  • Voltage Supply Range: 5.5V ~ 30V
  • Port Size: Male - 0.13" (3.18mm) Tube
  • Port Style: Barbed
  • Operating Temperature Range: -40°C ~ 85°C
  • Package Type: Module Cube
  • Termination Style: Connector
  • Manufacturer: Honeywell Aerospace

Allowable Variation Parameters:

  • Accuracy: May improve (lower tolerance value acceptable)
  • Product Status: Active status preferred for obsolete parts
  • Inventory Availability: Subject to current stock levels

The HPB200R5DA qualifies as a direct substitute based on complete alignment with all mandatory parameters while providing improved accuracy specification.

Parameter Comparison

Parameter HPB100R5DA (Main Part) HPB200R5DA (Substitute) Compatibility
Manufacturer Honeywell Aerospace Honeywell Aerospace Identical
Pressure Type Absolute Absolute Identical
Operating Pressure Range 7.25PSI ~ 17.4PSI (50kPa ~ 120kPa) 7.25PSI ~ 17.4PSI (50kPa ~ 120kPa) Identical
Output Type RS-485 RS-485 Identical
Accuracy ±0.012PSI (±0.08kPa) ±0.006PSI (±0.04kPa) Improved (HPB200R5DA)
Voltage Supply 5.5V ~ 30V 5.5V ~ 30V Identical
Port Size Male - 0.13" (3.18mm) Tube Male - 0.13" (3.18mm) Tube Identical
Port Style Barbed Barbed Identical
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C Identical
Package Type Module Cube Module Cube Identical
Termination Style Connector Connector Identical
Product Status Obsolete Active Substitute is active
RoHS Status RoHS non-compliant RoHS non-compliant Identical
Moisture Sensitivity Level 1 (Unlimited) 1 (Unlimited) Identical

Engineering Selection Recommendations

The HPB200R5DA barometer sensor is a direct functional equivalent to the HPB100R5DA. Selection of the HPB200R5DA is supported by the following engineering factors:

Product Status Consideration: The HPB100R5DA is classified as obsolete, while the HPB200R5DA maintains active product status with Honeywell Aerospace. Active status ensures continued manufacturer support, documentation availability, and supply chain reliability.

Compliance Alignment: Both components share identical RoHS non-compliance status and moisture sensitivity classification, ensuring no regulatory or environmental handling changes are required during substitution.

Performance Enhancement: The HPB200R5DA provides improved accuracy specification (±0.006PSI versus ±0.012PSI), representing a 50% reduction in tolerance band. This enhanced accuracy is achievable without modification to system integration, power supply requirements, or communication protocols.

Interface Compatibility: Complete mechanical and electrical interface compatibility is maintained across all connection parameters, including port geometry, termination style, and RS-485 communication protocol.

For applications where the HPB100R5DA is currently specified, direct substitution with HPB200R5DA is supported without system redesign or recalibration.

Frequently Asked Questions (FAQ)

Q: Can the HPB200R5DA replace the HPB100R5DA in existing installations?

A: Yes. The HPB200R5DA is mechanically and electrically compatible with all HPB100R5DA interface requirements. Port geometry, connector type, voltage supply range, and RS-485 communication protocol are identical. No hardware modifications are required.

Q: What is the primary difference between these two barometer sensors?

A: The HPB200R5DA provides improved accuracy specification of ±0.006PSI (±0.04kPa) compared to the HPB100R5DA specification of ±0.012PSI (±0.08kPa). All other functional parameters remain identical.

Q: Why is the HPB100R5DA classified as obsolete?

A: The HPB100R5DA is listed as obsolete by Honeywell Aerospace. The HPB200R5DA represents the active product line continuation with enhanced performance characteristics.

Q: Are there any supply chain advantages to using the HPB200R5DA?

A: Yes. The HPB200R5DA maintains active product status, which typically provides better long-term availability, documented lead times, and manufacturer technical support compared to obsolete components.

Q: Do both sensors require identical power supply specifications?

A: Yes. Both the HPB100R5DA and HPB200R5DA operate across the identical voltage supply range of 5.5V to 30V. Existing power supply configurations require no modification.

Q: Is the barbed port connection identical between both models?

A: Yes. Both sensors feature male barbed ports with 0.13" (3.18mm) tube connection. Existing tubing and pneumatic connections are directly compatible.

Q: What is the operating temperature range for both sensors?

A: Both the HPB100R5DA and HPB200R5DA operate across the identical temperature range of -40°C to 85°C. Environmental operating conditions require no adjustment.

Q: Are there any differences in moisture sensitivity handling?

A: No. Both components share identical Moisture Sensitivity Level classification of 1 (Unlimited), requiring no changes to storage, handling, or packaging procedures.