Request Quote
(Ships tomorrow)
HPB100R5DA Barometer Equivalent & Substitute Parts
Part Overview
The HPB100R5DA is an absolute pressure barometer sensor manufactured by Honeywell Aerospace, designed for industrial automation applications. This component features RS-485 digital output and operates across a pressure range of 7.25PSI to 17.4PSI (50kPa to 120kPa) with an accuracy specification of ±0.012PSI (±0.08kPa). The part is classified as obsolete, necessitating identification of functionally equivalent alternatives for ongoing system support and new procurement requirements.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer | Honeywell Aerospace |
| Pressure Type | Absolute |
| Operating Pressure Range | 7.25PSI ~ 17.4PSI (50kPa ~ 120kPa) |
| Output Type | RS-485 |
| Accuracy | ±0.012PSI (±0.08kPa) |
| Voltage Supply | 5.5V ~ 30V |
| Port Size | Male - 0.13" (3.18mm) Tube |
| Port Style | Barbed |
| Operating Temperature | -40°C ~ 85°C |
| Package Type | Module Cube |
| Termination Style | Connector |
| RoHS Status | RoHS non-compliant |
| Moisture Sensitivity Level | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitute parts for the HPB100R5DA are identified based on strict parameter matching across the following critical specifications:
Mandatory Matching Parameters:
- Pressure Type: Absolute
- Operating Pressure Range: 7.25PSI ~ 17.4PSI (50kPa ~ 120kPa)
- Output Type: RS-485
- Voltage Supply Range: 5.5V ~ 30V
- Port Size: Male - 0.13" (3.18mm) Tube
- Port Style: Barbed
- Operating Temperature Range: -40°C ~ 85°C
- Package Type: Module Cube
- Termination Style: Connector
- Manufacturer: Honeywell Aerospace
Allowable Variation Parameters:
- Accuracy: May improve (lower tolerance value acceptable)
- Product Status: Active status preferred for obsolete parts
- Inventory Availability: Subject to current stock levels
The HPB200R5DA qualifies as a direct substitute based on complete alignment with all mandatory parameters while providing improved accuracy specification.
Parameter Comparison
| Parameter | HPB100R5DA (Main Part) | HPB200R5DA (Substitute) | Compatibility |
|---|---|---|---|
| Manufacturer | Honeywell Aerospace | Honeywell Aerospace | Identical |
| Pressure Type | Absolute | Absolute | Identical |
| Operating Pressure Range | 7.25PSI ~ 17.4PSI (50kPa ~ 120kPa) | 7.25PSI ~ 17.4PSI (50kPa ~ 120kPa) | Identical |
| Output Type | RS-485 | RS-485 | Identical |
| Accuracy | ±0.012PSI (±0.08kPa) | ±0.006PSI (±0.04kPa) | Improved (HPB200R5DA) |
| Voltage Supply | 5.5V ~ 30V | 5.5V ~ 30V | Identical |
| Port Size | Male - 0.13" (3.18mm) Tube | Male - 0.13" (3.18mm) Tube | Identical |
| Port Style | Barbed | Barbed | Identical |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 85°C | Identical |
| Package Type | Module Cube | Module Cube | Identical |
| Termination Style | Connector | Connector | Identical |
| Product Status | Obsolete | Active | Substitute is active |
| RoHS Status | RoHS non-compliant | RoHS non-compliant | Identical |
| Moisture Sensitivity Level | 1 (Unlimited) | 1 (Unlimited) | Identical |
Engineering Selection Recommendations
The HPB200R5DA barometer sensor is a direct functional equivalent to the HPB100R5DA. Selection of the HPB200R5DA is supported by the following engineering factors:
Product Status Consideration: The HPB100R5DA is classified as obsolete, while the HPB200R5DA maintains active product status with Honeywell Aerospace. Active status ensures continued manufacturer support, documentation availability, and supply chain reliability.
Compliance Alignment: Both components share identical RoHS non-compliance status and moisture sensitivity classification, ensuring no regulatory or environmental handling changes are required during substitution.
Performance Enhancement: The HPB200R5DA provides improved accuracy specification (±0.006PSI versus ±0.012PSI), representing a 50% reduction in tolerance band. This enhanced accuracy is achievable without modification to system integration, power supply requirements, or communication protocols.
Interface Compatibility: Complete mechanical and electrical interface compatibility is maintained across all connection parameters, including port geometry, termination style, and RS-485 communication protocol.
For applications where the HPB100R5DA is currently specified, direct substitution with HPB200R5DA is supported without system redesign or recalibration.
Frequently Asked Questions (FAQ)
Q: Can the HPB200R5DA replace the HPB100R5DA in existing installations?
A: Yes. The HPB200R5DA is mechanically and electrically compatible with all HPB100R5DA interface requirements. Port geometry, connector type, voltage supply range, and RS-485 communication protocol are identical. No hardware modifications are required.
Q: What is the primary difference between these two barometer sensors?
A: The HPB200R5DA provides improved accuracy specification of ±0.006PSI (±0.04kPa) compared to the HPB100R5DA specification of ±0.012PSI (±0.08kPa). All other functional parameters remain identical.
Q: Why is the HPB100R5DA classified as obsolete?
A: The HPB100R5DA is listed as obsolete by Honeywell Aerospace. The HPB200R5DA represents the active product line continuation with enhanced performance characteristics.
Q: Are there any supply chain advantages to using the HPB200R5DA?
A: Yes. The HPB200R5DA maintains active product status, which typically provides better long-term availability, documented lead times, and manufacturer technical support compared to obsolete components.
Q: Do both sensors require identical power supply specifications?
A: Yes. Both the HPB100R5DA and HPB200R5DA operate across the identical voltage supply range of 5.5V to 30V. Existing power supply configurations require no modification.
Q: Is the barbed port connection identical between both models?
A: Yes. Both sensors feature male barbed ports with 0.13" (3.18mm) tube connection. Existing tubing and pneumatic connections are directly compatible.
Q: What is the operating temperature range for both sensors?
A: Both the HPB100R5DA and HPB200R5DA operate across the identical temperature range of -40°C to 85°C. Environmental operating conditions require no adjustment.
Q: Are there any differences in moisture sensitivity handling?
A: No. Both components share identical Moisture Sensitivity Level classification of 1 (Unlimited), requiring no changes to storage, handling, or packaging procedures.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts