Part Overview
The HPB100F5DA is an absolute pressure barometer sensor manufactured by Honeywell Aerospace, designed for industrial automation applications. This sensor operates within the 7.25PSI to 17.4PSI (50kPa to 120kPa) pressure range and communicates via RS-485 output protocol. The HPB100F5DA is classified as obsolete, making identification of functionally equivalent substitute parts essential for system maintenance, repair, and new design implementations where this model is no longer available through standard distribution channels.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer | Honeywell Aerospace |
| Product Category | Barometer / Sensors, Transducers |
| Pressure Type | Absolute |
| Operating Pressure Range | 7.25PSI ~ 17.4PSI (50kPa ~ 120kPa) |
| Output Type | RS-485 |
| Accuracy | ±0.012PSI (±0.08kPa) |
| Supply Voltage | 5.5V ~ 30V |
| Operating Temperature Range | -40°C ~ 85°C |
| Port Style | Filtered |
| Termination Style | Connector |
| Package / Case | Module Cube |
| Product Status | Obsolete |
Substitute Part Grouping Explanation
Substitution eligibility for the HPB100F5DA is determined by strict alignment of the following critical parameters:
Mandatory Matching Parameters:
- Pressure Type: Absolute
- Operating Pressure Range: 7.25PSI ~ 17.4PSI (50kPa ~ 120kPa)
- Output Type: RS-485
- Supply Voltage Range: 5.5V ~ 30V
- Operating Temperature Range: -40°C ~ 85°C
- Port Style: Filtered
- Termination Style: Connector
- Package / Case: Module Cube
- Manufacturer: Honeywell Aerospace
Allowable Variation Parameters:
- Accuracy: May improve (lower tolerance values acceptable)
- Product Status: Active status preferred for long-term availability
The HPB200F5DA meets all mandatory matching criteria and represents a direct functional equivalent with enhanced accuracy specifications.
Parameter Comparison
| Parameter | HPB100F5DA (Main Part) | HPB200F5DA (Substitute) |
|---|---|---|
| Manufacturer | Honeywell Aerospace | Honeywell Aerospace |
| Product Category | Barometer / Sensors, Transducers | Barometer / Sensors, Transducers |
| Pressure Type | Absolute | Absolute |
| Operating Pressure Range | 7.25PSI ~ 17.4PSI (50kPa ~ 120kPa) | 7.25PSI ~ 17.4PSI (50kPa ~ 120kPa) |
| Output Type | RS-485 | RS-485 |
| Accuracy | ±0.012PSI (±0.08kPa) | ±0.006PSI (±0.04kPa) |
| Supply Voltage | 5.5V ~ 30V | 5.5V ~ 30V |
| Operating Temperature Range | -40°C ~ 85°C | -40°C ~ 85°C |
| Port Style | Filtered | Filtered |
| Termination Style | Connector | Connector |
| Package / Case | Module Cube | Module Cube |
| Product Status | Obsolete | Active |
| RoHS Status | RoHS non-compliant | RoHS non-compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) |
| ECCN | EAR99 | EAR99 |
| HTSUS Code | 9026.20.4000 | 9026.20.4000 |
Engineering Selection Recommendations
HPB200F5DA as Primary Substitute:
The HPB200F5DA is the direct equivalent for HPB100F5DA applications. This substitute maintains identical electrical and mechanical specifications across all critical parameters: pressure range, output protocol, supply voltage, operating temperature, and physical packaging.
The HPB200F5DA provides superior accuracy at ±0.006PSI (±0.04kPa) compared to the HPB100F5DA at ±0.012PSI (±0.08kPa). This enhanced accuracy does not introduce incompatibility and represents an improvement for precision-dependent applications.
The HPB200F5DA holds Active product status, ensuring continued availability through Honeywell Aerospace distribution channels and long-term supply chain stability. This addresses the primary limitation of the obsolete HPB100F5DA.
Both parts maintain identical RoHS non-compliance status, ECCN classification (EAR99), and HTSUS coding (9026.20.4000), ensuring regulatory and compliance consistency in system integration.
Frequently Asked Questions (FAQ)
Q: Can HPB200F5DA directly replace HPB100F5DA in existing systems?
A: Yes. The HPB200F5DA maintains identical operating pressure range (7.25PSI ~ 17.4PSI), output type (RS-485), supply voltage (5.5V ~ 30V), operating temperature range (-40°C ~ 85°C), port style (Filtered), termination style (Connector), and package type (Module Cube). Connector compatibility and signal protocol are identical.
Q: What is the difference in accuracy between these parts?
A: HPB100F5DA specifies ±0.012PSI (±0.08kPa) accuracy, while HPB200F5DA specifies ±0.006PSI (±0.04kPa) accuracy. The HPB200F5DA provides twice the accuracy specification. This represents an improvement and does not create substitution barriers.
Q: Why is HPB100F5DA obsolete?
A: Product status is determined by manufacturer lifecycle decisions. The HPB100F5DA is no longer in active production. The HPB200F5DA represents the current active equivalent model from Honeywell Aerospace.
Q: Are there any compliance differences between these parts?
A: Both parts share identical RoHS status (non-compliant), ECCN classification (EAR99), HTSUS code (9026.20.4000), and Moisture Sensitivity Level (1 - Unlimited). No compliance barriers exist for substitution.
Q: What is the Module Cube package specification?
A: Module Cube is the physical package designation for both parts. This standardized form factor ensures mechanical compatibility in mounting and connector interface applications.
Q: Can HPB200F5DA be used in new designs replacing HPB100F5DA?
A: Yes. The HPB200F5DA is the recommended selection for new designs requiring this pressure sensor category. Active product status ensures long-term component availability and supply chain continuity.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts