HPA100R5DA Equivalent & Substitute Parts
Part Overview
The HPA100R5DA is an absolute pressure barometer sensor manufactured by Honeywell Aerospace, designed for industrial automation applications. This component features RS-485 digital output and operates across a wide temperature range of -40°C to 85°C. The product is currently classified as obsolete, which necessitates identification of functionally equivalent alternatives for ongoing system support and new procurement requirements.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | HPA100R5DA |
| Manufacturer | Honeywell Aerospace |
| Description | Barometer |
| Product Category | Sensors, Transducers |
| Pressure Type | Absolute |
| Operating Pressure | 17.6 PSI (121.35 kPa) |
| Output Type | RS-485 |
| Accuracy | ±0.06% |
| Voltage Supply Range | 5.5V to 30V |
| Port Size | Male - 0.13" (3.18mm) Tube |
| Port Style | Barbed |
| Termination Style | Connector |
| Operating Temperature Range | -40°C to 85°C |
| Package Type | Module Cube |
| RoHS Status | Non-compliant |
| Moisture Sensitivity Level | 1 (Unlimited) |
| ECCN Classification | EAR99 |
| HTSUS Code | 9026.20.4000 |
Substitute Part Grouping Explanation
Substitution eligibility for the HPA100R5DA is determined by strict alignment across the following critical parameters:
Mandatory Matching Parameters:
- Pressure Type: Absolute
- Operating Pressure: 17.6 PSI (121.35 kPa)
- Output Type: RS-485 digital interface
- Voltage Supply Range: 5.5V to 30V
- Port Size: Male - 0.13" (3.18mm) Tube
- Port Style: Barbed
- Termination Style: Connector
- Operating Temperature Range: -40°C to 85°C
- Package Type: Module Cube
- HTSUS Classification: 9026.20.4000
Acceptable Variation Parameters:
- Accuracy: May improve (lower tolerance value acceptable)
- Product Status: Active status preferred for ongoing availability
- Inventory Status: Current stock availability
The HPA200R5DA qualifies as a direct substitute based on complete alignment with all mandatory parameters and improved accuracy specification.
Parameter Comparison
| Parameter | HPA100R5DA (Main Part) | HPA200R5DA (Substitute) | Compatibility |
|---|---|---|---|
| Manufacturer Part Number | HPA100R5DA | HPA200R5DA | Direct Substitute |
| Manufacturer | Honeywell Aerospace | Honeywell Aerospace | Match |
| Pressure Type | Absolute | Absolute | Match |
| Operating Pressure | 17.6 PSI (121.35 kPa) | 17.6 PSI (121.35 kPa) | Match |
| Output Type | RS-485 | RS-485 | Match |
| Accuracy | ±0.06% | ±0.03% | Improved |
| Voltage Supply Range | 5.5V to 30V | 5.5V to 30V | Match |
| Port Size | Male - 0.13" (3.18mm) Tube | Male - 0.13" (3.18mm) Tube | Match |
| Port Style | Barbed | Barbed | Match |
| Termination Style | Connector | Connector | Match |
| Operating Temperature Range | -40°C to 85°C | -40°C to 85°C | Match |
| Package Type | Module Cube | Module Cube | Match |
| RoHS Status | Non-compliant | Non-compliant | Match |
| Moisture Sensitivity Level | 1 (Unlimited) | 1 (Unlimited) | Match |
| ECCN Classification | EAR99 | EAR99 | Match |
| HTSUS Code | 9026.20.4000 | 9026.20.4000 | Match |
| Product Status | Obsolete | Active | Substitute is Active |
Engineering Selection Recommendations
The HPA200R5DA is a direct functional equivalent to the HPA100R5DA for all industrial automation applications requiring absolute pressure measurement at 17.6 PSI with RS-485 digital output.
Selection Basis:
-
Product Status: The HPA100R5DA is classified as obsolete, limiting long-term availability and support. The HPA200R5DA maintains active product status, ensuring continued manufacturing support and supply chain reliability.
-
Electrical Compatibility: Both components operate identically across the 5.5V to 30V supply range and utilize the same RS-485 communication protocol, requiring no circuit modifications.
-
Mechanical Compatibility: Identical port specifications (Male - 0.13" barbed tube) and Module Cube packaging enable direct physical replacement without mechanical redesign.
-
Performance Enhancement: The HPA200R5DA provides improved accuracy at ±0.03% compared to the HPA100R5DA at ±0.06%, delivering superior measurement precision within the same operating envelope.
-
Regulatory Alignment: Both components share identical RoHS status, ECCN classification (EAR99), and HTSUS coding (9026.20.4000), maintaining consistent compliance documentation.
-
Environmental Specifications: Identical operating temperature range (-40°C to 85°C) and moisture sensitivity level (MSL 1) ensure equivalent reliability across all deployment conditions.
Frequently Asked Questions (FAQ)
Q: Can the HPA200R5DA directly replace the HPA100R5DA without circuit modifications?
A: Yes. The HPA200R5DA is electrically and mechanically compatible with the HPA100R5DA. Both components operate on identical voltage ranges (5.5V to 30V), use RS-485 output, and feature the same connector termination style. No circuit redesign is required.
Q: What is the primary difference between these two barometer sensors?
A: The HPA200R5DA provides improved measurement accuracy at ±0.03% compared to the HPA100R5DA at ±0.06%. All other electrical, mechanical, and environmental specifications are identical.
Q: Why is the HPA100R5DA listed as obsolete?
A: The HPA100R5DA has reached end-of-life status in Honeywell Aerospace's product portfolio. The HPA200R5DA represents the current active equivalent for this pressure measurement application.
Q: Are the port connections identical between these two models?
A: Yes. Both models feature Male - 0.13" (3.18mm) barbed tube ports with connector termination, enabling direct mechanical coupling without adapter requirements.
Q: Do both components have the same environmental operating range?
A: Yes. Both the HPA100R5DA and HPA200R5DA operate across -40°C to 85°C and maintain MSL 1 (Unlimited) moisture sensitivity classification.
Q: What is the operating pressure specification for these sensors?
A: Both components measure absolute pressure at 17.6 PSI (121.35 kPa) and are suitable for industrial automation applications requiring this pressure range.
Q: Are there any compliance differences between these two barometer models?
A: No. Both components share identical RoHS non-compliant status, EAR99 ECCN classification, and 9026.20.4000 HTSUS coding, maintaining consistent regulatory documentation.
Q: Can the HPA200R5DA be used in existing systems designed for the HPA100R5DA?
A: Yes. The HPA200R5DA is a direct substitute for the HPA100R5DA in all industrial automation applications. Identical specifications across pressure type, output protocol, supply voltage, port configuration, and operating temperature ensure full compatibility.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts