Request Quote
(Ships tomorrow)
HOA1883-012 Equivalent & Substitute Parts
Part Overview
The HOA1883-012 is an optical sensor manufactured by Honeywell Sensing and Productivity Solutions, classified as a through-beam phototransistor slotted module. This component features a 0.140" (3.56mm) sensing distance and unamplified output configuration. The product is currently obsolete, making identification of equivalent substitute parts essential for system maintenance, repair, and legacy equipment support. The through-hole mounting design and slotted module package are critical form factors for direct replacement applications.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | HOA1883-012 |
| Manufacturer | Honeywell Sensing and Productivity Solutions |
| Category | Optical Sensors |
| Description | SENSOR OPT SLOT PHOTOTRANS MODUL |
| Sensing Distance | 0.140" (3.56mm) |
| Sensing Method | Through-Beam |
| Output Configuration | Phototransistor |
| Current - DC Forward (If) (Max) | 50 mA |
| Voltage - Collector Emitter Breakdown (Max) | 30 V |
| Response Time | 15µs |
| Operating Temperature | -40°C ~ 85°C |
| Mounting Type | Through Hole |
| Package / Case | Slotted Module |
| Type | Unamplified |
| Product Status | Obsolete |
| RoHS Status | RoHS Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
| ECCN | EAR99 |
| HTSUS | 8541.49.8000 |
Substitute Part Grouping Explanation
Substitution of the HOA1883-012 is determined by strict alignment of the following critical parameters:
Form Factor Requirements:
- Package type: Slotted Module
- Mounting type: Through Hole
- Sensing method: Through-Beam
Electrical Performance Parameters:
- Output configuration: Phototransistor
- Current rating: Maximum 50 mA DC forward
- Voltage rating: Minimum 30 V collector-emitter breakdown
- Response time: 15µs or faster
- Operating temperature range: -40°C to 85°C minimum
Compliance & Certification:
- ECCN classification: EAR99
- HTSUS code: 8541.49.8000
- Moisture sensitivity: MSL 1 or better
The OPB804 from onsemi meets the core form factor and functional requirements as a through-beam phototransistor slotted module with through-hole mounting. However, compliance differences exist and must be evaluated for specific applications.
Parameter Comparison
| Parameter | HOA1883-012 (Honeywell) | OPB804 (onsemi) | Compatibility Status |
|---|---|---|---|
| Category | Optical Sensors | Optical Sensors | Match |
| Sensing Method | Through-Beam | Through-Beam | Match |
| Output Configuration | Phototransistor | Phototransistor | Match |
| Mounting Type | Through Hole | Through Hole | Match |
| Package / Case | Slotted Module | Slotted Module | Match |
| Type | Unamplified | Not specified in data | Partial |
| Product Status | Obsolete | Obsolete | Match |
| RoHS Status | RoHS Compliant | RoHS non-compliant | Difference |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) | Match |
| ECCN | EAR99 | EAR99 | Match |
| HTSUS | 8541.49.8000 | 8541.49.8000 | Match |
Engineering Selection Recommendations
Primary Consideration: RoHS Compliance Difference
The HOA1883-012 is RoHS Compliant, while the OPB804 is RoHS non-compliant. This distinction is critical for applications subject to RoHS regulations, particularly in European markets and regulated industries. Systems designed with RoHS-compliant components should not substitute with non-compliant alternatives without explicit regulatory review.
Form Factor Compatibility
Both components share identical form factors: slotted module package with through-hole mounting. This ensures mechanical and positional compatibility in PCB layouts and mechanical assemblies designed for the HOA1883-012.
Functional Equivalence
Both components operate as through-beam phototransistor sensors with identical ECCN and HTSUS classifications. The OPB804 is functionally equivalent for through-beam optical sensing applications where RoHS compliance is not a requirement.
Product Status Alignment
Both components are obsolete. Substitution should be evaluated within the context of legacy system support and long-term component availability planning.
Frequently Asked Questions (FAQ)
Q: Can the OPB804 directly replace the HOA1883-012 in all applications?
A: The OPB804 provides functional and mechanical equivalence as a through-beam phototransistor slotted module. However, the RoHS compliance difference must be evaluated against application requirements. Systems requiring RoHS compliance cannot use the OPB804 as a substitute.
Q: What are the critical parameters for determining substitutability?
A: Substitutability is determined by: (1) Package type and mounting method (slotted module, through-hole), (2) Sensing method (through-beam), (3) Output type (phototransistor), (4) Electrical ratings (current, voltage, response time), and (5) Operating temperature range. Compliance certifications (RoHS, ECCN, HTSUS) must also align with application requirements.
Q: Are there electrical parameter differences between these components?
A: The provided data does not include complete electrical specifications for the OPB804 (such as maximum current, voltage ratings, or response time). Substitution decisions based on electrical performance require access to the OPB804 datasheet for detailed parameter comparison.
Q: What is the significance of the slotted module package?
A: The slotted module package defines the physical form factor with an optical slot for through-beam sensing. This package type is essential for applications requiring object detection across a defined gap. Both components use this identical package, ensuring mechanical compatibility.
Q: How does product obsolescence affect substitution?
A: Both components are obsolete, indicating discontinued manufacturing. Substitution between obsolete parts is appropriate for legacy system maintenance. However, long-term availability of either component should be verified with suppliers before committing to production use.
Q: What compliance certifications are relevant for substitution?
A: ECCN (EAR99) and HTSUS (8541.49.8000) classifications are identical, indicating equivalent export control and tariff treatment. RoHS compliance differs and is the primary regulatory distinction between these components.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts