HO 6-P Current Sensor Hall Effect Module - Equivalent & Substitute Parts

Part Overview

The HO 6-P is an active Hall Effect current sensor manufactured by LEM USA Inc., designed for AC/DC current measurement applications requiring bidirectional sensing capability. This open-loop module provides ratiometric voltage output with a 6A sensing range and operates across industrial temperature ranges. The product maintains Active status with full RoHS compliance and REACH unaffected classification. Substitute parts are identified when equivalent electrical performance and mechanical compatibility are required due to supply constraints, voltage supply requirements, or application-specific integration needs.

Substiute Parts

HO 6-P
LEM USA Inc.In Stock: 763HO 6-P Datasheet
HO 6-P
Current Part
HO 6-P/SP33
LEM USA Inc.In Stock: 1247HO 6-P/SP33 Datasheet
HO 6-P/SP33
Parametric Equivalent

Key Parameters

Parameter Value Significance for Substitution
Current Sensing Range 6A Core functional specification; must match exactly
Sensor Type Hall Effect, Open Loop Determines measurement principle and output characteristics
Number of Channels 1 Single-channel configuration; substitutes must maintain this
Output Type Ratiometric, Voltage Defines signal conditioning and interface requirements
Frequency Response DC ~ 250kHz Bandwidth specification; substitutes must meet or exceed
Linearity ±0.5% Accuracy specification; critical for measurement applications
Accuracy ±1.4% Overall measurement error; must be maintained
Voltage Supply 5V or 3.3V variants Determines circuit compatibility and power requirements
Response Time 3.5µs Dynamic performance specification
Operating Temperature -40°C ~ 105°C Environmental operating range
Polarization Bidirectional Capability to measure current in both directions
Mounting Type Through Hole PCB integration method; must match board design
Package Type Module, Single Pass Through Physical form factor and conductor configuration

Substitute Part Grouping Explanation

Substitution between HO 6-P and HO 6-P/SP33 is based on electrical and mechanical parameter equivalence within the HO-P series family. Both parts maintain identical specifications for current sensing range (6A), sensor type (Hall Effect, Open Loop), channel count (1), output type (Ratiometric Voltage), frequency response (DC ~ 250kHz), linearity (±0.5%), accuracy (±1.4%), response time (3.5µs), operating temperature range (-40°C ~ 105°C), polarization (Bidirectional), mounting type (Through Hole), and package configuration (Module, Single Pass Through).

The primary differentiator is the supply voltage specification: HO 6-P operates at 5V supply, while HO 6-P/SP33 operates at 3.3V supply. This distinction determines circuit compatibility and power delivery requirements. Both variants maintain maximum supply current of 25mA and are RoHS Compliant with REACH Unaffected status. Selection between these variants depends exclusively on the host system's available supply voltage and downstream signal processing requirements.

Parameter Comparison

Parameter HO 6-P HO 6-P/SP33 Match Status
Manufacturer LEM USA Inc. LEM USA Inc. Identical
Current Sensing 6A 6A Identical
Sensor Type Hall Effect, Open Loop Hall Effect, Open Loop Identical
Number of Channels 1 1 Identical
Output Ratiometric, Voltage Ratiometric, Voltage Identical
Frequency Response DC ~ 250kHz DC ~ 250kHz Identical
Linearity ±0.5% ±0.5% Identical
Accuracy ±1.4% ±1.4% Identical
Voltage Supply 5V 3.3V Different
Response Time 3.5µs 3.5µs Identical
Current Supply (Max) 25mA 25mA Identical
Operating Temperature -40°C ~ 105°C -40°C ~ 105°C Identical
Polarization Bidirectional Bidirectional Identical
Mounting Type Through Hole Through Hole Identical
Package Type Module, Single Pass Through Module, Single Pass Through Identical
RoHS Status RoHS Compliant RoHS Compliant Identical
REACH Status REACH Unaffected REACH Unaffected Identical
ECCN EAR99 EAR99 Identical
HTSUS Code 9030.33.3800 9030.33.3800 Identical

Engineering Selection Recommendations

Both HO 6-P and HO 6-P/SP33 are Active products with full regulatory compliance. Selection between these variants is determined by system power supply architecture:

HO 6-P (5V Supply): Select this variant for systems with 5V power rails or where 5V supply voltage is the primary available source. This configuration is suitable for standard industrial control systems and legacy designs utilizing 5V logic levels.

HO 6-P/SP33 (3.3V Supply): Select this variant for modern embedded systems, microcontroller-based designs, and applications where 3.3V supply voltage is the primary available source. This configuration is compatible with contemporary digital signal processors and low-power system architectures.

Both variants maintain identical measurement performance specifications, environmental ratings, and compliance certifications. The choice between them is purely a function of available supply voltage in the target application circuit. No performance trade-offs exist between the two variants within their respective supply voltage domains.

Frequently Asked Questions (FAQ)

Q: Can HO 6-P and HO 6-P/SP33 be used interchangeably in the same circuit?

A: No. These variants require different supply voltages (5V versus 3.3V). Direct substitution without circuit modification will result in improper sensor operation. The host system must provide the correct supply voltage for the selected variant.

Q: Are the output signal levels different between HO 6-P and HO 6-P/SP33?

A: Both variants provide ratiometric voltage output. The output signal scales proportionally to the supply voltage. HO 6-P outputs are referenced to 5V, while HO 6-P/SP33 outputs are referenced to 3.3V. Downstream signal conditioning circuits must be designed accordingly.

Q: Do both variants have identical measurement accuracy?

A: Yes. Both HO 6-P and HO 6-P/SP33 maintain ±1.4% accuracy and ±0.5% linearity specifications. Measurement performance is equivalent across both variants.

Q: What is the physical difference between these two parts?

A: Both variants use identical Through Hole mounting and Module, Single Pass Through package configuration. Physical form factor and PCB footprint are identical. The difference is internal to the sensor electronics.

Q: Are both variants RoHS compliant?

A: Yes. Both HO 6-P and HO 6-P/SP33 are RoHS Compliant and REACH Unaffected. Both meet current environmental and regulatory requirements.

Q: Can I use HO 6-P/SP33 in a 5V system?

A: No. HO 6-P/SP33 is specified for 3.3V supply voltage. Operating this variant at 5V will exceed design specifications and may cause component damage or failure.

Q: What is the current consumption difference between variants?

A: Both variants have identical maximum supply current specification of 25mA. Current consumption is equivalent.

Q: Are there any temperature rating differences?

A: No. Both variants operate across the identical temperature range of -40°C to 105°C.

Request Quote (Ships tomorrow)