Request Quote
(Ships tomorrow)
HLSR 32-SM Hall Effect Current Sensor Equivalent & Substitute Parts
Part Overview
The HLSR 32-SM is an active Hall Effect current sensor manufactured by LEM USA Inc., designed for AC/DC current measurement applications requiring open-loop bidirectional sensing. This surface-mount module sensor operates at 32A nominal sensing capacity with ratiometric voltage output and is classified as an Active product with full RoHS compliance.
Substitute parts are identified when equivalent electrical performance can be achieved within the allowed parameter tolerances for this sensor category, or when application requirements permit operation at reduced current ratings while maintaining core functional characteristics.
Substiute Parts
Key Parameters
| Parameter | Value | Unit | Substitution Relevance |
|---|---|---|---|
| Current Sensing Rating | 32A | A | Primary differentiator; determines maximum measurable current |
| Sensor Type | Hall Effect, Open Loop | — | Core technology; must match for functional equivalence |
| Output Type | Ratiometric, Voltage | — | Signal interface; must be compatible with system requirements |
| Sensitivity | 25 | mV/A | Determines output signal magnitude per ampere |
| Supply Voltage | 5V | V | Power requirement; affects circuit compatibility |
| Accuracy | ±1% | — | Measurement precision specification |
| Linearity | ±0.5% | — | Output linearity across measurement range |
| Operating Temperature | -40 to 105 | °C | Environmental operating range |
| Mounting Type | Surface Mount | — | PCB assembly compatibility |
| Polarization | Bidirectional | — | Directional current sensing capability |
Substitute Part Grouping Explanation
Substitution logic for the HLSR 32-SM is based on the following allowed parameters:
Matching Criteria (Required for Substitution):
- Sensor Type: Hall Effect, Open Loop
- Output Type: Ratiometric, Voltage
- Mounting Type: Surface Mount
- Polarization: Bidirectional
- Accuracy: ±1%
- Linearity: ±0.5%
- Operating Temperature Range: -40°C to 105°C
- Frequency Response: 400kHz
- Response Time: 2.5µs
- RoHS Compliance: Yes
- Manufacturer: LEM USA Inc.
Variable Parameters (Allowed to Differ):
- Current Sensing Rating: May be lower if application permits
- Supply Voltage: May differ if system supports alternative voltage
- Sensitivity: Varies with current rating; proportional relationship acceptable
- Maximum Supply Current: Within specified range
The HLSR 20-SM/SP33 qualifies as a parametric equivalent substitute when the application current requirement does not exceed 20A and the system power supply supports 3.3V operation.
Parameter Comparison
| Parameter | HLSR 32-SM | HLSR 20-SM/SP33 | Compatibility Notes |
|---|---|---|---|
| Manufacturer | LEM USA Inc. | LEM USA Inc. | Same manufacturer; consistent quality standards |
| Sensor Type | Hall Effect, Open Loop | Hall Effect, Open Loop | Identical technology |
| Current Sensing | 32A | 20A | HLSR 20-SM/SP33 rated for lower current; suitable for applications ≤20A |
| Output Type | Ratiometric, Voltage | Ratiometric, Voltage | Identical output interface |
| Sensitivity | 25 mV/A | 23 mV/A | Proportional to current rating; minor difference acceptable |
| Supply Voltage | 5V | 3.3V | Different supply requirement; system must support 3.3V |
| Accuracy | ±1% | ±1% | Identical specification |
| Linearity | ±0.5% | ±0.5% | Identical specification |
| Frequency | 400kHz | 400kHz | Identical bandwidth |
| Response Time | 2.5µs | 2.5µs | Identical response characteristic |
| Operating Temperature | -40 to 105°C | -40 to 105°C | Identical range |
| Polarization | Bidirectional | Bidirectional | Identical directional capability |
| Mounting Type | Surface Mount | Surface Mount | Identical PCB assembly method |
| Max Supply Current | 25mA | 25mA | Identical power consumption |
| RoHS Status | RoHS Compliant | RoHS Compliant | Both meet environmental standards |
| Product Status | Active | Active | Both actively manufactured and supported |
Engineering Selection Recommendations
HLSR 32-SM Selection Criteria:
- Applications requiring current measurement up to 32A
- Systems with 5V power supply availability
- Designs requiring maximum sensitivity at 25mV/A output
- Full-range current sensing without derating
HLSR 20-SM/SP33 Selection Criteria:
- Applications with maximum current requirement of 20A or less
- Systems with 3.3V power supply (typical in modern digital circuits)
- Designs compatible with 23mV/A sensitivity specification
- Space-constrained applications where lower current rating is acceptable
Both parts maintain identical accuracy (±1%), linearity (±0.5%), response time (2.5µs), and operating temperature range (-40°C to 105°C). Both are Active products with full RoHS compliance and REACH unaffected status. Selection between these parts is determined by application current requirements and available system supply voltage.
Frequently Asked Questions (FAQ)
Q: Can HLSR 20-SM/SP33 be used in place of HLSR 32-SM in all applications?
A: No. The HLSR 20-SM/SP33 is rated for maximum 20A sensing. It can only substitute the HLSR 32-SM when the application current requirement does not exceed 20A. Additionally, the system power supply must support 3.3V operation instead of 5V.
Q: What is the difference in sensitivity between these two sensors?
A: HLSR 32-SM provides 25mV/A sensitivity, while HLSR 20-SM/SP33 provides 23mV/A sensitivity. This difference is proportional to their respective current ratings and is within normal design tolerance for equivalent sensor families.
Q: Are both sensors compatible with the same PCB footprint?
A: Both sensors use Surface Mount packaging and are manufactured by LEM USA Inc. in the HLSR-SM series. Mechanical compatibility should be verified against specific package drawings, as the input does not provide detailed dimensional specifications.
Q: What is the impact of different supply voltages on system design?
A: The HLSR 32-SM requires 5V supply, while HLSR 20-SM/SP33 requires 3.3V supply. The choice affects power supply design and signal conditioning circuits. Both draw maximum 25mA supply current.
Q: Can these sensors measure AC and DC current?
A: Yes. Both HLSR 32-SM and HLSR 20-SM/SP33 are specified for AC/DC current measurement with bidirectional polarization, allowing measurement of current flow in both directions.
Q: Are there any compliance or certification differences between these parts?
A: No. Both parts are RoHS Compliant, REACH Unaffected, and classified under ECCN EAR99. Both maintain Active product status with identical environmental and regulatory compliance.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts