Request Quote
(Ships tomorrow)
HG2-AC48V Equivalent & Substitute Parts
Part Overview
The HG2-AC48V is a general purpose relay manufactured by Panasonic Electric Works, featuring a DPDT (2 Form C) contact configuration with a 48VAC coil and 20A contact rating. This socketable relay is designed for industrial control applications requiring reliable switching at 250VAC nominal switching voltage. The product is currently obsolete, making identification of compatible substitute parts essential for system maintenance and component replacement in existing installations.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | HG2-AC48V |
| Manufacturer | Panasonic Electric Works |
| Coil Voltage | 48VAC |
| Contact Form | DPDT (2 Form C) |
| Contact Rating (Current) | 20 A |
| Switching Voltage | 250VAC - Nom |
| Mounting Type | Socketable |
| Termination Style | Plug In, Quick Connect - 0.250" (6.3mm) |
| Coil Current | 75 mA |
| Must Operate Voltage | 38.4 VAC |
| Must Release Voltage | 14.4 VAC |
| Operating Temperature Range | -50°C ~ 40°C |
| Product Status | Obsolete |
Substitute Part Grouping Explanation
Substitution of the HG2-AC48V is determined by the following critical parameters that must remain consistent:
- Coil Voltage: 48VAC (exact match required)
- Contact Form: DPDT (2 Form C) configuration (exact match required)
- Mounting Type: Socketable with plug-in termination (exact match required)
- Must Operate Voltage: 38.4 VAC (exact match required)
- Must Release Voltage: 14.4 VAC (exact match required)
The LY2 AC48 from Omron Automation and Safety meets these core substitution criteria. However, the contact rating differs: the HG2-AC48V is rated for 20A, while the LY2 AC48 is rated for 10A. This difference must be evaluated against the specific application requirements.
Parameter Comparison
| Parameter | HG2-AC48V (Panasonic) | LY2 AC48 (Omron) |
|---|---|---|
| Coil Voltage | 48VAC | 48VAC |
| Contact Form | DPDT (2 Form C) | DPDT (2 Form C) |
| Contact Rating (Current) | 20 A | 10 A |
| Switching Voltage | 250VAC - Nom | 250VAC, 125VDC - Max |
| Mounting Type | Socketable | Socketable |
| Termination Style | Plug In, Quick Connect - 0.250" (6.3mm) | Plug In |
| Coil Current | 75 mA | 23 mA |
| Must Operate Voltage | 38.4 VAC | 38.4 VAC |
| Must Release Voltage | 14.4 VAC | 14.4 VAC |
| Operate Time | 15 ms | 25 ms |
| Release Time | 15 ms | 25 ms |
| Operating Temperature Range | -50°C ~ 40°C | -25°C ~ 55°C |
| Product Status | Obsolete | Active |
| RoHS Status | Not specified | RoHS Compliant |
Engineering Selection Recommendations
The LY2 AC48 is the identified substitute for the obsolete HG2-AC48V based on matching coil voltage, contact form, mounting configuration, and voltage thresholds. The LY2 AC48 is currently in active production status with RoHS compliance certification, ensuring long-term availability and regulatory alignment.
Selection of the LY2 AC48 requires verification that the 10A contact rating is sufficient for the application, as this represents a reduction from the original 20A specification. The lower coil current (23 mA versus 75 mA) and extended operating temperature range (-25°C ~ 55°C) of the LY2 AC48 may provide operational advantages in certain installations. The slightly longer switching times (25 ms versus 15 ms) must be evaluated against application timing requirements.
Frequently Asked Questions (FAQ)
Q: Can the LY2 AC48 directly replace the HG2-AC48V in all applications?
A: The LY2 AC48 matches the critical electrical parameters (coil voltage, contact form, voltage thresholds) and mounting configuration. However, the contact rating is reduced from 20A to 10A. Direct replacement is only appropriate if the application current does not exceed 10A.
Q: What is the significance of the different contact ratings?
A: The HG2-AC48V is rated for 20A switching current, while the LY2 AC48 is rated for 10A. The contact rating defines the maximum continuous current the relay contacts can safely switch. Exceeding this rating may result in contact degradation or failure.
Q: Are the switching times compatible?
A: The HG2-AC48V operates and releases in 15 ms, while the LY2 AC48 requires 25 ms for both operations. Applications
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts