HCPL-4506#360 Equivalent & Substitute Parts

Part Overview

The HCPL-4506#360 is a Logic Output Optoisolator with Open Collector, Schottky Clamped output configuration manufactured by Broadcom Limited. This component provides galvanic isolation up to 3750Vrms with a single channel design, suitable for applications requiring high-speed signal isolation in industrial and power management circuits. The part is currently Active in product status. Identifying equivalent and substitute parts is necessary to ensure design flexibility, manage supply chain continuity, and accommodate varying compliance requirements across different manufacturing batches and regional specifications.

Substiute Parts

HCPL-4506#360
Broadcom LimitedIn Stock: 1228HCPL-4506#360 Datasheet
HCPL-4506#360
Current Part
HCPL-4506-360E
Broadcom LimitedIn Stock: 5871HCPL-4506-360E Datasheet
HCPL-4506-360E
Direct

Key Parameters

Parameter Value
Manufacturer Broadcom Limited
Category Optoisolators
Number of Channels 1
Voltage - Isolation 3750Vrms
Common Mode Transient Immunity (Min) 15kV/µs
Input Type DC
Output Type Open Collector, Schottky Clamped
Current - Output / Channel 15 mA
Propagation Delay tpLH / tpHL (Max) 550ns, 400ns
Voltage - Forward (Vf) (Typ) 1.5V
Current - DC Forward (If) (Max) 25mA
Voltage - Supply 4.5V ~ 30V
Operating Temperature -40°C ~ 100°C
Package / Case 8-SMD, Gull Wing
Mounting Type Surface Mount
Moisture Sensitivity Level (MSL) 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution eligibility for the HCPL-4506#360 is determined by strict equivalence across the following critical parameters:

  • Manufacturer: Broadcom Limited (same manufacturer ensures design consistency)
  • Number of Channels: 1 (functional requirement)
  • Voltage - Isolation: 3750Vrms (isolation specification)
  • Common Mode Transient Immunity (Min): 15kV/µs (signal integrity requirement)
  • Input Type: DC (input signal specification)
  • Output Type: Open Collector, Schottky Clamped (output configuration)
  • Current - Output / Channel: 15 mA (load driving capability)
  • Propagation Delay tpLH / tpHL (Max): 550ns, 400ns (timing specification)
  • Voltage - Forward (Vf) (Typ): 1.5V (LED forward voltage)
  • Current - DC Forward (If) (Max): 25mA (LED current rating)
  • Voltage - Supply: 4.5V ~ 30V (power supply range)
  • Operating Temperature: -40°C ~ 100°C (thermal operating range)
  • Package / Case: 8-SMD, Gull Wing (physical and electrical interface)

The substitute part HCPL-4506-360E meets all these criteria and is manufactured by the same supplier, ensuring pin-compatible and functionally equivalent operation.

Parameter Comparison

Parameter HCPL-4506#360 HCPL-4506-360E Match
Manufacturer Broadcom Limited Broadcom Limited
Category Optoisolators Optoisolators
Number of Channels 1 1
Voltage - Isolation 3750Vrms 3750Vrms
Common Mode Transient Immunity (Min) 15kV/µs 15kV/µs
Input Type DC DC
Output Type Open Collector, Schottky Clamped Open Collector, Schottky Clamped
Current - Output / Channel 15 mA 15 mA
Propagation Delay tpLH / tpHL (Max) 550ns, 400ns 550ns, 400ns
Voltage - Forward (Vf) (Typ) 1.5V 1.5V
Current - DC Forward (If) (Max) 25mA 25mA
Voltage - Supply 4.5V ~ 30V 4.5V ~ 30V
Operating Temperature -40°C ~ 100°C -40°C ~ 100°C
Package / Case 8-SMD, Gull Wing 8-SMD, Gull Wing
Mounting Type Surface Mount Surface Mount
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)
Product Status Active Active
RoHS Status RoHS non-compliant ROHS3 Compliant Differs

Engineering Selection Recommendations

Both HCPL-4506#360 and HCPL-4506-360E are functionally equivalent optoisolators with identical electrical and mechanical specifications. The primary distinction lies in regulatory compliance status.

HCPL-4506#360 is RoHS non-compliant, while HCPL-4506-360E is ROHS3 compliant. For applications subject to RoHS3 regulations or requiring compliance documentation, HCPL-4506-360E is the appropriate selection. Both parts maintain REACH Unaffected status and carry the same ECCN and HTSUS classifications.

Both components are Active products with unlimited moisture sensitivity level (MSL 1), ensuring consistent long-term availability and handling requirements. Selection between these parts should be based on the specific regulatory requirements of the target application and regional market.

Frequently Asked Questions (FAQ)

Q: Are HCPL-4506#360 and HCPL-4506-360E pin-compatible?

A: Yes. Both parts use the 8-SMD Gull Wing package configuration with identical pinout and electrical interface specifications.

Q: What is the primary difference between these two parts?

A: The HCPL-4506-360E is ROHS3 compliant, while the HCPL-4506#360 is RoHS non-compliant. All electrical and mechanical parameters are identical.

Q: Can I substitute HCPL-4506-360E for HCPL-4506#360 in existing designs?

A: Yes, the HCPL-4506-360E is a direct functional equivalent with identical isolation voltage (3750Vrms), CMTI (15kV/µs), output current (15 mA), propagation delay (550ns/400ns), and operating temperature range (-40°C to 100°C).

Q: Which part should I select for new designs?

A: Selection depends on regulatory requirements. For applications requiring RoHS3 compliance, use HCPL-4506-360E. For applications without RoHS compliance mandates, either part is functionally suitable.

Q: Are there any differences in supply voltage or operating temperature?

A: No. Both parts operate across the same supply voltage range (4.5V to 30V) and temperature range (-40°C to 100°C).

Q: What is the moisture sensitivity level for both parts?

A: Both HCPL-4506#360 and HCPL-4506-360E carry MSL 1 (Unlimited), indicating no moisture sensitivity restrictions during storage or handling.