HCPL3700 Optoisolator Darlington Output Equivalent & Substitute Parts

Part Overview

The HCPL3700 is a 2500Vrms optoisolator with Darlington output in 8-DIP through-hole packaging manufactured by onsemi. This component is classified as obsolete, necessitating identification of active equivalent and substitute parts for new designs and ongoing production requirements. Substitute parts must maintain functional compatibility across isolation voltage, output characteristics, channel configuration, and package specifications.

Substiute Parts

HCPL3700
onsemiIn Stock: 3360HCPL3700 Datasheet
HCPL3700
Current Part
HCPL3700M
onsemiIn Stock: 143338HCPL3700M Datasheet
HCPL3700M
MFR Recommended
HCPL-3700
Broadcom LimitedIn Stock: 2139HCPL-3700 Datasheet
HCPL-3700
Similar
HCPL-3700-000E
Broadcom LimitedIn Stock: 1726HCPL-3700-000E Datasheet
HCPL-3700-000E
Similar
HCPL-3700-020E
Broadcom LimitedIn Stock: 6102HCPL-3700-020E Datasheet
HCPL-3700-020E
Similar
HCPL-3760
Broadcom LimitedIn Stock: 4215HCPL-3760 Datasheet
HCPL-3760
Similar
HCPL-3760-000E
Broadcom LimitedIn Stock: 9562HCPL-3760-000E Datasheet
HCPL-3760-000E
Similar
HCPL-3760-060E
Broadcom LimitedIn Stock: 859HCPL-3760-060E Datasheet
HCPL-3760-060E
Similar

Key Parameters

Parameter HCPL3700
Manufacturer onsemi
Product Status Obsolete
Number of Channels 1
Voltage - Isolation 2500Vrms
Output Type Darlington
Voltage - Output (Max) 20V
Current - Output / Channel 30mA
Turn On / Turn Off Time (Typ) 6µs, 25µs
Rise / Fall Time (Typ) 45µs, 0.5µs
Input Type AC, DC
Operating Temperature -40°C ~ 85°C
Mounting Type Through Hole
Package / Case 8-DIP (0.300", 7.62mm)
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitute parts for the HCPL3700 are grouped based on the following critical parameters that determine functional compatibility:

Primary Compatibility Criteria:

  • Single channel configuration (1 channel)
  • Darlington output type
  • 8-DIP through-hole package (0.300", 7.62mm)
  • AC/DC input capability
  • 20V maximum output voltage
  • 30mA output current per channel
  • Operating temperature range -40°C to 85°C

Isolation Voltage Consideration: Substitute parts with equal or higher isolation voltage ratings (2500Vrms or greater) are functionally compatible. Parts with lower isolation voltage ratings do not meet minimum substitution requirements.

Timing Characteristics: Turn-on/turn-off times and rise/fall times vary among substitutes but do not prevent functional substitution when other parameters align.

Parameter Comparison

Parameter HCPL3700 (onsemi) HCPL3700M (onsemi) HCPL-3700 (Broadcom) HCPL-3700-000E (Broadcom) HCPL-3700-020E (Broadcom) HCPL-3760 (Broadcom) HCPL-3760-000E (Broadcom) HCPL-3760-060E (Broadcom)
Manufacturer onsemi onsemi Broadcom Limited Broadcom Limited Broadcom Limited Broadcom Limited Broadcom Limited Broadcom Limited
Product Status Obsolete Active Active Active Active Active Active Active
Number of Channels 1 1 1 1 1 1 1 1
Voltage - Isolation 2500Vrms 5000Vrms 3750Vrms 3750Vrms 5000Vrms 3750Vrms 3750Vrms 3750Vrms
Output Type Darlington Darlington Darlington Darlington Darlington Darlington Darlington Darlington
Voltage - Output (Max) 20V 20V 20V 20V 20V 20V 20V 20V
Current - Output / Channel 30mA 30mA 30mA 30mA 30mA 30mA 30mA 30mA
Turn On / Turn Off Time (Typ) 6µs, 25µs 6µs, 25µs 4µs, 10µs 4µs, 10µs 4µs, 10µs 4.5µs, 8µs 4.5µs, 8µs 4.5µs, 8µs
Rise / Fall Time (Typ) 45µs, 0.5µs 45µs, 0.5µs 20µs, 0.3µs 20µs, 0.3µs 20µs, 0.3µs 14µs, 0.4µs 14µs, 0.4µs 14µs, 0.4µs
Input Type AC, DC AC, DC AC, DC AC, DC AC, DC AC, DC AC, DC AC, DC
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C -40°C ~ 85°C -40°C ~ 85°C -40°C ~ 85°C -40°C ~ 85°C -40°C ~ 85°C -40°C ~ 85°C
Mounting Type Through Hole Through Hole Through Hole Through Hole Through Hole Through Hole Through Hole Through Hole
Package / Case 8-DIP (0.300", 7.62mm) 8-DIP (0.300", 7.62mm) 8-DIP (0.300", 7.62mm) 8-DIP (0.300", 7.62mm) 8-DIP (0.300", 7.62mm) 8-DIP (0.300", 7.62mm) 8-DIP (0.300", 7.62mm) 8-DIP (0.300", 7.62mm)
RoHS Status ROHS3 Compliant ROHS3 Compliant RoHS non-compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant

Engineering Selection Recommendations

Primary Recommendation - MFR Recommended Substitute: HCPL3700M (onsemi) is the manufacturer-recommended substitute. This part maintains identical electrical and timing characteristics to the original HCPL3700 while offering active product status and higher isolation voltage (5000Vrms). ROHS3 compliance is maintained.

Alternative Substitutes - Broadcom Limited Parts: All Broadcom Limited optoisolators listed (HCPL-3700, HCPL-3700-000E, HCPL-3700-020E, HCPL-3760, HCPL-3760-000E, HCPL-3760-060E) meet core functional requirements with identical channel count, output type, voltage ratings, current capacity, and package specifications. All maintain active product status.

Compliance Considerations:

  • HCPL3700M, HCPL-3700-000E, HCPL-3700-020E, HCPL-3760, HCPL-3760-000E, and HCPL-3760-060E are ROHS3 compliant.
  • HCPL-3700 (Broadcom) is RoHS non-compliant and should be avoided in applications requiring RoHS compliance.

Timing Performance: Broadcom parts exhibit faster switching characteristics (4µs to 4.5µs turn-on time versus 6µs for onsemi parts). This represents an improvement in switching speed and does not create compatibility issues in standard applications.

Frequently Asked Questions (FAQ)

Q: Can HCPL3700M directly replace HCPL3700 in existing designs? A: Yes. HCPL3700M is the onsemi manufacturer-recommended substitute with identical pin configuration, package, and electrical characteristics. The higher isolation voltage (5000Vrms versus 2500Vrms) provides additional safety margin without affecting circuit operation.

Q: Are Broadcom optoisolators compatible with HCPL3700 designs? A: Yes. All listed Broadcom parts (HCPL-3700 series and HCPL-3760 series) maintain identical channel count, output type, voltage ratings, current capacity, and 8-DIP package specifications. Pin-for-pin compatibility is maintained across all substitutes.

Q: What is the difference between HCPL-3700 and HCPL-3760 variants? A: Both series provide 3750Vrms isolation voltage and identical output specifications. The HCPL-3760 series exhibits slightly faster switching times (4.5µs turn-on versus 4µs for HCPL-3700 series) and faster rise/fall times (14µs/0.4µs versus 20µs/0.3µs). Functional substitution is direct.

Q: Does the "-000E" or "-020E" suffix affect substitution compatibility? A: No. These suffixes denote packaging variants and internal configuration codes. All parts with the same base number (HCPL-3700 or HCPL-3760) are functionally equivalent for substitution purposes.

Q: Which substitute should be selected for RoHS-compliant applications? A: HCPL3700M (onsemi), HCPL-3700-000E, HCPL-3700-020E, HCPL-3760, HCPL-3760-000E, and HCPL-3760-060E are all ROHS3 compliant. Avoid HCPL-3700 (Broadcom) in RoHS-regulated applications.

Q: Are there inventory considerations for substitute selection? A: HCPL3700M offers the highest inventory availability (143,290 pcs). HCPL-3760-000E provides 9,500 pcs, and HCPL-3700-020E provides 6,000 pcs. Original HCPL3700 inventory is limited (3,300 pcs).

Q: Do timing differences between substitutes affect circuit performance? A: Broadcom parts exhibit faster switching characteristics than the original onsemi HCPL3700. In standard applications, faster switching represents an improvement. Applications with specific timing requirements should verify compatibility with datasheet specifications.

Request Quote (Ships tomorrow)