HCPL-3100-300E Equivalent & Substitute Parts

Part Overview

The HCPL-3100-300E is a 600mA gate driver optical coupler manufactured by Broadcom Limited, designed for high-voltage isolation applications requiring 5000Vrms isolation rating. This component features 1-channel optical coupling technology in an 8-DIP gull wing surface mount package. The product is currently classified as obsolete, making identification of suitable substitute components essential for ongoing system support and new design implementations.

Substiute Parts

HCPL-3100-300E
Broadcom LimitedIn Stock: 751HCPL-3100-300E Datasheet
HCPL-3100-300E
Current Part
HCPL-3150-300E
Broadcom LimitedIn Stock: 80484HCPL-3150-300E Datasheet
HCPL-3150-300E
MFR Recommended

Key Parameters

Parameter Value
Manufacturer Part Number HCPL-3100-300E
Manufacturer Broadcom Limited
Technology Optical Coupling
Number of Channels 1
Voltage - Isolation 5000Vrms
Common Mode Transient Immunity (Min) 15kV/µs
Propagation Delay tpLH / tpHL (Max) 2µs, 2µs
Rise / Fall Time (Typ) 200ns, 200ns
Current - Peak Output 600mA
Voltage - Forward (Vf) (Typ) 1.2V
Current - DC Forward (If) (Max) 25 mA
Voltage - Output Supply 15V ~ 30V
Operating Temperature -40°C ~ 100°C
Package / Case 8-SMD, Gull Wing
Product Status Obsolete
Moisture Sensitivity Level (MSL) 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution of the HCPL-3100-300E is determined by the following critical parameters:

  • Isolation Voltage Rating: The HCPL-3100-300E specifies 5000Vrms isolation. Substitute components must maintain isolation voltage at or above this level to preserve system safety margins.
  • Channel Configuration: Single-channel optical coupling architecture must be preserved.
  • Output Current Capability: Peak output current of 600mA establishes the minimum drive capability requirement.
  • Common Mode Transient Immunity: 15kV/µs minimum CMTI ensures adequate performance in high-speed switching environments.
  • Package Compatibility: 8-DIP gull wing surface mount package must be maintained for PCB layout compatibility.
  • Operating Temperature Range: -40°C to 100°C operating window must be supported.
  • Output Supply Voltage: 15V to 30V supply range compatibility is required.

The HCPL-3150-300E qualifies as a substitute based on these parameters, though with specific trade-offs in isolation voltage and timing characteristics.

Parameter Comparison

Parameter HCPL-3100-300E (Main Part) HCPL-3150-300E (Substitute)
Manufacturer Broadcom Limited Broadcom Limited
Technology Optical Coupling Optical Coupling
Number of Channels 1 1
Voltage - Isolation 5000Vrms 3750Vrms
Common Mode Transient Immunity (Min) 15kV/µs 15kV/µs
Propagation Delay tpLH / tpHL (Max) 2µs, 2µs 500ns, 500ns
Pulse Width Distortion (Max) Not specified 300ns
Rise / Fall Time (Typ) 200ns, 200ns 100ns, 100ns
Current - Peak Output 600mA 600mA
Voltage - Forward (Vf) (Typ) 1.2V 1.5V
Current - DC Forward (If) (Max) 25 mA 25 mA
Voltage - Output Supply 15V ~ 30V 15V ~ 30V
Operating Temperature -40°C ~ 100°C -40°C ~ 100°C
Package / Case 8-SMD, Gull Wing 8-SMD, Gull Wing
Product Status Obsolete Active
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)

Engineering Selection Recommendations

The HCPL-3150-300E is the manufacturer-recommended substitute for the obsolete HCPL-3100-300E. Both components are manufactured by Broadcom Limited and share identical package geometry, channel configuration, and output supply voltage specifications.

Key considerations for substitution:

Isolation Voltage Trade-off: The HCPL-3150-300E provides 3750Vrms isolation versus the original 5000Vrms specification. This represents a 25% reduction in isolation voltage rating. Substitution is appropriate only when system isolation requirements do not exceed 3750Vrms.

Timing Performance Improvement: The HCPL-3150-300E demonstrates superior timing characteristics with propagation delay of 500ns (versus 2µs), rise/fall times of 100ns (versus 200ns), and specified pulse width distortion of 300ns. These improvements may benefit high-frequency switching applications.

Compliance and Availability: The HCPL-3150-300E maintains active product status with ROHS3 compliance and significantly higher inventory availability (80,400 units versus 692 units for the obsolete part). Both components carry identical approval agencies (UR for the main part; CSA and UR for the substitute) and REACH unaffected status.

Forward Voltage Consideration: The HCPL-3150-300E exhibits a typical forward voltage of 1.5V compared to 1.2V for the HCPL-3100-300E, representing a 0.3V increase in LED forward voltage drop.

Frequently Asked Questions (FAQ)

Q: Can the HCPL-3150-300E directly replace the HCPL-3100-300E in existing designs?

A: Direct replacement is possible from a package and pinout perspective. However, the reduced isolation voltage rating (3750Vrms versus 5000Vrms) must be evaluated against your system's isolation requirements. If your application requires 5000Vrms isolation, the HCPL-3150-300E is not suitable.

Q: What is the primary difference between these two parts?

A: The main difference is isolation voltage rating. The HCPL-3100-300E provides 5000Vrms isolation, while the HCPL-3150-300E provides 3750Vrms isolation. The HCPL-3150-300E offers faster propagation delay and rise/fall times.

Q: Are both parts pin-compatible?

A: Yes. Both components use the 8-DIP gull wing surface mount package with identical pinout and electrical interface specifications for the output supply voltage range (15V to 30V).

Q: Why is the HCPL-3100-300E obsolete?

A: The HCPL-3100-300E is classified as obsolete by the manufacturer. The HCPL-3150-300E is the active product line replacement, offering improved performance characteristics and continued manufacturing support.

Q: Does the higher forward voltage of the HCPL-3150-300E affect circuit design?

A: The 0.3V increase in typical forward voltage (from 1.2V to 1.5V) may require input circuit adjustment if your design operates at the minimum input current specification. Both parts maintain the same maximum DC forward current of 25mA.

Q: What certifications do these parts carry?

A: The HCPL-3100-300E carries UR approval. The HCPL-3150-300E carries both CSA and UR approvals. Both are REACH unaffected and carry MSL 1 (unlimited) moisture sensitivity rating.

Request Quote (Ships tomorrow)