Request Quote
(Ships tomorrow)
HCPL-3000-300E Equivalent & Substitute Parts
Part Overview
The HCPL-3000-300E is an optoisolator power transistor driver manufactured by Broadcom Limited, designed for high-voltage isolation applications requiring 5000Vrms isolation rating. This component features a single channel configuration with 500-600mA output current capability and is packaged in an 8-SMD Gull Wing surface mount format.
The HCPL-3000-300E is classified as obsolete. Identifying suitable substitute components is necessary to maintain design continuity, ensure supply chain reliability, and support ongoing production requirements for applications currently utilizing this part.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | HCPL-3000-300E |
| Manufacturer | Broadcom Limited |
| Product Status | Obsolete |
| Type | Power Transistor Driver |
| Number of Channels | 1 |
| Voltage - Isolation | 5000Vrms |
| Common Mode Transient Immunity (Min) | 10kV/µs |
| Current - Output / Channel | 500mA, 600mA |
| Voltage - Supply | 5.4V ~ 13V |
| Operating Temperature | -20°C ~ 80°C |
| Package / Case | 8-SMD, Gull Wing |
| Mounting Type | Surface Mount |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitution eligibility for the HCPL-3000-300E is determined by the following critical parameters:
- Isolation Voltage Rating: The substitute must maintain isolation capability at or above 5000Vrms to preserve electrical safety margins in high-voltage isolation applications.
- Number of Channels: Single-channel configuration is required to match the original design.
- Package Type: 8-SMD Gull Wing surface mount packaging ensures mechanical and electrical compatibility with existing PCB layouts.
- Output Current Capability: The substitute must support the required output current range (500-600mA minimum).
- Common Mode Transient Immunity: Minimum 10kV/µs is required for reliable operation in switching environments.
The HCPL-3120-300E qualifies as a substitute based on these parameters, though with notable differences in isolation voltage rating and output current specifications that must be evaluated for specific application requirements.
Parameter Comparison
| Parameter | HCPL-3000-300E (Main Part) | HCPL-3120-300E (Substitute) |
|---|---|---|
| Manufacturer | Broadcom Limited | Broadcom Limited |
| Product Status | Obsolete | Active |
| Number of Channels | 1 | 1 |
| Voltage - Isolation | 5000Vrms | 3750Vrms |
| Common Mode Transient Immunity (Min) | 10kV/µs | 25kV/µs |
| Current - Output / Channel | 500mA, 600mA | 2A (High), 2A (Low) |
| Current - Peak Output | Not specified | 2.5A |
| Propagation Delay tpLH / tpHL (Max) | 5µs, 5µs | 500ns, 500ns |
| Voltage - Forward (Vf) (Typ) | 1.1V | 1.5V |
| Current - DC Forward (If) (Max) | 25mA | 25mA |
| Voltage - Supply | 5.4V ~ 13V | 15V ~ 30V |
| Operating Temperature | -20°C ~ 80°C | -40°C ~ 100°C |
| Package / Case | 8-SMD, Gull Wing | 8-SMD, Gull Wing |
| Mounting Type | Surface Mount | Surface Mount |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) |
| RoHS Status | Not specified | ROHS3 Compliant |
| Approval Agency | UR | CSA, UR |
Engineering Selection Recommendations
The HCPL-3120-300E is available as an active product from Broadcom Limited with current manufacturing support, addressing the obsolescence status of the HCPL-3000-300E. Both components share identical package configurations (8-SMD Gull Wing) and single-channel architecture, enabling direct PCB layout compatibility.
Key considerations for substitution:
- Isolation Voltage: The HCPL-3120-300E provides 3750Vrms isolation versus 5000Vrms for the original part. Applications requiring the full 5000Vrms isolation margin must evaluate whether the reduced rating is acceptable for their specific voltage environment.
- Supply Voltage Range: The substitute operates at 15V ~ 30V versus 5.4V ~ 13V for the original. Power supply redesign may be required.
- Output Current: The HCPL-3120-300E delivers 2A continuous output current, exceeding the 500-600mA specification of the HCPL-3000-300E, providing additional design margin.
- Propagation Delay: The substitute exhibits significantly faster propagation delay (500ns versus 5µs), which may require timing verification in delay-sensitive applications.
- Compliance: The HCPL-3120-300E carries ROHS3 compliance and dual agency approval (CSA, UR), supporting modern regulatory requirements.
Frequently Asked Questions (FAQ)
Q: Can the HCPL-3120-300E be used as a direct replacement for the HCPL-3000-300E?
A: Physical and electrical compatibility exists due to matching package type (8-SMD Gull Wing) and single-channel configuration. However, differences in isolation voltage rating (3750Vrms vs. 5000Vrms), supply voltage range (15V-30V vs. 5.4V-13V), and propagation delay (500ns vs. 5µs) require application-specific evaluation before substitution.
Q: What is the impact of the lower isolation voltage rating on substitution?
A: The HCPL-3120-300E provides 3750Vrms isolation compared to 5000Vrms for the original part. Applications operating at voltages below 3750Vrms can proceed with substitution. Applications requiring the full 5000Vrms isolation margin must retain the original part or identify alternative solutions with equivalent isolation ratings.
Q: Are there supply voltage compatibility issues?
A: Yes. The HCPL-3120-300E requires 15V ~ 30V supply voltage, while the HCPL-3000-300E operates at 5.4V ~ 13V. Existing power supply designs must be modified to accommodate the higher voltage requirement of the substitute.
Q: How does the faster propagation delay affect circuit operation?
A: The HCPL-3120-300E exhibits 500ns propagation delay versus 5µs for the original part. In timing-critical applications, this 10x improvement may alter circuit behavior. Timing analysis and functional verification are necessary to confirm compatibility with existing system timing requirements.
Q: Are both parts available in the same package configuration?
A: Yes. Both the HCPL-3000-300E and HCPL-3120-300E use 8-SMD Gull Wing surface mount packaging, ensuring identical PCB footprint compatibility and assembly process compatibility.
Q: What regulatory compliance differences exist between these parts?
A: The HCPL-3120-300E is ROHS3 compliant with dual agency approval (CSA, UR), while the HCPL-3000-300E carries UR approval only. The substitute meets current regulatory standards for new designs and manufacturing environments.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts