Part Overview
The HCPL-2202 is a logic output optoisolator manufactured by Broadcom Limited, designed for high-speed digital isolation applications. This 3.75kV isolation rated component features push-pull totem pole output configuration with 5MBd data rate capability and 1kV/µs common mode transient immunity. The device is currently in active production status and widely used in industrial control, power management, and communication interface circuits requiring galvanic isolation between logic domains.
Substitute parts are identified when equivalent electrical performance, mechanical compatibility, and functional characteristics are maintained across the specified parameter set. The primary substitute variant addresses compliance requirements while maintaining identical electrical specifications.
Substiute Parts
Key Parameters
| Parameter | Value | Unit |
|---|---|---|
| Isolation Voltage | 3750 | Vrms |
| Number of Channels | 1 | — |
| Output Type | Push-Pull, Totem Pole | — |
| Output Current per Channel | 25 | mA |
| Data Rate | 5 | MBd |
| Common Mode Transient Immunity (Min) | 1 | kV/µs |
| Propagation Delay tpLH / tpHL (Max) | 300 / 300 | ns |
| Rise / Fall Time (Typ) | 30 / 7 | ns |
| Supply Voltage Range | 4.5 – 20 | V |
| Operating Temperature Range | −40 to +85 | °C |
| Package Type | 8-DIP (0.300", 7.62mm) | — |
| Mounting Type | Through Hole | — |
Substitute Part Grouping Explanation
Substitution eligibility for the HCPL-2202 optoisolator is determined by strict equivalence across the following critical parameters:
- Isolation Voltage Rating: 3750Vrms minimum
- Channel Configuration: Single channel, 1 input / 0 feedback inputs
- Output Architecture: Push-pull totem pole configuration
- Output Current Capability: 25mA per channel minimum
- Data Rate: 5MBd minimum
- Common Mode Transient Immunity: 1kV/µs minimum
- Propagation Delay: 300ns maximum (both tpLH and tpHL)
- Package Footprint: 8-DIP (0.300", 7.62mm) through-hole mounting
- Supply Voltage Compatibility: 4.5V to 20V operation
- Temperature Range: −40°C to +85°C minimum
The identified substitute maintains all electrical specifications, mechanical dimensions, and functional characteristics. Variations in product status and compliance certifications do not affect electrical or mechanical interchangeability.
Parameter Comparison
| Parameter | HCPL-2202 | HCPL-2202-000E | Match |
|---|---|---|---|
| Manufacturer | Broadcom Limited | Broadcom Limited | ✓ |
| Category | Optoisolators | Optoisolators | ✓ |
| Number of Channels | 1 | 1 | ✓ |
| Isolation Voltage | 3750Vrms | 3750Vrms | ✓ |
| Common Mode Transient Immunity (Min) | 1kV/µs | 1kV/µs | ✓ |
| Input Type | DC | DC | ✓ |
| Output Type | Push-Pull, Totem Pole | Push-Pull, Totem Pole | ✓ |
| Output Current per Channel | 25mA | 25mA | ✓ |
| Data Rate | 5MBd | 5MBd | ✓ |
| Propagation Delay tpLH (Max) | 300ns | 300ns | ✓ |
| Propagation Delay tpHL (Max) | 300ns | 300ns | ✓ |
| Rise Time (Typ) | 30ns | 30ns | ✓ |
| Fall Time (Typ) | 7ns | 7ns | ✓ |
| Forward Voltage Vf (Typ) | 1.5V | 1.5V | ✓ |
| DC Forward Current If (Max) | 10mA | 10mA | ✓ |
| Supply Voltage Range | 4.5V – 20V | 4.5V – 20V | ✓ |
| Operating Temperature Range | −40°C to +85°C | −40°C to +85°C | ✓ |
| Package / Case | 8-DIP (0.300", 7.62mm) | 8-DIP (0.300", 7.62mm) | ✓ |
| Mounting Type | Through Hole | Through Hole | ✓ |
| Product Status | Active | Active | ✓ |
| RoHS Status | RoHS non-compliant | ROHS3 Compliant | — |
Engineering Selection Recommendations
Both HCPL-2202 and HCPL-2202-000E are active production components from Broadcom Limited with identical electrical and mechanical specifications. Selection between these variants is determined by regulatory and compliance requirements:
HCPL-2202: Suitable for applications where RoHS compliance is not mandated. Maintains full electrical performance and availability in high inventory quantities (4680 pcs).
HCPL-2202-000E: Required for applications subject to ROHS3 compliance regulations. Provides equivalent electrical performance with compliant material composition. Current inventory: 2214 pcs.
Both variants operate across the identical temperature range (−40°C to +85°C), support the same supply voltage window (4.5V to 20V), and deliver equivalent timing characteristics. Pin-for-pin compatibility and footprint equivalence enable direct substitution in PCB designs without layout modifications.
Frequently Asked Questions (FAQ)
Q: Can HCPL-2202-000E replace HCPL-2202 in existing designs?
A: Yes. The HCPL-2202-000E is electrically and mechanically equivalent to HCPL-2202. All electrical parameters, timing specifications, output characteristics, and package dimensions are identical. Direct substitution is possible without circuit modifications.
Q: What is the difference between HCPL-2202 and HCPL-2202-000E?
A: The primary difference is RoHS compliance status. HCPL-2202-000E meets ROHS3 requirements, while HCPL-2202 is RoHS non-compliant. Electrical performance, isolation voltage, data rate, output current, and all timing parameters are identical.
Q: Are both parts pin-compatible?
A: Yes. Both components use the 8-DIP (0.300", 7.62mm) through-hole package with identical pin assignments. PCB layouts require no modification for substitution.
Q: Which variant should I select for new designs?
A: Selection depends on regulatory requirements. For applications requiring ROHS3 compliance, specify HCPL-2202-000E. For applications without RoHS mandates, either variant is acceptable based on availability and cost considerations.
Q: Can these parts be used interchangeably in high-speed isolation circuits?
A: Yes. Both variants maintain 5MBd data rate capability, 300ns maximum propagation delay, and 1kV/µs common mode transient immunity. Timing-critical applications can use either part without performance degradation.
Q: What is the operating temperature range for both parts?
A: Both HCPL-2202 and HCPL-2202-000E operate across −40°C to +85°C. Temperature performance is identical between variants.
Q: Are there any supply voltage differences between the two parts?
A: No. Both variants operate across the identical 4.5V to 20V supply voltage range with equivalent performance across the full range.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts