Part Overview

The HC4E-L-DC100V-D is a general purpose 4PDT relay manufactured by Panasonic Electric Works, designed for socketable mounting with a 100VDC coil. This relay features a 4 Form C contact configuration rated for 2A switching capacity at 250VAC maximum, with integrated lighted indicator functionality. The product is currently obsolete, making identification of compatible substitute components essential for system maintenance, repair, and redesign applications where this relay is specified in legacy equipment.

Substiute Parts

HC4E-L-DC100V-D
Panasonic Electric WorksIn Stock: 698HC4E-L-DC100V-D Datasheet
HC4E-L-DC100V-D
Current Part
MY4N-D2 DC100/110 (S)
Omron Automation and SafetyIn Stock: 876MY4N-D2 DC100/110 (S) Datasheet
MY4N-D2 DC100/110 (S)
Similar

Key Parameters

Parameter HC4E-L-DC100V-D
Manufacturer Panasonic Electric Works
Series HC4E
Contact Form 4PDT (4 Form C)
Coil Voltage 100VDC
Contact Rating (Current) 2 A
Switching Voltage (Max) 250VAC
Mounting Type Socketable
Termination Style Plug In
Coil Type Non Latching
Operating Temperature Range -50°C ~ 60°C
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution of the HC4E-L-DC100V-D is determined by the following critical parameters that must align or exceed the original specification:

Mandatory Matching Parameters:

  • Contact form: 4PDT (4 Form C) configuration
  • Mounting type: Socketable with plug-in termination
  • Coil type: Non-latching operation
  • Coil voltage: 100VDC nominal (acceptable range: 88VDC to 110VDC based on must-operate and must-release specifications)

Acceptable Upgrade Parameters:

  • Contact rating (current): Equal to or greater than 2A
  • Switching voltage: Equal to or greater than 250VAC
  • Operating temperature range: Equal to or wider than -50°C ~ 60°C
  • Coil current: Lower values acceptable (reduced power consumption)

The MY4N-D2 DC100/110 (S) from Omron Automation and Safety qualifies as a substitute based on these criteria.

Parameter Comparison

Parameter HC4E-L-DC100V-D (Main) MY4N-D2 DC100/110 (S) (Substitute) Compatibility Status
Contact Form 4PDT (4 Form C) 4PDT (4 Form C) Match
Coil Voltage 100VDC 110VDC Compatible (within operating range)
Contact Rating (Current) 2 A 3 A Upgrade (exceeds requirement)
Switching Voltage (Max) 250VAC 250VAC, 125VDC Match/Upgrade
Mounting Type Socketable Socketable Match
Termination Style Plug In Plug In Match
Coil Type Non Latching Non Latching Match
Coil Current 11 mA 9 mA Improvement (lower consumption)
Must Operate Voltage 80 VDC 88 VDC Compatible
Must Release Voltage 10 VDC 11 VDC Compatible
Operate Time 20 ms 20 ms Match
Release Time 20 ms 20 ms Match
Operating Temperature Range -50°C ~ 60°C -55°C ~ 70°C Upgrade (wider range)
Contact Material Silver Alloy, Cadmium Free Silver (Ag) Compatible
Product Status Obsolete Active Active sourcing available

Engineering Selection Recommendations

The MY4N-D2 DC100/110 (S) is a direct substitute for the HC4E-L-DC100V-D based on functional equivalence across all critical parameters. The substitute part is currently active in production, ensuring long-term availability and supply chain continuity compared to the obsolete original component.

The MY4N-D2 DC100/110 (S) provides performance improvements including higher contact current rating (3A vs. 2A), lower coil current consumption (9mA vs. 11mA), and an extended operating temperature range (-55°C ~ 70°C vs. -50°C ~ 60°C). The substitute is RoHS compliant, meeting modern regulatory requirements for electronic components.

Both relays maintain identical switching characteristics (20ms operate and release times) and contact form configuration, ensuring functional compatibility in existing circuit designs. The socketable mounting and plug-in termination style are identical, allowing direct mechanical and electrical replacement without circuit board modifications.

Frequently Asked Questions (FAQ)

Q: Can the MY4N-D2 DC100/110 (S) be used as a direct replacement for the HC4E-L-DC100V-D?

A: Yes. Both relays share identical contact form (4PDT), mounting type (socketable), termination style (plug-in), and switching timing (20ms). The substitute meets or exceeds all electrical specifications of the original component.

Q: What is the voltage compatibility between 100VDC and 110VDC coil specifications?

A: The MY4N-D2 DC100/110 (S) with 110VDC coil will operate reliably in circuits designed for 100VDC. The must-operate voltage of 88VDC and must-release voltage of 11VDC for the substitute encompass the original part's operating envelope (80VDC to 10VDC), ensuring functional compatibility across the specified voltage range.

Q: Does the higher contact current rating (3A vs. 2A) affect circuit compatibility?

A: No. A higher contact current rating indicates the substitute can safely handle greater switching loads. In applications where the original 2A rating was sufficient, the 3A-rated substitute will perform identically without adverse effects.

Q: Are there packaging or inventory considerations for this substitution?

A: The MY4N-D2 DC100/110 (S) is available in bulk packaging with active production status, providing reliable sourcing. The HC4E-L-DC100V-D is obsolete. For new designs or system repairs, the Omron substitute ensures component availability and supply chain stability.

Q: What are the compliance differences between these relays?

A: The MY4N-D2 DC100/110 (S) is RoHS compliant, meeting current environmental and regulatory standards. The HC4E-L-DC100V-D, being obsolete, does not carry current compliance certifications. For applications requiring RoHS compliance, the substitute is the appropriate choice.

Request Quote (Ships tomorrow)