HC4ED-PL-DC100V Equivalent & Substitute Parts

Part Overview

The HC4ED-PL-DC100V is a general purpose relay manufactured by Panasonic Electric Works, featuring a 4PDT (4 Form C) contact configuration with a 100VDC coil. This through-hole mounted relay is designed for applications requiring multiple independent switching circuits with a 1A contact rating at up to 250VAC switching voltage. The product is currently obsolete, making identification of compatible substitute components essential for system maintenance, repair, and redesign applications.

Substiute Parts

HC4ED-PL-DC100V
Panasonic Electric WorksIn Stock: 806HC4ED-PL-DC100V Datasheet
HC4ED-PL-DC100V
Current Part
MY4-02-DC100/110
Omron Automation and SafetyIn Stock: 666MY4-02-DC100/110 Datasheet
MY4-02-DC100/110
Similar

Key Parameters

Parameter HC4ED-PL-DC100V
Manufacturer Panasonic Electric Works
Series HCE
Coil Voltage 100VDC
Contact Form 4PDT (4 Form C)
Contact Rating (Current) 1 A
Switching Voltage 250VAC - Max
Mounting Type Through Hole
Coil Current 11 mA
Coil Type Non Latching
Termination Style PC Pin
Operating Temperature Range -40°C ~ 60°C
Contact Material Silver Nickel (AgNi), Gold (Au)
Coil Resistance 10 kOhms
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution of the HC4ED-PL-DC100V is determined by the following critical parameters:

Contact Configuration: The 4PDT (4 Form C) contact form is mandatory for functional equivalence, as it provides four independent switching circuits required by the original design.

Coil Voltage Class: The 100VDC coil voltage establishes the control signal requirement. Substitutes within the 100-110VDC range are acceptable based on standard industrial relay voltage tolerance specifications.

Contact Rating: The 1A contact current rating defines the maximum load-switching capability. Substitutes with equal or higher current ratings (3A or greater) maintain backward compatibility.

Switching Voltage: The 250VAC maximum switching voltage specification must be met or exceeded by substitute components.

Mounting and Termination: Through-hole mounting with PC pin termination is required for direct board-level compatibility.

Coil Type: Non-latching operation is essential for applications requiring continuous coil energization to maintain contact closure.

The MY4-02-DC100/110 from Omron Automation and Safety meets all substitution criteria within these parameters.

Parameter Comparison

Parameter HC4ED-PL-DC100V (Panasonic) MY4-02-DC100/110 (Omron)
Coil Voltage 100VDC 110VDC
Contact Form 4PDT (4 Form C) 4PDT (4 Form C)
Contact Rating (Current) 1 A 3 A
Switching Voltage 250VAC - Max 250VAC, 125VDC - Max
Mounting Type Through Hole Through Hole
Coil Current 11 mA 9.1 mA
Coil Type Non Latching Non Latching
Termination Style PC Pin PC Pin
Operating Temperature Range -40°C ~ 60°C -55°C ~ 70°C
Coil Resistance 10 kOhms 11 kOhms
Must Operate Voltage 80 VDC 88 VDC
Must Release Voltage 10 VDC 11 VDC
Operate Time 20 ms 20 ms
Release Time 20 ms 20 ms
Product Status Obsolete Active

Engineering Selection Recommendations

The MY4-02-DC100/110 is the qualified substitute for the HC4ED-PL-DC100V based on the following engineering criteria:

Functional Compatibility: Both relays provide identical 4PDT contact configuration and non-latching coil operation, ensuring direct functional replacement in existing circuit designs.

Coil Voltage Alignment: The 110VDC coil voltage of the MY4-02-DC100/110 is within standard industrial tolerance of the original 100VDC specification, with must-operate and must-release voltages (88VDC and 11VDC respectively) compatible with typical control circuit designs.

Enhanced Contact Rating: The MY4-02-DC100/110 provides 3A contact rating compared to the original 1A rating, offering improved margin for load-switching applications without requiring circuit redesign.

Active Product Status: The MY4-02-DC100/110 is currently in active production, ensuring long-term availability and supply chain continuity for new designs and ongoing maintenance requirements.

Compliance and Certification: Both components share identical ECCN (EAR99) and HTSUS (8536.49.0050) classifications. The MY4-02-DC100/110 carries RoHS compliance certification, meeting modern regulatory requirements.

Thermal Performance: The MY4-02-DC100/110 extends the operating temperature range to -55°C ~ 70°C, providing broader environmental compatibility compared to the original -40°C ~ 60°C range.

Frequently Asked Questions (FAQ)

Q: Can the MY4-02-DC100/110 directly replace the HC4ED-PL-DC100V without circuit modification?

A: Yes. Both relays share identical 4PDT contact configuration, PC pin termination, through-hole mounting, and 20ms operate/release timing. The 110VDC coil voltage is within standard industrial tolerance of the 100VDC original specification.

Q: What is the significance of the higher 3A contact rating on the MY4-02-DC100/110?

A: The MY4-02-DC100/110 provides 3A contact rating versus the original 1A rating. This represents increased load-switching capacity and is backward compatible with applications originally designed for 1A operation. No circuit modification is required.

Q: Are there packaging differences between these relays?

A: The HC4ED-PL-DC100V uses standard through-hole PC pin termination. The MY4-02-DC100/110 is supplied in bulk packaging and maintains identical through-hole PC pin termination, ensuring mechanical and electrical compatibility on printed circuit boards.

Q: How do the coil current specifications compare?

A: The MY4-02-DC100/110 draws 9.1mA compared to the original 11mA. This lower coil current reduces control circuit power consumption while maintaining identical switching performance and timing characteristics.

Q: What compliance advantages does the MY4-02-DC100/110 offer?

A: The MY4-02-DC100/110 is RoHS compliant and carries active product status, ensuring compliance with modern environmental regulations and long-term component availability for new system designs and maintenance applications.

Request Quote (Ships tomorrow)