The HC4D-HTM-AC24V is a general purpose relay manufactured by Panasonic Electric Works, featuring a 4PDT (4 Form C) contact configuration with a 24VAC coil and 3A contact rating. This relay is designed for chassis mount applications with plug-in, 14-pin termination. The product is currently obsolete, making equivalent substitute parts necessary for ongoing maintenance, repair, and new design implementations where this relay specification remains applicable.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Coil Voltage | 24VAC |
| Contact Form | 4PDT (4 Form C) |
| Contact Rating (Current) | 3 A |
| Switching Voltage | 250VAC - Max |
| Mounting Type | Chassis Mount |
| Coil Type | Non Latching |
| Must Operate Voltage | 19.2 VAC |
| Must Release Voltage | 7.2 VAC |
| Operate Time | 20 ms |
| Release Time | 20 ms |
| Operating Temperature Range | -50°C ~ 70°C |
Substitute Part Grouping Explanation
Substitute parts for the HC4D-HTM-AC24V are identified based on the following critical parameters that determine functional equivalence:
- Coil voltage: 24VAC
- Contact configuration: 4PDT (4 Form C)
- Contact current rating: 3 A minimum
- Coil type: Non Latching
- Must operate and release voltage thresholds: 19.2 VAC and 7.2 VAC respectively
- Switching voltage capability: 250VAC minimum
- Operating temperature range compatibility
The MY4F AC24 from Omron Automation and Safety meets all these core substitution criteria, providing functional equivalence for applications requiring the HC4D-HTM-AC24V specification.
Parameter Comparison
| Parameter | HC4D-HTM-AC24V (Panasonic) | MY4F AC24 (Omron) |
|---|---|---|
| Manufacturer | Panasonic Electric Works | Omron Automation and Safety |
| Coil Voltage | 24VAC | 24VAC |
| Contact Form | 4PDT (4 Form C) | 4PDT (4 Form C) |
| Contact Rating (Current) | 3 A | 3 A |
| Switching Voltage - Max | 250VAC | 250VAC, 125VDC |
| Coil Current | 50 mA | 46 mA |
| Coil Type | Non Latching | Non Latching |
| Must Operate Voltage | 19.2 VAC | 19.2 VAC |
| Must Release Voltage | 7.2 VAC | 7.2 VAC |
| Operate Time | 20 ms | 20 ms |
| Release Time | 20 ms | 20 ms |
| Operating Temperature Range | -50°C ~ 70°C | -55°C ~ 70°C |
| Product Status | Obsolete | Active |
| Mounting Type | Chassis Mount | Chassis Mount |
| Termination Style | Plug In, 14 Pin | Solder Lug |
| Contact Material | Silver Nickel (AgNi), Gold (Au) | Silver (Ag) |
| Coil Resistance | 480 Ohms | 180 Ohms |
| RoHS Status | Not specified | RoHS Compliant |
| REACH Status | Not specified | REACH Unaffected |
Engineering Selection Recommendations
The MY4F AC24 is the active substitute for the obsolete HC4D-HTM-AC24V. Both relays share identical electrical specifications for coil voltage, contact configuration, current rating, and switching characteristics. The MY4F AC24 offers the advantage of active product status with RoHS compliance and REACH unaffected certification, ensuring long-term availability and regulatory alignment.
The primary consideration for substitution is the termination style difference: the HC4D-HTM-AC24V uses plug-in, 14-pin termination, while the MY4F AC24 uses solder lug termination. This requires mechanical adaptation in the application circuit or PCB design. The MY4F AC24 also provides extended operating temperature range (-55°C versus -50°C minimum) and dual voltage switching capability (250VAC and 125VDC), offering enhanced flexibility for various application environments.
Frequently Asked Questions (FAQ)
Q: Can the MY4F AC24 directly replace the HC4D-HTM-AC24V without modification?
A: Electrical substitution is valid. However, termination style differs: the HC4D-HTM-AC24V uses plug-in, 14-pin connectors while the MY4F AC24 uses solder lugs. Mechanical adaptation of the mounting interface is required.
Q: Are the coil resistance values different between these relays?
A: Yes. The HC4D-HTM-AC24V has 480 Ohms coil resistance while the MY4F AC24 has 180 Ohms. Both achieve the same 24VAC coil voltage specification with coil currents of 50 mA and 46 mA respectively, maintaining functional equivalence in 24VAC circuits.
Q: What is the impact of the extended operating temperature range in the MY4F AC24?
A: The MY4F AC24 operates from -55°C to 70°C compared to the HC4D-HTM-AC24V range of -50°C to 70°C. This provides additional margin for low-temperature applications, though both relays cover standard industrial temperature ranges.
Q: Does the MY4F AC24 support both AC and DC switching?
A: The MY4F AC24 switching voltage rating is 250VAC and 125VDC maximum, providing dual-voltage capability. The HC4D-HTM-AC24V is rated for 250VAC maximum. Both are suitable for AC applications; the MY4F AC24 offers additional DC switching capability.
Q: Is RoHS compliance a factor in selecting the MY4F AC24?
A: The MY4F AC24 is RoHS compliant with REACH unaffected status. The HC4D-HTM-AC24V compliance status is not specified. For applications requiring regulatory compliance documentation, the MY4F AC24 provides certified compliance.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts