HC2-H-DC12V-F Equivalent & Substitute Parts

Part Overview

The HC2-H-DC12V-F is a general purpose relay manufactured by Panasonic Electric Works, featuring a DPDT (2 Form C) contact configuration with a 12VDC coil and 7A contact rating. This socketable relay is designed for standard switching applications requiring reliable electromagnetic actuation. The product is currently obsolete, making equivalent and substitute parts necessary for system maintenance, repair, and new design implementations where compatible alternatives are required.

Substiute Parts

HC2-H-DC12V-F
Panasonic Electric WorksIn Stock: 693HC2-H-DC12V-F Datasheet
HC2-H-DC12V-F
Current Part
MY2 DC12 (S)
Omron Automation and SafetyIn Stock: 2494MY2 DC12 (S) Datasheet
MY2 DC12 (S)
Direct
KHAU-11D12-12
TE Connectivity Potter & Brumfield RelaysIn Stock: 3229KHAU-11D12-12 Datasheet
KHAU-11D12-12
Similar
LY2-DC12
Omron Automation and SafetyIn Stock: 10362LY2-DC12 Datasheet
LY2-DC12
Similar

Key Parameters

Parameter Value
Coil Voltage 12VDC
Contact Form DPDT (2 Form C)
Contact Rating (Current) 7 A
Mounting Type Socketable
Termination Style Plug In
Coil Current 75 mA
Coil Resistance 160 Ohms
Must Operate Voltage 9.6 VDC
Must Release Voltage 1.2 VDC
Switching Voltage (Max) 250VAC
Operating Temperature Range -50°C ~ 70°C
Coil Type Non Latching

Substitute Part Grouping Explanation

Substitution of the HC2-H-DC12V-F is determined by strict alignment of the following critical parameters:

Essential Matching Parameters:

  • Coil voltage: 12VDC (all substitutes must operate at this voltage)
  • Contact form: DPDT (2 Form C) configuration (electrical switching topology requirement)
  • Mounting type: Socketable (physical form factor and base compatibility)
  • Termination style: Plug In (connector interface requirement)
  • Coil current: 75 mA (drive circuit compatibility)
  • Coil resistance: 160 Ohms (electrical load matching)
  • Must operate voltage: 9.6 VDC (minimum activation threshold)
  • Must release voltage: 1.2 VDC (deactivation threshold)
  • Coil type: Non Latching (functional behavior requirement)

Allowable Variation Parameters:

  • Contact rating (current): Substitutes with equal or higher current rating are acceptable (7A minimum)
  • Switching voltage: Substitutes must support minimum 250VAC
  • Operating temperature range: Substitutes must cover the application temperature envelope
  • Contact material: Variations permitted if electrical performance is maintained
  • Operate/Release time: Variations permitted within application timing requirements

The three substitute parts listed below meet all essential matching parameters while maintaining functional equivalence for the HC2-H-DC12V-F application.

Parameter Comparison

Parameter HC2-H-DC12V-F (Main) MY2 DC12 (S) KHAU-11D12-12 LY2-DC12
Manufacturer Panasonic Electric Works Omron Automation and Safety TE Connectivity Potter & Brumfield Relays Omron Automation and Safety
Product Status Obsolete Active Active Active
Coil Voltage 12VDC 12VDC 12VDC 12VDC
Contact Form DPDT (2 Form C) DPDT (2 Form C) DPDT (2 Form C) DPDT (2 Form C)
Contact Rating (Current) 7 A 5 A 5 A 10 A
Mounting Type Socketable Socketable Socketable Socketable
Termination Style Plug In Plug In Plug In Plug In
Coil Current 75 mA 75 mA 75 mA 75 mA
Coil Resistance 160 Ohms 160 Ohms 160 Ohms 160 Ohms
Must Operate Voltage 9.6 VDC 9.6 VDC 9 VDC 9.6 VDC
Must Release Voltage 1.2 VDC 1.2 VDC Not specified 1.2 VDC
Switching Voltage (Max) 250VAC 250VAC, 125VDC 240VAC 250VAC, 125VDC
Operate Time 20 ms 20 ms 13 ms 25 ms
Release Time 20 ms 20 ms 6 ms 25 ms
Operating Temperature Range -50°C ~ 70°C -55°C ~ 70°C -45°C ~ 70°C -25°C ~ 55°C
Contact Material Silver Alloy, Cadmium Free Silver (Ag) Silver Cadmium Oxide (AgCdO) Silver Alloy
Coil Type Non Latching Non Latching Non Latching Non Latching
RoHS Status Not specified RoHS Compliant RoHS non-compliant ROHS3 Compliant
REACH Status Not specified REACH Unaffected REACH Affected REACH Unaffected

Engineering Selection Recommendations

MY2 DC12 (S) - Omron Automation and Safety

This substitute provides direct functional equivalence with identical coil voltage, contact form, mounting type, and coil parameters. The contact rating of 5A is lower than the original 7A specification; this substitute is suitable for applications where the load current does not exceed 5A. The part is active in production with RoHS and REACH compliance, ensuring long-term availability and regulatory alignment. Operating temperature range extends to -55°C, providing superior low-temperature performance compared to the original specification.

KHAU-11D12-12 - TE Connectivity Potter & Brumfield Relays

This substitute meets all essential electrical parameters with identical coil voltage, contact form, and mounting configuration. The contact rating of 5A requires load current verification. The must operate voltage of 9VDC is lower than the original 9.6VDC specification, providing improved activation margin. Operate and release times are faster (13ms and 6ms respectively) compared to the original 20ms specification. The part is RoHS non-compliant and REACH affected; regulatory compliance must be evaluated for the target application. Operating temperature range of -45°C ~ 70°C covers the original specification envelope.

LY2-DC12 - Omron Automation and Safety

This substitute provides the highest contact rating at 10A, exceeding the original 7A specification and offering increased current capacity for higher-load applications. All essential electrical parameters match the original specification. The part is active in production with ROHS3 and REACH compliance. Operating temperature range of -25°C ~ 55°C is narrower than the original specification; this substitute is not suitable for applications requiring operation below -25°C. Operate and release times are slightly longer at 25ms compared to the original 20ms specification.

Frequently Asked Questions (FAQ)

Q: Can MY2 DC12 (S) replace HC2-H-DC12V-F in all applications?

A: MY2 DC12 (S) is functionally equivalent for applications where the load current does not exceed 5A. If the original application requires the full 7A contact rating, this substitute is not suitable. Verify the actual load current in your circuit before selection.

Q: What is the difference between the three substitute options?

A: The three substitutes differ primarily in contact rating and operating temperature range. MY2 DC12 (S) and KHAU-11D12-12 both provide 5A contact rating. LY2-DC12 provides 10A contact rating but has a narrower operating temperature range (-25°C ~ 55°C). Select based on your application's current requirements and temperature envelope.

Q: Is KHAU-11D12-12 suitable for new designs?

A: KHAU-11D12-12 is RoHS non-compliant and REACH affected. For new designs subject to RoHS or REACH regulations, this part is not recommended. MY2 DC12 (S) and LY2-DC12 are both RoHS compliant and REACH unaffected, making them preferable for regulated applications.

Q: Can I use LY2-DC12 in applications requiring operation below -25°C?

A: No. LY2-DC12 has an operating temperature range of -25°C ~ 55°C. The original HC2-H-DC12V-F specification extends to -50°C. For low-temperature applications, MY2 DC12 (S) (-55°C ~ 70°C) or KHAU-11D12-12 (-45°C ~ 70°C) are suitable alternatives.

Q: Are all substitutes socketable with plug-in termination?

A: Yes. All three substitute parts are socketable relays with plug-in termination, matching the original HC2-H-DC12V-F form factor and base compatibility.

Q: What is the coil current requirement for all these relays?

A: All four relays (original and three substitutes) require 75mA coil current with 160 Ohms coil resistance. Drive circuit compatibility is maintained across all options.

Q: Do the substitutes have the same switching voltage capability?

A: The original HC2-H-DC12V-F supports 250VAC maximum. MY2 DC12 (S) and LY2-DC12 support 250VAC and 125VDC. KHAU-11D12-12 supports 240VAC maximum. All meet or exceed the original 250VAC specification for AC switching applications.

Request Quote (Ships tomorrow)