Part Overview
The HC1-H-AC100V-F is a general purpose relay manufactured by Panasonic Electric Works, featuring SPDT (1 Form C) contact configuration with 10A contact rating and 100VAC coil voltage. This socketable relay is designed for general-purpose switching applications requiring reliable electromagnetic actuation. The product is currently obsolete, making identification of compatible substitute parts essential for system maintenance, repair, and redesign applications where continued availability is required.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | HC1-H-AC100V-F |
| Manufacturer | Panasonic Electric Works |
| Series | HC |
| Product Status | Obsolete |
| Relay Type | General Purpose |
| Contact Form | SPDT (1 Form C) |
| Contact Rating (Current) | 10 A |
| Coil Voltage | 100VAC |
| Switching Voltage (Max) | 250VAC |
| Mounting Type | Socketable |
| Termination Style | Plug In |
| Operating Temperature Range | -50°C ~ 70°C |
| Contact Material | Silver Alloy, Cadmium Free |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitution of the HC1-H-AC100V-F is determined by the following critical parameters that must align between the main part and substitute candidates:
Primary Substitution Criteria:
- Contact Form: SPDT (1 Form C) configuration
- Contact Rating: 10 A minimum
- Coil Voltage: 100VAC nominal (acceptable range: 88VAC to 110VAC based on must-operate and must-release specifications)
- Mounting Type: Socketable with plug-in termination
- Relay Type: General Purpose
- Switching Voltage: Minimum 250VAC capability
The G2R-1-S AC110(S) manufactured by Omron Automation and Safety meets these substitution criteria. While the coil voltage is specified as 110VAC rather than 100VAC, the must-operate voltage of 88VAC and must-release voltage of 33VAC establish compatibility within standard AC supply tolerance ranges. Both relays maintain identical contact form, current rating, socketable mounting, and plug-in termination, enabling direct functional substitution in applications designed for the HC1-H-AC100V-F.
Parameter Comparison
| Parameter | HC1-H-AC100V-F (Panasonic) | G2R-1-S AC110(S) (Omron) |
|---|---|---|
| Contact Form | SPDT (1 Form C) | SPDT (1 Form C) |
| Contact Rating (Current) | 10 A | 10 A |
| Coil Voltage | 100VAC | 110VAC |
| Switching Voltage (Max) | 250VAC | 440VAC, 125VDC |
| Coil Current | 13.2 mA | 8.2 mA |
| Must Operate Voltage | 80 VAC | 88 VAC |
| Must Release Voltage | 30 VAC | 33 VAC |
| Operate Time | 20 ms | 15 ms |
| Release Time | 20 ms | 10 ms |
| Operating Temperature Range | -50°C ~ 70°C | -40°C ~ 70°C |
| Mounting Type | Socketable | Socketable |
| Termination Style | Plug In | Plug In, Quick Connect - 0.187" (4.7mm) |
| Relay Type | General Purpose | General Purpose |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) |
| ECCN | EAR99 | EAR99 |
Engineering Selection Recommendations
The G2R-1-S AC110(S) is the identified substitute for the obsolete HC1-H-AC100V-F. Selection of this substitute is supported by the following factors:
Product Status: The G2R-1-S AC110(S) maintains Active product status, ensuring continued availability and supply chain reliability compared to the obsolete HC1-H-AC100V-F.
Compliance & Certifications: Both relays carry identical ECCN classification (EAR99) and MSL rating (1 - Unlimited). The G2R-1-S AC110(S) additionally carries RoHS3 Compliance and REACH Unaffected status, meeting modern regulatory requirements.
Functional Compatibility: Identical contact form (SPDT), current rating (10A), and socketable mounting with plug-in termination ensure mechanical and electrical interchangeability. The coil voltage differential (100VAC vs. 110VAC) falls within acceptable AC supply tolerance ranges, with must-operate and must-release voltage specifications confirming reliable actuation in standard 100-110VAC supply environments.
Performance Characteristics: The G2R-1-S AC110(S) demonstrates improved switching voltage capability (440VAC, 125VDC vs. 250VAC), reduced coil current draw (8.2mA vs. 13.2mA), and faster response times (15ms operate, 10ms release vs. 20ms each), providing performance advantages in the substitution.
Frequently Asked Questions (FAQ)
Q: Can the G2R-1-S AC110(S) directly replace the HC1-H-AC100V-F in existing applications?
A: Yes. Both relays share identical SPDT contact form, 10A current rating, socketable mounting, and plug-in termination. The 110VAC coil voltage of the substitute operates within the acceptable range defined by the 88VAC must-operate specification, ensuring reliable actuation in standard 100-110VAC supply environments.
Q: What is the significance of the coil voltage difference (100VAC vs. 110VAC)?
A: The 10VAC difference represents standard AC supply tolerance. The G2R-1-S AC110(S) must-operate voltage of 88VAC and must-release voltage of 33VAC confirm the relay will function reliably across typical AC supply variations. This is a normal substitution parameter within industrial relay applications.
Q: Are there any temperature range limitations when substituting?
A: The G2R-1-S AC110(S) operates across -40°C to 70°C, compared to the HC1-H-AC100V-F range of -50°C to 70°C. Applications requiring operation below -40°C may require additional evaluation. For standard industrial environments, this difference is not typically limiting.
Q: What packaging considerations apply to this substitution?
A: The HC1-H-AC100V-F is specified with socketable mounting and plug-in termination. The G2R-1-S AC110(S) maintains identical socketable mounting and plug-in termination with Quick Connect - 0.187" (4.7mm) capability, ensuring compatibility with existing relay sockets and wiring harnesses.
Q: Does the substitute offer any performance improvements?
A: The G2R-1-S AC110(S) provides higher maximum switching voltage (440VAC, 125VDC vs. 250VAC), lower coil current consumption (8.2mA vs. 13.2mA), and faster response times (15ms operate, 10ms release vs. 20ms each). These characteristics represent performance enhancements suitable for modern applications.
Q: What compliance advantages does the substitute provide?
A: The G2R-1-S AC110(S) carries RoHS3 Compliance and REACH Unaffected status, meeting current environmental and regulatory requirements. Both relays maintain EAR99 export classification and MSL 1 (Unlimited) moisture sensitivity rating.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts