Request Quote
(Ships tomorrow)
HASS 500-S Hall Effect Current Sensor Equivalent & Substitute Parts
Part Overview
The HASS 500-S is a Hall Effect open loop bidirectional current sensor manufactured by LEM USA Inc., designed for AC/DC current measurement applications up to 500A. This component features ratiometric voltage output, operates across DC to 50kHz frequency range, and is housed in a through-hole module package.
The HASS 500-S carries a "Not For New Designs" product status designation. This status necessitates identification of equivalent substitute parts for ongoing production requirements, maintenance applications, and design continuity where this sensor remains functionally appropriate.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | HASS 500-S |
| Manufacturer | LEM USA Inc. |
| Series | HASS |
| Sensor Type | Hall Effect, Open Loop |
| Current Sensing Range | 500A |
| Number of Channels | 1 |
| Output Type | Ratiometric, Voltage |
| Frequency Range | DC ~ 50kHz |
| Linearity | ±0.5% |
| Accuracy | ±1% |
| Supply Voltage | 5V |
| Response Time | 3µs |
| Maximum Supply Current | 19mA |
| Operating Temperature Range | -40°C ~ 85°C |
| Polarization | Bidirectional |
| Mounting Type | Through Hole |
| Package Type | Module |
| Packaging Format | Tray |
| RoHS Status | RoHS Compliant |
| REACH Status | REACH Unaffected |
Substitute Part Grouping Explanation
Substitute parts within the HASS series are determined by the following critical parameters that must remain constant across all equivalent options:
Fixed Parameters (Non-Negotiable for Substitution):
- Sensor Type: Hall Effect, Open Loop
- Output Type: Ratiometric, Voltage
- Number of Channels: 1
- Frequency Range: DC ~ 50kHz
- Linearity: ±0.5%
- Accuracy: ±1%
- Supply Voltage: 5V
- Response Time: 3µs
- Maximum Supply Current: 19mA
- Operating Temperature Range: -40°C ~ 85°C
- Polarization: Bidirectional
- Mounting Type: Through Hole
- Package Type: Module
- Compliance: RoHS Compliant, REACH Unaffected
Variable Parameter (Determines Substitution Applicability):
- Current Sensing Range: 50A, 200A, 300A, 400A, 500A
The HASS 500-S can be substituted with HASS 200-S, HASS 300-S, HASS 400-S, or HASS 50-S based on application current requirements. Selection depends on the maximum current that must be measured in the target application.
Parameter Comparison
| Parameter | HASS 500-S | HASS 400-S | HASS 300-S | HASS 200-S | HASS 50-S |
|---|---|---|---|---|---|
| Current Sensing Range | 500A | 400A | 300A | 200A | 50A |
| Sensor Type | Hall Effect, Open Loop | Hall Effect, Open Loop | Hall Effect, Open Loop | Hall Effect, Open Loop | Hall Effect, Open Loop |
| Output Type | Ratiometric, Voltage | Ratiometric, Voltage | Ratiometric, Voltage | Ratiometric, Voltage | Ratiometric, Voltage |
| Number of Channels | 1 | 1 | 1 | 1 | 1 |
| Frequency Range | DC ~ 50kHz | DC ~ 50kHz | DC ~ 50kHz | DC ~ 50kHz | DC ~ 50kHz |
| Linearity | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Accuracy | ±1% | ±1% | ±1% | ±1% | ±1% |
| Supply Voltage | 5V | 5V | 5V | 5V | 5V |
| Response Time | 3µs | 3µs | 3µs | 3µs | 3µs |
| Maximum Supply Current | 19mA | 19mA | 19mA | 19mA | 19mA |
| Operating Temperature Range | -40°C ~ 85°C | -40°C ~ 85°C | -40°C ~ 85°C | -40°C ~ 85°C | -40°C ~ 85°C |
| Polarization | Bidirectional | Bidirectional | Bidirectional | Bidirectional | Bidirectional |
| Mounting Type | Through Hole | Through Hole | Through Hole | Through Hole | Through Hole |
| Package Type | Module | Module | Module | Module | Module |
| RoHS Status | RoHS Compliant | RoHS Compliant | RoHS Compliant | RoHS Compliant | RoHS Compliant |
| REACH Status | REACH Unaffected | REACH Unaffected | REACH Unaffected | REACH Unaffected | REACH Unaffected |
Engineering Selection Recommendations
All parts within the HASS series substitute group maintain identical electrical characteristics, frequency response, accuracy specifications, and compliance certifications. Selection among HASS 50-S, HASS 200-S, HASS 300-S, HASS 400-S, and HASS 500-S is determined exclusively by the maximum current measurement requirement of the application.
Selection Criteria:
- HASS 50-S: Applications requiring current measurement up to 50A
- HASS 200-S: Applications requiring current measurement up to 200A
- HASS 300-S: Applications requiring current measurement up to 300A
- HASS 400-S: Applications requiring current measurement up to 400A
- HASS 500-S: Applications requiring current measurement up to 500A
All substitute parts carry identical "Not For New Designs" product status. All parts are RoHS Compliant and REACH Unaffected, meeting current regulatory requirements for electronic component manufacturing and use.
Frequently Asked Questions (FAQ)
Q: Can HASS 200-S be used as a substitute for HASS 500-S?
A: HASS 200-S is electrically and mechanically compatible with HASS 500-S only if the application maximum current requirement does not exceed 200A. The 200A current sensing range of HASS 200-S is the only parameter that differs from HASS 500-S. All other electrical specifications, output characteristics, frequency response, accuracy, and physical mounting are identical.
Q: What is the primary difference between HASS 500-S and other parts in the substitute group?
A: The current sensing range is the only parameter that varies. HASS 500-S measures currents up to 500A, while HASS 400-S measures up to 400A, HASS 300-S up to 300A, HASS 200-S up to 200A, and HASS 50-S up to 50A. All other specifications remain constant across the series.
Q: Are all HASS series parts pin-compatible?
A: Yes. All HASS series parts use identical through-hole module packaging and maintain the same physical form factor, mounting configuration, and electrical interface specifications.
Q: Can a lower-rated sensor be used in place of HASS 500-S?
A: A lower-rated sensor may be used only if the application's maximum current requirement is within the lower sensor's rating. Using a sensor with insufficient current range will result in output saturation and measurement error.
Q: Can a higher-rated sensor be used in place of HASS 500-S?
A: Higher-rated sensors are not available within the provided substitute group. The HASS 500-S represents the maximum current sensing capability within this series.
Q: Do all HASS series parts require identical supply voltage?
A: Yes. All parts in the HASS series require 5V supply voltage and draw a maximum of 19mA supply current.
Q: What is the frequency response limitation for all HASS series sensors?
A: All HASS series sensors operate across DC to 50kHz frequency range with 3µs response time, providing identical dynamic performance characteristics across the entire substitute group.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts