The HASS 500-S is a Hall Effect open loop bidirectional current sensor manufactured by LEM USA Inc., designed for AC/DC current measurement applications up to 500A. This component features ratiometric voltage output, operates across DC to 50kHz frequency range, and is housed in a through-hole module package.

The HASS 500-S carries a "Not For New Designs" product status designation. This status necessitates identification of equivalent substitute parts for ongoing production requirements, maintenance applications, and design continuity where this sensor remains functionally appropriate.

Substiute Parts

HASS 500-S
LEM USA Inc.In Stock: 1379HASS 500-S Datasheet
HASS 500-S
Current Part
HASS 200-S
LEM USA Inc.In Stock: 9118HASS 200-S Datasheet
HASS 200-S
Parametric Equivalent
HASS 300-S
LEM USA Inc.In Stock: 6792HASS 300-S Datasheet
HASS 300-S
Parametric Equivalent
HASS 400-S
LEM USA Inc.In Stock: 4268HASS 400-S Datasheet
HASS 400-S
Parametric Equivalent
HASS 50-S
LEM USA Inc.In Stock: 8258HASS 50-S Datasheet
HASS 50-S
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Part Number HASS 500-S
Manufacturer LEM USA Inc.
Series HASS
Sensor Type Hall Effect, Open Loop
Current Sensing Range 500A
Number of Channels 1
Output Type Ratiometric, Voltage
Frequency Range DC ~ 50kHz
Linearity ±0.5%
Accuracy ±1%
Supply Voltage 5V
Response Time 3µs
Maximum Supply Current 19mA
Operating Temperature Range -40°C ~ 85°C
Polarization Bidirectional
Mounting Type Through Hole
Package Type Module
Packaging Format Tray
RoHS Status RoHS Compliant
REACH Status REACH Unaffected

Substitute Part Grouping Explanation

Substitute parts within the HASS series are determined by the following critical parameters that must remain constant across all equivalent options:

Fixed Parameters (Non-Negotiable for Substitution):

  • Sensor Type: Hall Effect, Open Loop
  • Output Type: Ratiometric, Voltage
  • Number of Channels: 1
  • Frequency Range: DC ~ 50kHz
  • Linearity: ±0.5%
  • Accuracy: ±1%
  • Supply Voltage: 5V
  • Response Time: 3µs
  • Maximum Supply Current: 19mA
  • Operating Temperature Range: -40°C ~ 85°C
  • Polarization: Bidirectional
  • Mounting Type: Through Hole
  • Package Type: Module
  • Compliance: RoHS Compliant, REACH Unaffected

Variable Parameter (Determines Substitution Applicability):

  • Current Sensing Range: 50A, 200A, 300A, 400A, 500A

The HASS 500-S can be substituted with HASS 200-S, HASS 300-S, HASS 400-S, or HASS 50-S based on application current requirements. Selection depends on the maximum current that must be measured in the target application.

Parameter Comparison

Parameter HASS 500-S HASS 400-S HASS 300-S HASS 200-S HASS 50-S
Current Sensing Range 500A 400A 300A 200A 50A
Sensor Type Hall Effect, Open Loop Hall Effect, Open Loop Hall Effect, Open Loop Hall Effect, Open Loop Hall Effect, Open Loop
Output Type Ratiometric, Voltage Ratiometric, Voltage Ratiometric, Voltage Ratiometric, Voltage Ratiometric, Voltage
Number of Channels 1 1 1 1 1
Frequency Range DC ~ 50kHz DC ~ 50kHz DC ~ 50kHz DC ~ 50kHz DC ~ 50kHz
Linearity ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Accuracy ±1% ±1% ±1% ±1% ±1%
Supply Voltage 5V 5V 5V 5V 5V
Response Time 3µs 3µs 3µs 3µs 3µs
Maximum Supply Current 19mA 19mA 19mA 19mA 19mA
Operating Temperature Range -40°C ~ 85°C -40°C ~ 85°C -40°C ~ 85°C -40°C ~ 85°C -40°C ~ 85°C
Polarization Bidirectional Bidirectional Bidirectional Bidirectional Bidirectional
Mounting Type Through Hole Through Hole Through Hole Through Hole Through Hole
Package Type Module Module Module Module Module
RoHS Status RoHS Compliant RoHS Compliant RoHS Compliant RoHS Compliant RoHS Compliant
REACH Status REACH Unaffected REACH Unaffected REACH Unaffected REACH Unaffected REACH Unaffected

Engineering Selection Recommendations

All parts within the HASS series substitute group maintain identical electrical characteristics, frequency response, accuracy specifications, and compliance certifications. Selection among HASS 50-S, HASS 200-S, HASS 300-S, HASS 400-S, and HASS 500-S is determined exclusively by the maximum current measurement requirement of the application.

Selection Criteria:

  • HASS 50-S: Applications requiring current measurement up to 50A
  • HASS 200-S: Applications requiring current measurement up to 200A
  • HASS 300-S: Applications requiring current measurement up to 300A
  • HASS 400-S: Applications requiring current measurement up to 400A
  • HASS 500-S: Applications requiring current measurement up to 500A

All substitute parts carry identical "Not For New Designs" product status. All parts are RoHS Compliant and REACH Unaffected, meeting current regulatory requirements for electronic component manufacturing and use.

Frequently Asked Questions (FAQ)

Q: Can HASS 200-S be used as a substitute for HASS 500-S?

A: HASS 200-S is electrically and mechanically compatible with HASS 500-S only if the application maximum current requirement does not exceed 200A. The 200A current sensing range of HASS 200-S is the only parameter that differs from HASS 500-S. All other electrical specifications, output characteristics, frequency response, accuracy, and physical mounting are identical.

Q: What is the primary difference between HASS 500-S and other parts in the substitute group?

A: The current sensing range is the only parameter that varies. HASS 500-S measures currents up to 500A, while HASS 400-S measures up to 400A, HASS 300-S up to 300A, HASS 200-S up to 200A, and HASS 50-S up to 50A. All other specifications remain constant across the series.

Q: Are all HASS series parts pin-compatible?

A: Yes. All HASS series parts use identical through-hole module packaging and maintain the same physical form factor, mounting configuration, and electrical interface specifications.

Q: Can a lower-rated sensor be used in place of HASS 500-S?

A: A lower-rated sensor may be used only if the application's maximum current requirement is within the lower sensor's rating. Using a sensor with insufficient current range will result in output saturation and measurement error.

Q: Can a higher-rated sensor be used in place of HASS 500-S?

A: Higher-rated sensors are not available within the provided substitute group. The HASS 500-S represents the maximum current sensing capability within this series.

Q: Do all HASS series parts require identical supply voltage?

A: Yes. All parts in the HASS series require 5V supply voltage and draw a maximum of 19mA supply current.

Q: What is the frequency response limitation for all HASS series sensors?

A: All HASS series sensors operate across DC to 50kHz frequency range with 3µs response time, providing identical dynamic performance characteristics across the entire substitute group.