Part Overview
The HAL 600-S is an active Hall Effect current sensor manufactured by LEM USA Inc., designed for AC/DC current measurement applications requiring 600A sensing capability. This open-loop, bidirectional module delivers voltage output with ±1% accuracy and operates across industrial temperature ranges. The product maintains Active status with full RoHS compliance and REACH unaffected designation, ensuring suitability for regulated applications. Substitute parts are identified when application requirements permit reduced current-sensing capacity while maintaining identical electrical and mechanical interface characteristics.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | HAL 600-S |
| Manufacturer | LEM USA Inc. |
| Series | HAL |
| Product Status | Active |
| Sensor Type | Hall Effect, Open Loop |
| Current - Sensing | 600A |
| Number of Channels | 1 |
| Output Type | Voltage |
| Frequency Range | DC ~ 50kHz |
| Linearity | ±0.5% |
| Accuracy | ±1% |
| Voltage - Supply | ±15V |
| Response Time | 3µs |
| Current - Supply (Max) | 25mA |
| Operating Temperature | -25°C ~ 85°C |
| Polarization | Bidirectional |
| Mounting Type | Panel Mount |
| Package / Case | Module |
| RoHS Status | RoHS Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
| REACH Status | REACH Unaffected |
| ECCN | EAR99 |
| HTSUS | 9030.33.3800 |
Substitute Part Grouping Explanation
Substitution eligibility for the HAL 600-S is determined by strict equivalence across all electrical interface and mechanical parameters, with the exception of current-sensing capacity. The following parameters must remain identical across substitute parts:
Mandatory Equivalence Parameters:
- Sensor Type: Hall Effect, Open Loop
- Number of Channels: 1
- Output Type: Voltage
- Frequency Range: DC ~ 50kHz
- Linearity: ±0.5%
- Accuracy: ±1%
- Voltage - Supply: ±15V
- Response Time: 3µs
- Current - Supply (Max): 25mA
- Operating Temperature: -25°C ~ 85°C
- Polarization: Bidirectional
- Mounting Type: Panel Mount
- Package / Case: Module
- RoHS Status: RoHS Compliant
- REACH Status: REACH Unaffected
Variable Parameter (Substitution Basis):
- Current - Sensing: 600A (main part) vs. 100A (substitute)
The HAL 100-S qualifies as a parametric equivalent substitute when application current requirements do not exceed 100A. All other electrical characteristics, mechanical interfaces, and regulatory compliance remain identical.
Parameter Comparison
| Parameter | HAL 600-S | HAL 100-S | Equivalence Status |
|---|---|---|---|
| Manufacturer | LEM USA Inc. | LEM USA Inc. | Identical |
| Series | HAL | HAL | Identical |
| Sensor Type | Hall Effect, Open Loop | Hall Effect, Open Loop | Identical |
| Current - Sensing | 600A | 100A | Variable |
| Number of Channels | 1 | 1 | Identical |
| Output Type | Voltage | Voltage | Identical |
| Frequency Range | DC ~ 50kHz | DC ~ 50kHz | Identical |
| Linearity | ±0.5% | ±0.5% | Identical |
| Accuracy | ±1% | ±1% | Identical |
| Voltage - Supply | ±15V | ±15V | Identical |
| Response Time | 3µs | 3µs | Identical |
| Current - Supply (Max) | 25mA | 25mA | Identical |
| Operating Temperature | -25°C ~ 85°C | -25°C ~ 85°C | Identical |
| Polarization | Bidirectional | Bidirectional | Identical |
| Mounting Type | Panel Mount | Panel Mount | Identical |
| Package / Case | Module | Module | Identical |
| RoHS Status | RoHS Compliant | RoHS Compliant | Identical |
| REACH Status | REACH Unaffected | REACH Unaffected | Identical |
| ECCN | EAR99 | EAR99 | Identical |
| HTSUS | 9030.33.3800 | 9030.33.3800 | Identical |
Engineering Selection Recommendations
HAL 600-S Primary Selection Criteria: The HAL 600-S is the specified component for applications requiring 600A current-sensing capacity. This part maintains Active product status with full regulatory compliance (RoHS Compliant, REACH Unaffected, EAR99 classification). Current inventory of 1045 units supports immediate procurement for production deployment.
HAL 100-S Substitute Selection Criteria: The HAL 100-S functions as a direct substitute when application circuit design limits maximum current measurement to 100A or below. This part shares identical electrical interface specifications, mechanical mounting characteristics, and regulatory certifications with the HAL 600-S. The substitute maintains Active product status with significantly higher inventory availability (10,399 units), supporting extended production runs or rapid replenishment scenarios. Both parts operate within the same frequency bandwidth (DC ~ 50kHz), supply voltage range (±15V), and temperature envelope (-25°C ~ 85°C), ensuring seamless integration into existing circuit designs.
Compliance and Regulatory Alignment: Both the HAL 600-S and HAL 100-S carry identical RoHS compliance status, REACH unaffected designation, and EAR99 export classification. Selection between these parts does not introduce regulatory or compliance complications.
Frequently Asked Questions (FAQ)
Q: Under what conditions is the HAL 100-S a valid substitute for the HAL 600-S?
A: The HAL 100-S qualifies as a substitute when the application circuit design ensures that measured current does not exceed 100A. All other electrical parameters, including supply voltage (±15V), frequency response (DC ~ 50kHz), accuracy (±1%), linearity (±0.5%), response time (3µs), and operating temperature range (-25°C ~ 85°C), remain identical. The substitute maintains identical panel mount mechanical interface and module package configuration.
Q: Are there differences in output signal characteristics between the HAL 600-S and HAL 100-S?
A: Both parts deliver voltage output with identical accuracy (±1%), linearity (±0.5%), and response time (3µs). The primary difference is current-sensing range: 600A for the HAL 600-S and 100A for the HAL 100-S. Output signal conditioning, supply voltage requirements, and frequency response characteristics are identical.
Q: Can the HAL 100-S be used in a circuit designed for the HAL 600-S?
A: The HAL 100-S can be used only if the application circuit ensures that actual measured current remains below 100A. If the circuit design permits current levels exceeding 100A, the HAL 100-S will not provide accurate measurement and the HAL 600-S must be used. Mechanical mounting and electrical interface compatibility are identical.
Q: What is the inventory status for both parts?
A: The HAL 600-S maintains 1,045 units in stock. The HAL 100-S has significantly higher availability with 10,399 units in stock. Both parts are classified as New Original inventory.
Q: Are regulatory and compliance certifications identical between these parts?
A: Yes. Both the HAL 600-S and HAL 100-S carry identical RoHS Compliant status, REACH Unaffected designation, EAR99 export classification, and HTSUS code 9030.33.3800. Moisture Sensitivity Level (MSL) is 1 (Unlimited) for both parts.
Q: What is the supply voltage requirement for both sensors?
A: Both the HAL 600-S and HAL 100-S require ±15V supply voltage. Maximum supply current is 25mA for both parts.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts