GLFR2012T2R2M-LR Equivalent & Substitute Parts

Part Overview

The GLFR2012T2R2M-LR is a 2.2 µH shielded inductor manufactured by TDK Corporation, designed for surface mount applications in the 0805 (2012 Metric) package. This component is rated for 900 mA continuous current with 88 mOhm DC resistance and operates across the temperature range of -40°C to 105°C. The part is currently listed as obsolete, necessitating identification of active equivalent components to maintain design continuity and ensure supply chain availability for new production and replacement applications.

Substiute Parts

GLFR2012T2R2M-LR
TDK CorporationIn Stock: 125130GLFR2012T2R2M-LR Datasheet
GLFR2012T2R2M-LR
Current Part
MLZ2012M2R2HT000
TDK CorporationIn Stock: 25269MLZ2012M2R2HT000 Datasheet
MLZ2012M2R2HT000
MFR Recommended

Key Parameters

Parameter Value
Inductance 2.2 µH
Inductance Tolerance ±20%
Current Rating 900 mA
DC Resistance (DCR) 88 mOhm
Saturation Current (Isat) 240 mA
Package / Case 0805 (2012 Metric)
Shielding Shielded
Operating Temperature Range -40°C ~ 105°C
Mounting Type Surface Mount
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution of the GLFR2012T2R2M-LR is determined by the following critical parameters:

  • Inductance Value: 2.2 µH with ±20% tolerance
  • Package Compatibility: 0805 (2012 Metric) surface mount form factor
  • Shielding Type: Shielded construction
  • Physical Dimensions: 0.079" L x 0.049" W (2.00mm x 1.25mm)
  • Electrical Characteristics: DC resistance, current rating, and saturation current performance

The MLZ2012M2R2HT000 qualifies as a substitute based on matching inductance value, package dimensions, shielding configuration, and surface mount compatibility. While the substitute exhibits different current ratings and DC resistance specifications, these variations remain within acceptable parameters for equivalent functional performance in the 0805 shielded inductor category.

Parameter Comparison

Parameter GLFR2012T2R2M-LR MLZ2012M2R2HT000
Manufacturer TDK Corporation TDK Corporation
Inductance 2.2 µH 2.2 µH
Inductance Tolerance ±20% ±20%
Current Rating 900 mA 600 mA
DC Resistance (DCR) 88 mOhm 160 mOhm
Saturation Current (Isat) 240 mA 400 mA
Shielding Shielded Shielded
Package / Case 0805 (2012 Metric) 0805 (2012 Metric)
Size / Dimension 0.079" L x 0.049" W (2.00mm x 1.25mm) 0.079" L x 0.049" W (2.00mm x 1.25mm)
Height - Seated (Max) 0.053" (1.35mm) 0.041" (1.05mm)
Operating Temperature Range -40°C ~ 105°C -55°C ~ 125°C
Product Status Obsolete Active
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99

Engineering Selection Recommendations

The MLZ2012M2R2HT000 is the designated substitute for the obsolete GLFR2012T2R2M-LR. Selection of this alternative is supported by the following factors:

  • Product Status: The MLZ2012M2R2HT000 maintains active production status, ensuring long-term availability and supply chain continuity.
  • Regulatory Compliance: Both components share identical REACH and ECCN classifications, maintaining compliance requirements across applications.
  • Package Compatibility: Identical 0805 (2012 Metric) package dimensions enable direct PCB layout compatibility without redesign.
  • Inductance Specification: Both components deliver 2.2 µH inductance with ±20% tolerance, meeting circuit design requirements.
  • Thermal Performance: The substitute offers an extended operating temperature range (-55°C ~ 125°C) compared to the original part, providing enhanced thermal margin.

The substitute exhibits reduced current rating (600 mA versus 900 mA) and increased DC resistance (160 mOhm versus 88 mOhm). Circuit designs must evaluate whether these electrical characteristic differences are compatible with application requirements.

Frequently Asked Questions (FAQ)

Q: Can the MLZ2012M2R2HT000 be used as a direct replacement for the GLFR2012T2R2M-LR?

A: The MLZ2012M2R2HT000 is mechanically and electrically compatible for applications where the reduced current rating (600 mA) and increased DC resistance (160 mOhm) do not exceed circuit design limits. Both components share identical inductance values, package dimensions, and shielding configuration.

Q: What are the key differences between these two inductors?

A: The primary differences are current rating (900 mA versus 600 mA), DC resistance (88 mOhm versus 160 mOhm), saturation current (240 mA versus 400 mA), and product status (obsolete versus active). The substitute offers a wider operating temperature range and lower maximum seated height.

Q: Are there any PCB layout considerations when switching to the MLZ2012M2R2HT000?

A: Both components use the 0805 (2012 Metric) package with identical length and width dimensions (0.079" x 0.049"). The substitute has a lower maximum seated height (0.041" versus 0.053"), which may provide additional clearance in space-constrained designs.

Q: What compliance certifications apply to the substitute part?

A: The MLZ2012M2R2HT000 is ROHS3 compliant, REACH unaffected, and classified as EAR99 for export control purposes. Both components share identical REACH and ECCN classifications.

Q: How do the electrical characteristics affect circuit performance?

A: The increased DC resistance of the substitute (160 mOhm versus 88 mOhm) results in higher power dissipation at equivalent current levels. Applications operating near the 900 mA rating of the original part must confirm that the 600 mA rating of the substitute is sufficient for circuit requirements.

Request Quote (Ships tomorrow)