Part Overview
The G5LE-14-AP3-36 DC12 is a general purpose relay manufactured by Omron Electronics Inc-EMC Div. This SPDT (1 Form C) relay operates at 12VDC with a 10A contact rating and is designed for through-hole mounting applications. The component is currently active in production with 987 units in stock. Substitute parts are identified when equivalent electrical and mechanical parameters are maintained across the same product series, enabling flexible sourcing while preserving circuit functionality.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Coil Voltage | 12VDC |
| Contact Form | SPDT (1 Form C) |
| Contact Rating (Current) | 10 A |
| Switching Voltage | 250VAC, 125VDC - Max |
| Coil Current | 30 mA |
| Coil Resistance | 400 Ohms |
| Mounting Type | Through Hole |
| Termination Style | PC Pin |
| Operating Temperature Range | -25°C ~ 85°C |
| Contact Material | Silver Tin Oxide (AgSnO) |
| Seal Rating | Sealed - Fully |
| Coil Type | Non Latching |
Substitute Part Grouping Explanation
Substitute parts for the G5LE-14-AP3-36 DC12 are identified based on strict electrical and mechanical parameter equivalence within the G5LE series. The following parameters determine substitution eligibility:
- Coil voltage: 12VDC
- Contact form: SPDT (1 Form C)
- Contact rating: 10 A
- Switching voltage: 250VAC, 125VDC - Max
- Coil current: 30 mA
- Coil resistance: 400 Ohms
- Mounting type: Through Hole
- Termination style: PC Pin
- Operating temperature range: -25°C ~ 85°C
- Contact material: Silver Tin Oxide (AgSnO)
- Seal rating: Sealed - Fully
- Coil type: Non Latching
Variations in packaging format (tube vs. tray) do not affect electrical or mechanical compatibility and are therefore permitted within the substitution group.
Parameter Comparison
| Parameter | G5LE-14-AP3-36 DC12 | G5LE-14-36 DC12 |
|---|---|---|
| Manufacturer | Omron Electronics Inc-EMC Div | Omron Electronics Inc-EMC Div |
| Series | G5LE | G5LE |
| Coil Voltage | 12VDC | 12VDC |
| Contact Form | SPDT (1 Form C) | SPDT (1 Form C) |
| Contact Rating (Current) | 10 A | 10 A |
| Switching Voltage | 250VAC, 125VDC - Max | 250VAC, 125VDC - Max |
| Coil Current | 30 mA | 30 mA |
| Coil Resistance | 400 Ohms | 400 Ohms |
| Mounting Type | Through Hole | Through Hole |
| Termination Style | PC Pin | PC Pin |
| Operating Temperature Range | -25°C ~ 85°C | -25°C ~ 85°C |
| Contact Material | Silver Tin Oxide (AgSnO) | Silver Tin Oxide (AgSnO) |
| Seal Rating | Sealed - Fully | Sealed - Fully |
| Coil Type | Non Latching | Non Latching |
| Coil Insulation | Class B | Class B |
| Must Operate Voltage | 9 VDC | 9 VDC |
| Must Release Voltage | 1.2 VDC | 1.2 VDC |
| Operate Time | 10 ms | 10 ms |
| Release Time | 5 ms | 5 ms |
| Product Status | Active | Active |
| RoHS Status | RoHS Compliant | ROHS3 Compliant |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8536.41.0050 | 8536.41.0050 |
| Packaging | Tube | Tray |
| Inventory Status | 987 Pcs New Original In Stock | 3444 Pcs New Original In Stock |
Engineering Selection Recommendations
Both the G5LE-14-AP3-36 DC12 and G5LE-14-36 DC12 are active production components from Omron Electronics Inc-EMC Div with identical electrical and mechanical specifications. Selection between these parts should be based on:
- Packaging requirements: The G5LE-14-AP3-36 DC12 is supplied in tube packaging, while the G5LE-14-36 DC12 is supplied in tray packaging. Choose based on assembly line handling and storage needs.
- Inventory availability: The G5LE-14-36 DC12 has higher stock levels (3444 units vs. 987 units), which may support shorter lead times for high-volume orders.
- Compliance requirements: The G5LE-14-36 DC12 carries ROHS3 compliance certification, while the G5LE-14-AP3-36 DC12 carries RoHS compliance. Both meet regulatory requirements; selection depends on specific regional or customer compliance mandates.
Frequently Asked Questions (FAQ)
Q: Can G5LE-14-36 DC12 be used as a direct replacement for G5LE-14-AP3-36 DC12?
A: Yes. Both parts are electrically and mechanically identical. The only differences are packaging format (tube vs. tray) and RoHS certification level. These differences do not affect circuit functionality or performance.
Q: What is the difference between tube and tray packaging?
A: Tube packaging is typically used for manual assembly or smaller batch quantities, while tray packaging is optimized for automated pick-and-place assembly systems. The relay itself is identical in both formats.
Q: Are there any compatibility concerns when switching between these part numbers?
A: No. Both parts share identical coil voltage (12VDC), contact form (SPDT), current rating (10A), switching voltage (250VAC/125VDC), and all other electrical and mechanical parameters. PCB footprints and pin configurations are identical.
Q: What does ROHS3 compliance mean compared to RoHS compliance?
A: ROHS3 represents the most current RoHS directive implementation. Both certifications confirm the absence of restricted hazardous substances. Selection between them depends on customer or regional requirements; both are compliant with current environmental regulations.
Q: Can these relays be used interchangeably in existing designs?
A: Yes. The electrical specifications, operating characteristics, and physical dimensions are identical. No circuit redesign or PCB modification is required when substituting between these part numbers.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts