G2R-2-SN-AC120 Equivalent & Substitute Parts

Part Overview

The G2R-2-SN-AC120 is a general purpose relay manufactured by Omron Electronics Inc-EMC Div, featuring DPDT (2 Form C) contact configuration with 5A contact rating and 120VAC coil voltage. This socketable relay includes a lighted indicator and is designed for plug-in termination applications. The part is currently classified as obsolete, making identification of active equivalent substitutes essential for ongoing system maintenance and new design implementations.

Substiute Parts

G2R-2-SN-AC120
Omron Electronics Inc-EMC DivIn Stock: 1158G2R-2-SN-AC120 Datasheet
G2R-2-SN-AC120
Current Part
G2R-2-SN AC120(S)
Omron Automation and SafetyIn Stock: 808G2R-2-SN AC120(S) Datasheet
G2R-2-SN AC120(S)
Parametric Equivalent

Key Parameters

Parameter Value
Coil Voltage 120VAC
Contact Form DPDT (2 Form C)
Contact Rating (Current) 5 A
Switching Voltage 380VAC, 125VDC - Max
Coil Current 7.5 mA
Coil Type Non Latching
Mounting Type Socketable
Termination Style Plug In
Must Operate Voltage 96 VAC
Must Release Voltage 36 VAC
Operate Time 15 ms
Release Time 15 ms
Operating Temperature Range -40°C ~ 70°C
Coil Resistance 6.5 kOhms
Features Lighted Indicator
Series G2RS

Substitute Part Grouping Explanation

Substitution of the G2R-2-SN-AC120 is determined by strict equivalence across the following critical parameters:

  • Coil Voltage: 120VAC (exact match required)
  • Contact Configuration: DPDT (2 Form C) with 5A rating
  • Switching Voltage Capability: 380VAC, 125VDC maximum
  • Coil Characteristics: 7.5 mA coil current, 6.5 kOhms resistance, non-latching operation
  • Operational Thresholds: Must operate at 96VAC minimum, must release at 36VAC maximum
  • Response Timing: 15 ms operate and release times
  • Mounting and Termination: Socketable mounting with plug-in termination
  • Temperature Range: -40°C to 70°C operating envelope

The substitute part G2R-2-SN AC120(S) maintains identical electrical and mechanical specifications across all parameters listed above, ensuring direct functional equivalence.

Parameter Comparison

Parameter G2R-2-SN-AC120 G2R-2-SN AC120(S) Match Status
Manufacturer Omron Electronics Inc-EMC Div Omron Automation and Safety Same OEM
Series G2RS G2RS Identical
Coil Voltage 120VAC 120VAC Identical
Contact Form DPDT (2 Form C) DPDT (2 Form C) Identical
Contact Rating (Current) 5 A 5 A Identical
Switching Voltage 380VAC, 125VDC - Max 380VAC, 125VDC - Max Identical
Coil Current 7.5 mA 7.5 mA Identical
Coil Type Non Latching Non Latching Identical
Mounting Type Socketable Socketable Identical
Termination Style Plug In Plug In Identical
Must Operate Voltage 96 VAC 96 VAC Identical
Must Release Voltage 36 VAC 36 VAC Identical
Operate Time 15 ms 15 ms Identical
Release Time 15 ms 15 ms Identical
Operating Temperature Range -40°C ~ 70°C -40°C ~ 70°C Identical
Coil Resistance 6.5 kOhms 6.5 kOhms Identical
Features Lighted Indicator Lighted Indicator Identical
Product Status Obsolete Active Substitute is active
RoHS Status RoHS non-compliant ROHS3 Compliant Substitute offers improved compliance
REACH Status REACH Unaffected REACH Affected Substitute subject to REACH

Engineering Selection Recommendations

The G2R-2-SN AC120(S) is the direct functional equivalent for the obsolete G2R-2-SN-AC120. Selection of the substitute part is based on the following factors:

Product Status: The original part is classified as obsolete, while the substitute maintains active product status, ensuring continued availability and manufacturer support.

Regulatory Compliance: The substitute part achieves ROHS3 compliance, whereas the original part is non-compliant. For applications subject to RoHS requirements, the substitute part satisfies regulatory mandates. The substitute is REACH Affected, indicating it is subject to REACH chemical substance regulations, whereas the original part is REACH Unaffected.

Electrical and Mechanical Equivalence: All critical parameters—coil voltage, contact configuration, current ratings, switching voltage capability, timing characteristics, and operating temperature range—are identical between the main part and substitute.

Packaging and Availability: The substitute is available in bulk packaging with confirmed inventory of 745 pieces in stock, compared to 1126 pieces of the obsolete original part.

Frequently Asked Questions (FAQ)

Q: Can G2R-2-SN AC120(S) be used as a direct replacement for G2R-2-SN-AC120?

A: Yes. The substitute part maintains identical electrical specifications across all critical parameters including coil voltage, contact configuration, current rating, switching voltage, timing, and operating temperature range. Physical mounting and termination are also identical, enabling direct socket compatibility.

Q: What is the difference between the two part numbers?

A: The primary differences are product status and regulatory compliance. The G2R-2-SN AC120(S) is an active product with ROHS3 compliance, while the original G2R-2-SN-AC120 is obsolete and RoHS non-compliant. All functional electrical and mechanical parameters are identical.

Q: Are there any compatibility concerns with existing socket installations?

A: No. Both parts feature identical socketable mounting and plug-in termination, ensuring mechanical and electrical compatibility with existing relay sockets and circuit board layouts.

Q: Does the substitute part meet current regulatory requirements?

A: The G2R-2-SN AC120(S) achieves ROHS3 compliance and is subject to REACH regulations, making it suitable for applications requiring current environmental and chemical substance compliance standards.

Q: What is the coil current requirement for both parts?

A: Both the original and substitute parts require 7.5 mA coil current with a coil resistance of 6.5 kOhms at 120VAC, ensuring identical power supply and control circuit requirements.

Q: Are the operating and release times identical?

A: Yes. Both parts operate and release in 15 milliseconds, maintaining identical switching response characteristics for timing-critical applications.

Request Quote (Ships tomorrow)