Request Quote
(Ships tomorrow)
Omron G2A-434A DC12 Equivalent & Substitute Parts
Part Overview
The Omron G2A-434A DC12 is a general purpose relay with 4PDT (4 Form C) contact configuration, rated for 500 mA at 12VDC coil voltage. This socketable relay is designed for applications requiring multiple independent switching circuits with moderate current handling. The G2A-434A DC12 is classified as obsolete, making identification of suitable substitute components necessary for ongoing system support and new design implementations.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Coil Voltage | 12VDC |
| Contact Form | 4PDT (4 Form C) |
| Contact Rating (Current) | 500 mA |
| Switching Voltage | 250VAC, 125VDC - Max |
| Coil Type | Non Latching |
| Mounting Type | Socketable |
| Termination Style | Plug In |
| Operating Temperature Range | -10°C ~ 40°C |
| Coil Resistance | 136 Ohms |
| Must Operate Voltage | 9.6 VDC |
| Must Release Voltage | 1.2 VDC |
Substitute Part Grouping Explanation
Substitution of the G2A-434A DC12 is determined by the following critical parameters:
Mandatory Matching Parameters:
- Coil voltage: 12VDC
- Contact form: 4PDT (4 Form C)
- Coil type: Non Latching
- Switching voltage rating: 250VAC, 125VDC - Max
- Must operate voltage: 9.6 VDC
- Must release voltage: 1.2 VDC
Allowable Variation Parameters:
- Contact rating current: Equal to or greater than 500 mA
- Mounting type: Different mounting types acceptable if circuit board layout permits
- Termination style: Different termination acceptable if socket compatibility or PCB design allows
- Operating temperature range: May be extended beyond -10°C ~ 40°C
- Coil current: May vary within acceptable design margins
- Operate/Release time: May vary within acceptable application timing requirements
The Omron MYQ4Z DC12 meets all mandatory matching parameters while providing enhanced specifications in contact current rating (1 A vs. 500 mA) and extended operating temperature range (-55°C ~ 60°C vs. -10°C ~ 40°C).
Parameter Comparison
| Parameter | G2A-434A DC12 (Main Part) | MYQ4Z DC12 (Substitute) |
|---|---|---|
| Manufacturer | Omron Automation and Safety | Omron Automation and Safety |
| Coil Voltage | 12VDC | 12VDC |
| Contact Form | 4PDT (4 Form C) | 4PDT (4 Form C) |
| Contact Rating (Current) | 500 mA | 1 A |
| Switching Voltage | 250VAC, 125VDC - Max | 250VAC, 125VDC - Max |
| Coil Current | 88 mA | 75 mA |
| Coil Type | Non Latching | Non Latching |
| Mounting Type | Socketable | Through Hole |
| Termination Style | Plug In | PC Pin |
| Must Operate Voltage | 9.6 VDC | 9.6 VDC |
| Must Release Voltage | 1.2 VDC | 1.2 VDC |
| Operate Time | 15 ms | 20 ms |
| Release Time | 15 ms | 20 ms |
| Operating Temperature Range | -10°C ~ 40°C | -55°C ~ 60°C |
| Contact Material | Silver Palladium (AgPd), Gold (Au) | Silver (Ag), Gold (Au) |
| Coil Resistance | 136 Ohms | 160 Ohms |
| Product Status | Obsolete | Active |
| Seal Rating | Not specified | Sealed - Fully |
| RoHS Status | Not specified | RoHS Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) |
Engineering Selection Recommendations
The Omron MYQ4Z DC12 is a suitable substitute for the obsolete G2A-434A DC12 based on the following engineering criteria:
Functional Equivalence: Both relays share identical coil voltage (12VDC), contact configuration (4PDT), switching voltage rating (250VAC, 125VDC - Max), and coil actuation thresholds (9.6 VDC must operate, 1.2 VDC must release). These parameters ensure equivalent electrical performance in the switching circuit.
Enhanced Specifications: The MYQ4Z DC12 provides higher contact current rating (1 A vs. 500 mA), extended operating temperature range (-55°C ~ 60°C vs. -10°C ~ 40°C), and full sealing with RoHS compliance. These enhancements support broader application requirements without performance degradation.
Product Status: The MYQ4Z DC12 maintains active product status with full manufacturer support, ensuring long-term availability and supply chain continuity compared to the obsolete G2A-434A DC12.
Design Considerations: The MYQ4Z DC12 uses through-hole PC pin termination instead of socketable plug-in mounting. Circuit board redesign or adapter solutions may be required for direct mechanical replacement. Coil resistance variation (160 Ohms vs. 136 Ohms) and slightly increased switching times (20 ms vs. 15 ms) are within acceptable engineering tolerances for most general purpose relay applications.
Frequently Asked Questions (FAQ)
Q: Can the MYQ4Z DC12 directly replace the G2A-434A DC12 without circuit modifications?
A: Electrical substitution is valid. The MYQ4Z DC12 meets all mandatory electrical parameters. However, mechanical substitution requires evaluation of the mounting interface. The G2A-434A DC12 uses socketable plug-in termination while the MYQ4Z DC12 uses through-hole PC pins. Direct socket replacement is not possible without adapter hardware or PCB redesign.
Q: What is the impact of the 20 ms switching time on the MYQ4Z DC12 versus the 15 ms on the G2A-434A DC12?
A: The 5 ms difference in operate and release time is a minor variation typical between relay series. For general purpose switching applications, this difference is generally not significant. Applications with strict timing requirements below 20 ms should be evaluated against specific circuit performance needs.
Q: Does the higher contact current rating (1 A) of the MYQ4Z DC12 affect compatibility?
A: No. Higher contact current rating provides additional design margin and is fully backward compatible. Applications designed for 500 mA operation will function within the MYQ4Z DC12 specifications without modification.
Q: Are there compliance or certification differences between these relays?
A: The MYQ4Z DC12 is RoHS compliant and fully sealed, providing enhanced environmental protection. Both relays share identical MSL rating (1 - Unlimited) and ECCN/HTSUS classifications. The MYQ4Z DC12 offers superior compliance posture for modern manufacturing and environmental standards.
Q: What is the significance of the different contact materials?
A: The G2A-434A DC12 uses Silver Palladium (AgPd) and Gold (Au) contacts, while the MYQ4Z DC12 uses Silver (Ag) and Gold (Au). Both material compositions are suitable for general purpose switching. Contact material selection does not prevent substitution for standard applications.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts