Request Quote
(Ships tomorrow)
FSFR1600XS Equivalent & Substitute Parts
Part Overview
The FSFR1600XS is an offline switching half-bridge converter IC manufactured by onsemi, designed for isolated power management applications with up to 300kHz switching frequency and 160W power handling capability. The part operates with a 500V breakdown voltage and includes integrated fault protection features. This component is classified as obsolete, making equivalent and substitute parts necessary for ongoing design support and procurement continuity.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | FSFR1600XS |
| Manufacturer | onsemi |
| Category | Power Management (PMIC) |
| Description | IC OFFLINE SW HALF-BRIDGE 9SIP |
| Topology | Half-Bridge |
| Voltage - Breakdown | 500V |
| Voltage - Supply (Vcc/Vdd) | 10V ~ 25V |
| Voltage - Start Up | 12.5V |
| Frequency - Switching | Up to 300kHz |
| Power (Watts) | 160W |
| Duty Cycle | 50% |
| Output Isolation | Isolated |
| Internal Switch(s) | Yes |
| Fault Protection | Current Limiting, Over Temperature, Over Voltage |
| Control Features | Frequency Control |
| Operating Temperature | -40°C ~ 130°C (TJ) |
| Package / Case | 10-SIP Module, 9 Leads, Formed Leads |
| Mounting Type | Through Hole |
| Product Status | Obsolete |
| RoHS Status | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitute parts for the FSFR1600XS are qualified based on the following critical parameters that determine functional compatibility:
Core Electrical Parameters (Must Match):
- Topology: Half-Bridge
- Voltage - Breakdown: 500V
- Voltage - Supply (Vcc/Vdd): 10V ~ 25V
- Voltage - Start Up: 12.5V
- Frequency - Switching: Up to 300kHz
- Duty Cycle: 50%
- Output Isolation: Isolated
- Internal Switch(s): Yes
- Fault Protection: Current Limiting, Over Temperature, Over Voltage
- Control Features: Frequency Control
- Operating Temperature: -40°C ~ 130°C (TJ)
Mechanical Parameters (Must Match):
- Package / Case: 10-SIP Module, 9 Leads, Formed Leads
- Mounting Type: Through Hole
- Supplier Device Package: 9-SIP
Variable Parameters (Allowed to Differ):
- Power (Watts): 160W baseline; substitutes range from 200W to 400W
- Manufacturer: onsemi or Fairchild Semiconductor
- Product Status: Obsolete or Active
- Packaging: Tube or unspecified
- Lead Forming: Standard or L-forming variant
All substitute parts maintain identical electrical specifications and package footprint compatibility while offering equal or higher power ratings and varying product availability status.
Parameter Comparison
| Parameter | FSFR1600XS | FSFR1700XS | FSFR1700XSL | FSFR1800XS | FSFR1800XSL | FSFR2100XS | FSFR2100XSL |
|---|---|---|---|---|---|---|---|
| Manufacturer | onsemi | Fairchild Semiconductor | Fairchild Semiconductor | onsemi | Fairchild Semiconductor | onsemi | onsemi |
| Topology | Half-Bridge | Half-Bridge | Half-Bridge | Half-Bridge | Half-Bridge | Half-Bridge | Half-Bridge |
| Voltage - Breakdown | 500V | 500V | 500V | 500V | 500V | 500V | 500V |
| Voltage - Supply (Vcc/Vdd) | 10V ~ 25V | 10V ~ 25V | 10V ~ 25V | 10V ~ 25V | 10V ~ 25V | 10V ~ 25V | 10V ~ 25V |
| Voltage - Start Up | 12.5V | 12.5V | 12.5V | 12.5V | 12.5V | 12.5V | 12.5V |
| Frequency - Switching | Up to 300kHz | Up to 300kHz | Up to 300kHz | Up to 300kHz | Up to 300kHz | Up to 300kHz | Up to 300kHz |
| Power (Watts) | 160W | 200W | 200W | 260W | Not Specified | 400W | 400W |
| Duty Cycle | 50% | 50% | 50% | 50% | 50% | 50% | 50% |
| Output Isolation | Isolated | Isolated | Isolated | Isolated | Isolated | Isolated | Isolated |
| Internal Switch(s) | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Fault Protection | Current Limiting, Over Temperature, Over Voltage | Current Limiting, Over Temperature, Over Voltage | Current Limiting, Over Temperature, Over Voltage | Current Limiting, Over Temperature, Over Voltage | Current Limiting, Over Temperature, Over Voltage | Current Limiting, Over Temperature, Over Voltage | Current Limiting, Over Temperature, Over Voltage |
| Control Features | Frequency Control | Frequency Control | Frequency Control | Frequency Control | Frequency Control | Frequency Control | Frequency Control |
| Operating Temperature | -40°C ~ 130°C (TJ) | -40°C ~ 130°C (TJ) | -40°C ~ 130°C (TJ) | -40°C ~ 130°C (TJ) | -40°C ~ 130°C (TJ) | -40°C ~ 130°C (TJ) | -40°C ~ 130°C (TJ) |
| Package / Case | 10-SIP Module, 9 Leads, Formed Leads | 10-SSIP Module, 9 Leads, Formed Leads | 10-SIP Module, 9 Leads, Formed Leads | 10-SIP Module, 9 Leads, Formed Leads | 10-SIP Module, 9 Leads, Formed Leads | 10-SIP Module, 9 Leads, Formed Leads | 10-SIP Module, 9 Leads, Formed Leads |
| Mounting Type | Through Hole | Through Hole | Through Hole | Through Hole | Through Hole | Through Hole | Through Hole |
| Product Status | Obsolete | Active | Active | Obsolete | Active | Obsolete | Obsolete |
| RoHS Status | ROHS3 Compliant | Not Specified | Not Specified | ROHS3 Compliant | Not Specified | ROHS3 Compliant | ROHS3 Compliant |
Engineering Selection Recommendations
For Active Product Status Requirement: Select FSFR1700XS or FSFR1700XSL for designs requiring currently manufactured components. Both parts are classified as Active and maintain full electrical and mechanical compatibility with FSFR1600XS. FSFR1700XS offers standard lead forming, while FSFR1700XSL provides L-forming variant for specific PCB layout requirements. Both deliver 200W power rating, exceeding the 160W baseline.
For Higher Power Capacity: FSFR1800XS and FSFR2100XS provide 260W and 400W ratings respectively, suitable for applications requiring increased power headroom. FSFR1800XS is available from onsemi (Obsolete status), while FSFR2100XS offers the highest power capacity at 400W. FSFR2100XSL provides the L-forming variant of the 400W option.
For RoHS3 Compliance Assurance: All onsemi-manufactured parts (FSFR1600XS, FSFR1800XS, FSFR2100XS, FSFR2100XSL) carry explicit ROHS3 Compliant certification. Fairchild Semiconductor parts (FSFR1700XS, FSFR1700XSL, FSFR1800XSL) do not specify RoHS status in provided data.
For Lead Forming Variants: Standard forming: FSFR1700XS, FSFR1800XS, FSFR2100XS L-forming: FSFR1700XSL, FSFR1800XSL, FSFR2100XSL
Frequently Asked Questions (FAQ)
Q: Can FSFR1700XS directly replace FSFR1600XS in existing designs? A: Yes. FSFR1700XS maintains identical electrical specifications (500V breakdown, 10V-25V supply, 300kHz switching, 50% duty cycle, isolated output) and package footprint (10-SIP, 9 leads, through-hole). The 200W rating exceeds the 160W baseline, providing additional capacity margin.
Q: What is the difference between standard and L-forming lead variants? A: L-forming (XSL suffix) provides bent leads suitable for specific PCB mounting configurations. Standard forming (XS suffix) uses straight leads. Both variants maintain identical electrical performance and 9-SIP package compatibility. Selection depends on PCB layout and lead insertion requirements.
Q: Why are some substitute parts listed as Obsolete? A: Product status reflects manufacturer lifecycle classification at the time of data compilation. Obsolete parts may remain available through inventory channels. For new designs requiring long-term supply assurance, prioritize Active status parts: FSFR1700XS or FSFR1700XSL.
Q: Are all substitute parts ROHS3 compliant? A: onsemi-manufactured substitutes (FSFR1800XS, FSFR2100XS, FSFR2100XSL) carry explicit ROHS3 Compliant certification. Fairchild Semiconductor parts do not specify RoHS status in available documentation. Verify compliance requirements with component suppliers for Fairchild variants.
Q: What power rating should I select for my application? A: Select based on actual circuit power requirements with appropriate design margin. FSFR1700XS/FSFR1700XSL (200W) provides 25% headroom over FSFR1600XS baseline. FSFR1800XS (260W) and FSFR2100XS/FSFR2100XSL (400W) offer progressively higher capacity for demanding applications.
Q: Are there any differences in fault protection between substitute parts? A: All substitute parts include identical fault protection: Current Limiting, Over Temperature, and Over Voltage protection. Frequency Control is standard across all variants.
Q: Can I use FSFR2100XS in place of FSFR1600XS? A: Yes. FSFR2100XS maintains all core electrical and mechanical specifications while providing 400W power capacity. The higher rating introduces no compatibility issues for designs originally specified at 160W, though thermal management design may require adjustment for the increased power capability.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts