Part Overview
The FR301 is a general-purpose rectifier diode manufactured by SMC Diode Solutions, rated for 50 V DC reverse voltage and 3 A average rectified current in a DO-201AD axial through-hole package. This part is classified as obsolete, making identification of equivalent and substitute components necessary for ongoing design support and procurement continuity. Substitute parts must maintain electrical compatibility across voltage, current, and thermal specifications while accommodating the through-hole DO-201AD package format.
Substiute Parts
Key Parameters
| Parameter | Value | Unit |
|---|---|---|
| Voltage - DC Reverse (Vr) (Max) | 50 | V |
| Current - Average Rectified (Io) | 3 | A |
| Voltage - Forward (Vf) (Max) @ If | 1.3 | V @ 3 A |
| Reverse Recovery Time (trr) | 150 | ns |
| Current - Reverse Leakage @ Vr | 5 | µA @ 50 V |
| Mounting Type | Through Hole | — |
| Package / Case | DO-201AD, Axial | — |
| Operating Temperature - Junction | -65 to 150 | °C |
| Technology | Standard | — |
Substitute Part Grouping Explanation
Substitute parts for the FR301 are grouped based on strict electrical and mechanical compatibility criteria. All substitute candidates must satisfy the following requirements:
Mandatory Compatibility Parameters:
- Voltage - DC Reverse (Vr) (Max): 50 V minimum
- Current - Average Rectified (Io): 3 A minimum
- Package / Case: DO-201AD, Axial (through-hole)
- Mounting Type: Through Hole
- Technology: Standard
Acceptable Variation Parameters:
- Voltage - Forward (Vf): Equal to or lower than 1.3 V @ rated current
- Reverse Recovery Time (trr): Equal to or lower than 150 ns
- Current - Reverse Leakage: Equal to or lower than 5 µA @ 50 V
- Operating Temperature - Junction: Minimum -55°C acceptable (FR301 specifies -65°C)
- Capacitance @ Vr: Variation acceptable within standard manufacturing tolerances
Product Status Consideration: Direct substitutes must be in Active product status to ensure long-term availability and supply chain continuity.
Parameter Comparison
| Parameter | FR301 (Main) | FR301G | FR301G A0G | SF31GHB0G | SF61G A0G |
|---|---|---|---|---|---|
| Manufacturer | SMC Diode Solutions | Taiwan Semiconductor Corporation | Taiwan Semiconductor Corporation | Taiwan Semiconductor Corporation | Taiwan Semiconductor Corporation |
| Product Status | Obsolete | Active | Active | Active | Active |
| Voltage - DC Reverse (Vr) (Max) | 50 V | 50 V | 50 V | 50 V | 50 V |
| Current - Average Rectified (Io) | 3 A | 3 A | 3 A | 3 A | 6 A |
| Voltage - Forward (Vf) (Max) @ If | 1.3 V @ 3 A | 1.3 V @ 3 A | 1.3 V @ 3 A | 950 mV @ 3 A | 975 mV @ 6 A |
| Reverse Recovery Time (trr) | 150 ns | 150 ns | 150 ns | 35 ns | 35 ns |
| Current - Reverse Leakage @ Vr | 5 µA @ 50 V | 5 µA @ 50 V | 5 µA @ 50 V | 5 µA @ 50 V | 5 µA @ 50 V |
| Capacitance @ Vr, F | 60 pF @ 4V, 1MHz | 30 pF @ 4V, 1MHz | 30 pF @ 4V, 1MHz | 80 pF @ 4V, 1MHz | 100 pF @ 4V, 1MHz |
| Operating Temperature - Junction | -65 to 150 °C | -55 to 150 °C | -55 to 150 °C | -55 to 150 °C | -55 to 150 °C |
| Package / Case | DO-201AD, Axial | DO-201AD, Axial | DO-201AD, Axial | DO-201AD, Axial | DO-201AD, Axial |
| RoHS Status | — | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) | 1 (Unlimited) | 1 (Unlimited) | 1 (Unlimited) |
Engineering Selection Recommendations
Primary Substitute: FR301G and FR301G A0G
The FR301G and FR301G A0G, both manufactured by Taiwan Semiconductor Corporation, are direct electrical equivalents to the FR301. Both parts maintain identical voltage, current, and reverse recovery specifications. These parts are in Active product status, ensuring supply chain continuity. Both are ROHS3 compliant, meeting modern regulatory requirements. The primary difference is a reduced minimum operating temperature of -55°C compared to the FR301's -65°C specification; this is acceptable for applications not requiring sub-55°C operation. Capacitance is reduced to 30 pF, which may improve high-frequency performance characteristics.
Secondary Substitute: SF31GHB0G
The SF31GHB0G is electrically compatible with the FR301 at the 3 A current rating. This part offers improved performance characteristics including lower forward voltage (950 mV vs. 1.3 V) and significantly faster reverse recovery time (35 ns vs. 150 ns). The SF31GHB0G carries AEC-Q101 automotive qualification and is suitable for applications requiring enhanced switching performance. Operating temperature range is -55 to 150°C. This part is appropriate for designs where reduced power dissipation and faster switching are beneficial.
Tertiary Substitute: SF61G A0G
The SF61G A0G is rated for 6 A average rectified current, exceeding the FR301's 3 A specification. This part is suitable for applications where current headroom is required or where design consolidation across multiple current ratings is advantageous. Electrical characteristics include 975 mV forward voltage and 35 ns reverse recovery time. The higher current rating does not preclude use in 3 A applications; the part will operate within safe margins. Operating temperature range is -55 to 150°C.
All substitute parts maintain the DO-201AD axial through-hole package format, ensuring mechanical compatibility with existing PCB layouts and assembly processes.
Frequently Asked Questions (FAQ)
Q: Can FR301G be used as a direct replacement for FR301?
A: Yes. The FR301G maintains identical voltage (50 V), current (3 A), forward voltage (1.3 V @ 3 A), and reverse recovery time (150 ns) specifications. The primary difference is the minimum operating temperature of -55°C versus -65°C for the FR301. For applications operating above -55°C, FR301G is a direct substitute. Both parts use the DO-201AD package.
Q: What is the difference between FR301G and SF31GHB0G?
A: Both parts are rated for 50 V and 3 A. The SF31GHB0G offers superior performance with lower forward voltage (950 mV vs. 1.3 V) and faster reverse recovery time (35 ns vs. 150 ns). The SF31GHB0G includes AEC-Q101 automotive qualification. Selection depends on whether improved switching performance and reduced power dissipation are required for the application.
Q: Can SF61G A0G replace FR301 in a 3 A circuit?
A: Yes. The SF61G A0G is rated for 6 A, which exceeds the FR301's 3 A requirement. The part will operate safely in a 3 A application with additional current margin. All other electrical parameters (50 V reverse voltage, forward voltage, recovery time) are compatible. The DO-201AD package remains unchanged.
Q: Are all substitute parts ROHS3 compliant?
A: Yes. FR301G, FR301G A0G, SF31GHB0G, and SF61G A0G are all ROHS3 compliant. The original FR301 does not specify RoHS status. All substitute parts meet modern environmental and regulatory requirements.
Q: What is the minimum operating temperature for substitute parts?
A: All substitute parts (FR301G, FR301G A0G, SF31GHB0G, SF61G A0G) are rated for -55°C minimum junction temperature, compared to -65°C for the FR301. For applications requiring operation below -55°C, the FR301 specification must be maintained or alternative parts must be evaluated.
Q: Do all substitute parts use the same DO-201AD package?
A: Yes. All substitute parts use the DO-201AD axial through-hole package. No PCB layout or assembly process modifications are required for mechanical compatibility.
Q: What is the inventory status of substitute parts?
A: FR301G: 1123 pieces in stock. FR301G A0G: 1029 pieces in stock. SF31GHB0G: 932 pieces in stock. SF61G A0G: 761 pieces in stock. All parts are available as new original stock.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts