FR207-AP Equivalent & Substitute Parts

Part Overview

The FR207-AP is a general-purpose rectifier diode manufactured by Micro Commercial Co, rated for 1000 V DC reverse voltage and 2 A average rectified current in a DO-15 through-hole package. This component is classified as obsolete, necessitating identification of active equivalent alternatives for new designs and ongoing production requirements. Substitute parts must maintain identical electrical performance characteristics and mechanical compatibility to ensure direct replacement capability.

Substiute Parts

FR207-AP
Micro Commercial CoIn Stock: 1093FR207-AP Datasheet
FR207-AP
Current Part
FR207GP-AP
Micro Commercial CoIn Stock: 1143FR207GP-AP Datasheet
FR207GP-AP
Direct
FR207GB-G
Comchip TechnologyIn Stock: 1161FR207GB-G Datasheet
FR207GB-G
Parametric Equivalent

Key Parameters

Parameter Value Unit
Voltage - DC Reverse (Vr) (Max) 1000 V
Current - Average Rectified (Io) 2 A
Voltage - Forward (Vf) (Max) @ If 1.3 @ 2 A V
Reverse Recovery Time (trr) 500 ns
Current - Reverse Leakage @ Vr 5 @ 1000 V µA
Mounting Type Through Hole -
Package / Case DO-204AC, DO-15, Axial -
Operating Temperature - Junction -55 to 150 °C
Technology Standard -
Speed Classification Fast Recovery ≤ 500ns, > 200mA (Io) -

Substitute Part Grouping Explanation

Substitute parts for the FR207-AP are classified based on strict electrical and mechanical parameter matching. All substitute candidates must satisfy the following criteria:

Electrical Parameters (Mandatory Match):

  • Voltage - DC Reverse (Vr) (Max): 1000 V
  • Current - Average Rectified (Io): 2 A
  • Voltage - Forward (Vf) (Max) @ If: 1.3 V @ 2 A
  • Reverse Recovery Time (trr): 500 ns
  • Current - Reverse Leakage @ Vr: 5 µA @ 1000 V
  • Speed Classification: Fast Recovery ≤ 500ns, > 200mA (Io)

Mechanical Parameters (Mandatory Match):

  • Mounting Type: Through Hole
  • Package / Case: DO-204AC, DO-15, Axial
  • Operating Temperature - Junction: -55°C to 150°C

Compliance Parameters:

  • RoHS Status: ROHS3 Compliant
  • Technology: Standard

Substitutes are identified as either direct manufacturer alternatives (same manufacturer, active product status) or parametric equivalents (different manufacturer, identical electrical specifications).

Parameter Comparison

Parameter FR207-AP (Micro Commercial Co) FR207GP-AP (Micro Commercial Co) FR207GB-G (Comchip Technology)
Voltage - DC Reverse (Vr) (Max) 1000 V 1000 V 1000 V
Current - Average Rectified (Io) 2 A 2 A 2 A
Voltage - Forward (Vf) (Max) @ If 1.3 V @ 2 A 1.3 V @ 2 A 1.3 V @ 2 A
Reverse Recovery Time (trr) 500 ns 500 ns 500 ns
Current - Reverse Leakage @ Vr 5 µA @ 1000 V 5 µA @ 1000 V 5 µA @ 1000 V
Speed Classification Fast Recovery ≤ 500ns, > 200mA (Io) Fast Recovery ≤ 500ns, > 200mA (Io) Fast Recovery ≤ 500ns, > 200mA (Io)
Mounting Type Through Hole Through Hole Through Hole
Package / Case DO-204AC, DO-15, Axial DO-204AC, DO-15, Axial DO-204AC, DO-15, Axial
Operating Temperature - Junction -55°C to 150°C -55°C to 150°C -55°C to 150°C
Product Status Obsolete Active Active
RoHS Status ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited)

Engineering Selection Recommendations

FR207GP-AP (Micro Commercial Co) is the primary substitute for FR207-AP. This part maintains identical electrical and mechanical specifications while offering active product status. As a direct manufacturer alternative from Micro Commercial Co, FR207GP-AP provides continuity in supply chain management and design documentation. The part is ROHS3 compliant and carries unlimited moisture sensitivity rating, matching the original component's compliance profile.

FR207GB-G (Comchip Technology) serves as a parametric equivalent substitute. This part satisfies all mandatory electrical parameters and mechanical requirements, including voltage rating, current capacity, recovery time, and leakage characteristics. FR207GB-G is supplied in Tape & Box packaging and maintains active product status with ROHS3 compliance. The parametric equivalence classification indicates full functional interchangeability based on electrical and thermal specifications.

Both substitute parts are suitable for direct replacement in applications currently utilizing FR207-AP. Selection between FR207GP-AP and FR207GB-G depends on supply chain preferences, packaging requirements, and manufacturer qualification protocols.

Frequently Asked Questions (FAQ)

Q: Can FR207GP-AP directly replace FR207-AP in existing designs?

A: Yes. FR207GP-AP is a direct manufacturer substitute with identical electrical specifications, forward voltage characteristics, reverse recovery time, and leakage current. Both components are rated for 1000 V, 2 A operation in DO-15 through-hole packages with -55°C to 150°C junction temperature range. The primary difference is product status: FR207-AP is obsolete while FR207GP-AP is active.

Q: What is the difference between FR207GP-AP and FR207GB-G?

A: FR207GP-AP is manufactured by Micro Commercial Co and represents a direct manufacturer alternative. FR207GB-G is manufactured by Comchip Technology and represents a parametric equivalent. Both parts satisfy identical electrical requirements and mechanical specifications. The distinction lies in manufacturer origin and packaging format: FR207GP-AP uses standard packaging while FR207GB-G is supplied in Tape & Box format.

Q: Are all three parts ROHS3 compliant?

A: Yes. FR207-AP, FR207GP-AP, and FR207GB-G are all ROHS3 compliant with MSL rating of 1 (Unlimited), indicating no moisture sensitivity restrictions during storage and handling.

Q: Can FR207GB-G be used in applications designed for FR207-AP?

A: Yes. FR207GB-G meets all mandatory electrical and mechanical parameters required for FR207-AP substitution. The parametric equivalence classification confirms functional interchangeability. Packaging format differs (Tape & Box versus standard), but this does not affect circuit-level performance.

Q: What parameters must remain identical for substitution?

A: Voltage rating (1000 V), current capacity (2 A), forward voltage (1.3 V @ 2 A), reverse recovery time (500 ns), reverse leakage (5 µA @ 1000 V), mounting type (through hole), package style (DO-15), and operating temperature range (-55°C to 150°C) must all remain unchanged for valid substitution.

Q: Why is FR207-AP classified as obsolete?

A: FR207-AP is marked obsolete in the manufacturer's product lifecycle. Active alternatives FR207GP-AP and FR207GB-G are available to support ongoing production and new design requirements.

Request Quote (Ships tomorrow)