FN5040-410-99 Equivalent & Substitute Parts

Part Overview

The FN5040-410-99 is a three-phase (Delta) EMC/EMI line filter rated for 410 A AC operation with chassis mount configuration and terminal block termination. This component is designed for regenerative motor drive applications requiring single-stage filtering in industrial environments.

The FN5040-410-99 is classified as obsolete. Locating equivalent or substitute components is necessary to maintain system functionality and ensure continued availability for new designs or replacement requirements.

Substiute Parts

FN5040-410-99
Schaffner EMC Inc.In Stock: 861FN5040-410-99 Datasheet
FN5040-410-99
Current Part
FN5420-480-99-E0XXT
Schaffner EMC Inc.In Stock: 779FN5420-480-99-E0XXT Datasheet
FN5420-480-99-E0XXT
MFR Recommended

Key Parameters

Parameter Value
Manufacturer Part Number FN5040-410-99
Manufacturer Schaffner EMC Inc.
Series FN 5040
Product Status Obsolete
Filter Type Three Phase (Delta)
Configuration Single Stage
Current Rating 410 A
Mounting Type Chassis Mount
Termination Style Terminal Block
Inductance 130µH
Operating Temperature Range -25°C ~ 70°C
Applications Regenerative Motor Drive
Approval Agencies cURus
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

The FN5420-480-99-E0XXT is identified as the manufacturer-recommended substitute for the FN5040-410-99. Substitution eligibility is determined by the following parameters:

  • Filter Type: Both components are three-phase (Delta) EMC/EMI line filters
  • Configuration: Both utilize single-stage filtering architecture
  • Mounting Type: Both employ chassis mount configuration
  • Termination Style: Both use terminal block termination
  • Application: Both are rated for regenerative motor drive applications
  • Current Capacity: The substitute (477 A) exceeds the original specification (410 A), providing operational headroom
  • Inductance: The substitute (92µH) differs from the original (130µH), reflecting design optimization in the newer series
  • Operating Temperature: The substitute (-40°C ~ 70°C) extends the lower temperature range compared to the original (-25°C ~ 70°C)
  • Approval Agencies: The substitute carries expanded certifications (CE, cURus, UKCA) versus the original (cURus only)

Parameter Comparison

Parameter FN5040-410-99 FN5420-480-99-E0XXT
Manufacturer Schaffner EMC Inc. Schaffner EMC Inc.
Series FN 5040 FN 5420
Product Status Obsolete Active
Filter Type Three Phase (Delta) Three Phase (Delta)
Configuration Single Stage Single Stage
Current Rating 410 A 477 A
Mounting Type Chassis Mount Chassis Mount
Termination Style Terminal Block Terminal Block
Inductance 130µH 92µH
Operating Temperature Range -25°C ~ 70°C -40°C ~ 70°C
Applications Regenerative Motor Drive Regenerative Motor Drive
Approval Agencies cURus CE, cURus, UKCA
Frequency Operating Range Not specified DC ~ 60Hz
Voltage - Rated AC (Phase to Ground/Neutral) Not specified 480 V
Voltage - Rated AC (Phase to Phase) Not specified 530 V

Engineering Selection Recommendations

The FN5420-480-99-E0XXT is the manufacturer-recommended substitute for the obsolete FN5040-410-99. Selection of the substitute is supported by the following factors:

  • Product Status Alignment: The substitute is active and currently manufactured, ensuring long-term availability and supply chain continuity
  • Functional Equivalence: Both components share identical filter type, configuration, mounting, and termination characteristics required for regenerative motor drive applications
  • Current Capacity: The substitute's 477 A rating accommodates the original 410 A requirement with margin
  • Expanded Certifications: The substitute carries CE, cURus, and UKCA approvals, providing broader regulatory compliance compared to the original cURus-only certification
  • Extended Temperature Range: The substitute operates from -40°C, extending the lower operating boundary relative to the original -25°C specification

Frequently Asked Questions (FAQ)

Q: Can the FN5420-480-99-E0XXT directly replace the FN5040-410-99 in existing installations?

A: Yes. Both components share the same filter type (three-phase Delta), configuration (single stage), mounting method (chassis mount), and termination style (terminal block). The substitute's higher current rating (477 A versus 410 A) and expanded temperature range (-40°C versus -25°C) are compatible with the original application requirements.

Q: What is the significance of the inductance difference between the two parts?

A: The FN5040-410-99 has 130µH inductance while the FN5420-480-99-E0XXT has 92µH. This difference reflects design optimization in the newer FN 5420 series. Both values are appropriate for their respective current ratings and filtering performance in regenerative motor drive applications.

Q: Why does the substitute have voltage ratings specified while the original does not?

A: The FN5420-480-99-E0XXT includes explicit voltage specifications (480 V phase-to-ground/neutral, 530 V phase-to-phase) and frequency range (DC ~ 60Hz). These parameters define the operating envelope for the substitute. The original FN5040-410-99 datasheet does not provide these specifications in the available documentation.

Q: Are there packaging differences between these components?

A: The FN5040-410-99 is packaged as standard, while the FN5420-480-99-E0XXT is supplied in bulk packaging. Both use terminal block termination suitable for industrial chassis mount applications.

Q: What certifications apply to each component?

A: The FN5040-410-99 carries cURus approval. The FN5420-480-99-E0XXT carries CE, cURus, and UKCA approvals, providing compliance for broader geographic and regulatory requirements.

Request Quote (Ships tomorrow)