Part Overview
The FN258P-55-34 is a three-phase (Delta) EMC/EMI line filter rated for 55 A with chassis mount configuration and terminal block termination. This component is designed for inverters and power drive systems operating at DC ~ 60Hz frequencies. The part is classified as Not For New Designs, making identification of functionally equivalent alternatives necessary for ongoing system support and new platform development.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | FN258P-55-34 |
| Manufacturer | Schaffner EMC Inc. |
| Series | FN 258 |
| Filter Type | Three Phase (Delta) |
| Configuration | Two Stage |
| Current Rating | 55 A |
| Voltage - Phase to Ground/Neutral | 277 V |
| Voltage - Phase to Phase | 480 V |
| Frequency - Operating | DC ~ 60Hz |
| Mounting Type | Chassis Mount |
| Termination Style | Terminal Block |
| Operating Temperature | -25°C ~ 100°C |
| Product Status | Not For New Designs |
| RoHS Status | ROHS3 Compliant |
| Approval Agency | CSA, ENEC, UR |
Substitute Part Grouping Explanation
Substitution eligibility for the FN258P-55-34 is determined by the following critical parameters:
- Filter Type: Three Phase (Delta) configuration
- Configuration: Two Stage topology
- Mounting Type: Chassis Mount form factor
- Termination Style: Terminal Block interface
- Frequency Range: DC ~ 60Hz operating capability
- Applications: Inverters and Power Drive Systems compatibility
The FN3288-50-53-C35-R65 qualifies as a substitute based on matching filter type, configuration, mounting, termination, and frequency specifications. Current rating variance (50 A vs. 55 A) and voltage rating differences are acceptable within the substitution framework when system design permits.
Parameter Comparison
| Parameter | FN258P-55-34 | FN3288-50-53-C35-R65 |
|---|---|---|
| Manufacturer | Schaffner EMC Inc. | Schaffner EMC Inc. |
| Filter Type | Three Phase (Delta) | Three Phase (Delta) |
| Configuration | Two Stage | Two Stage |
| Current Rating | 55 A | 50 A |
| Voltage - Phase to Ground/Neutral | 277 V | 305 V |
| Voltage - Phase to Phase | 480 V | 530 V |
| Frequency - Operating | DC ~ 60Hz | DC ~ 60Hz |
| Mounting Type | Chassis Mount | Chassis Mount |
| Termination Style | Terminal Block | Terminal Block |
| Operating Temperature | -25°C ~ 100°C | -40°C ~ 100°C |
| Product Status | Not For New Designs | Active |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| Approval Agency | CSA, ENEC, UR | Not specified in data |
Engineering Selection Recommendations
The FN3288-50-53-C35-R65 is an active product from Schaffner EMC Inc. and represents the primary substitute for the FN258P-55-34. Both components maintain ROHS3 compliance and REACH unaffected status, ensuring regulatory alignment.
The FN3288-50-53-C35-R65 provides an extended operating temperature range (-40°C ~ 100°C vs. -25°C ~ 100°C), offering improved performance in low-temperature environments. The higher voltage ratings (530V phase-to-phase, 305V phase-to-ground) accommodate broader system voltage specifications.
Current rating reduction from 55 A to 50 A requires verification that system load profiles remain within the 50 A specification. The active product status of the FN3288-50-53-C35-R65 ensures ongoing availability and support compared to the Not For New Designs classification of the FN258P-55-34.
Frequently Asked Questions (FAQ)
Q: Can the FN3288-50-53-C35-R65 directly replace the FN258P-55-34 in existing designs?
A: Direct replacement is possible when system current requirements do not exceed 50 A and voltage specifications align with the 530V/305V ratings of the substitute. Mechanical compatibility is confirmed through matching chassis mount and terminal block configurations.
Q: What is the significance of the current rating difference between these parts?
A: The FN258P-55-34 is rated for 55 A while the FN3288-50-53-C35-R65 is rated for 50 A. System designs operating at or below 50 A can use the substitute without derating. Systems requiring the full 55 A capacity must retain the original part or identify alternative solutions.
Q: How do voltage ratings affect substitution?
A: The FN258P-55-34 operates at 480V phase-to-phase and 277V phase-to-ground. The FN3288-50-53-C35-R65 operates at 530V phase-to-phase and 305V phase-to-ground. The substitute accommodates higher voltage systems. Systems operating at the original voltage specifications remain compatible with the substitute.
Q: What is the impact of product status on component selection?
A: The FN258P-55-34 carries a Not For New Designs status, indicating discontinued development support. The FN3288-50-53-C35-R65 maintains Active status, ensuring continued manufacturing, availability, and technical support for new platform development and ongoing production.
Q: Are there packaging or inventory considerations?
A: Both components are supplied in Tray packaging. Current inventory levels are 1042 pcs for the FN258P-55-34 and 1050 pcs for the FN3288-50-53-C35-R65, indicating adequate stock availability for both options.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts