Request Quote
(Ships tomorrow)
FN258HVIT-100-35 Equivalent & Substitute Parts
Part Overview
The FN258HVIT-100-35 is a three-phase delta EMC/EMI line filter rated for 100 A operation with two-stage filtering configuration. This component is designed for chassis mount applications in inverters and power drive systems, operating across DC to 60 Hz frequency range with phase-to-phase voltage rating of 690 V and phase-to-ground voltage rating of 400 V.
This part carries a "Not For New Designs" status, making identification of functionally equivalent alternatives necessary for ongoing system maintenance and new design implementations. The substitute part FN3359-150-28 provides comparable filtering performance with enhanced current capacity and three-stage configuration.
Substiute Parts
Key Parameters
| Parameter | FN258HVIT-100-35 |
|---|---|
| Filter Type | Three Phase (Delta) |
| Configuration | Two Stage |
| Current Rating | 100 A |
| Voltage - Phase to Ground/Neutral | 400 V |
| Voltage - Phase to Phase | 690 V |
| Frequency Range | DC ~ 60 Hz |
| Mounting Type | Chassis Mount |
| Termination Style | Terminal Block |
| Operating Temperature | -25°C ~ 100°C |
| RoHS Status | ROHS3 Compliant |
| Approval Agencies | CSA, ENEC, UR |
Substitute Part Grouping Explanation
Substitution eligibility for the FN258HVIT-100-35 is determined by the following critical parameters:
- Filter topology: Three-phase delta configuration
- Mounting interface: Chassis mount capability
- Operating frequency: DC to 60 Hz compatibility
- Voltage class: Phase-to-phase and phase-to-ground ratings
- Current capacity: Equal or greater than 100 A
- Regulatory compliance: CSA, ENEC, or UR certification
The FN3359-150-28 qualifies as a substitute based on matching filter type, mounting method, frequency range, and regulatory certifications. The substitute provides increased current capacity (150 A) and enhanced filtering stages (three-stage versus two-stage), making it suitable for applications requiring the original part's performance envelope or greater.
Parameter Comparison
| Parameter | FN258HVIT-100-35 | FN3359-150-28 | Compatibility Notes |
|---|---|---|---|
| Filter Type | Three Phase (Delta) | Three Phase (Delta) | Matched |
| Configuration | Two Stage | Three Stage | Substitute offers enhanced filtering |
| Current Rating | 100 A | 150 A | Substitute rated higher |
| Voltage - Phase to Ground/Neutral | 400 V | 300 V | Substitute rated lower |
| Voltage - Phase to Phase | 690 V | 520 V | Substitute rated lower |
| Frequency Range | DC ~ 60 Hz | DC ~ 60 Hz | Matched |
| Mounting Type | Chassis Mount | Chassis Mount | Matched |
| Termination Style | Terminal Block | Threaded Post (M10) | Different interface |
| Operating Temperature | -25°C ~ 100°C | -25°C ~ 100°C | Matched |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant | Matched |
| Approval Agencies | CSA, ENEC, UR | cURus, ENEC | Partial overlap (ENEC common) |
Engineering Selection Recommendations
The FN258HVIT-100-35 is classified as "Not For New Designs," establishing the FN3359-150-28 as the forward-compatible alternative for new implementations.
Selection between these parts depends on system voltage requirements and termination interface compatibility:
The FN258HVIT-100-35 remains suitable for applications operating within 400 V phase-to-ground and 690 V phase-to-phase specifications with terminal block connection requirements.
The FN3359-150-28 is appropriate for systems operating within 300 V phase-to-ground and 520 V phase-to-phase specifications where threaded post (M10) termination is acceptable. The higher current rating (150 A) and three-stage configuration provide margin for applications at or near the original part's 100 A specification.
Both parts maintain ROHS3 compliance and ENEC certification, supporting regulatory requirements across industrial applications.
Frequently Asked Questions (FAQ)
Q: Can FN3359-150-28 directly replace FN258HVIT-100-35 in existing designs?
A: Direct replacement requires verification of three factors: system voltage compatibility (FN3359-150-28 is rated for lower voltage), termination interface compatibility (threaded post M10 versus terminal block), and approval agency requirements for your specific application.
Q: What is the significance of the "Not For New Designs" status on FN258HVIT-100-35?
A: This designation indicates the part is obsolete for new product development. Existing inventory remains available for maintenance and legacy system support, but new designs should specify FN3359-150-28 or equivalent active-status alternatives.
Q: Why does FN3359-150-28 have lower voltage ratings despite higher current capacity?
A: Current and voltage ratings are independent design parameters. The FN3359-150-28 is engineered for different voltage class applications. System voltage requirements determine which part is appropriate, regardless of current capacity differences.
Q: Are the approval certifications equivalent between these parts?
A: Both parts carry ENEC certification. FN258HVIT-100-35 includes CSA and UR approvals, while FN3359-150-28 includes cURus approval. Verify your application's specific certification requirements before substitution.
Q: What packaging format is used for both parts?
A: Both FN258HVIT-100-35 and FN3359-150-28 are supplied in tray packaging suitable for automated assembly and inventory management.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts