FCE17E09SA640 D-Sub Receptacle Connector Equivalent & Substitute Parts

Part Overview

The FCE17E09SA640 is a 9-position D-Sub receptacle connector manufactured by Amphenol ICC (Commercial Products). This connector features female sockets, right-angle through-hole mounting, and solder termination. The part is currently active in production with 678 pieces in stock inventory.

D-Sub receptacle connectors are essential interface components in electronic systems requiring standardized signal transmission and mechanical coupling. Equivalent and substitute parts are identified when design requirements, supply chain constraints, or application specifications necessitate alternative connector options that maintain functional compatibility within defined electrical and mechanical parameters.

Substiute Parts

FCE17E09SA640
Amphenol ICC (Commercial Products)In Stock: 694FCE17E09SA640 Datasheet
FCE17E09SA640
Current Part
09681535611
HARTINGIn Stock: 127909681535611 Datasheet
09681535611
Similar
09681535612
HARTINGIn Stock: 137509681535612 Datasheet
09681535612
Similar
09681535613
HARTINGIn Stock: 122409681535613 Datasheet
09681535613
Similar
09681537611
HARTINGIn Stock: 103009681537611 Datasheet
09681537611
Similar
09681537612
HARTINGIn Stock: 85709681537612 Datasheet
09681537612
Similar
09681537613
HARTINGIn Stock: 136309681537613 Datasheet
09681537613
Similar
09681637812
HARTINGIn Stock: 117009681637812 Datasheet
09681637812
Similar
182-009-213R161
NorComp Inc.In Stock: 8747182-009-213R161 Datasheet
182-009-213R161
Similar
182-009-213R171
NorComp Inc.In Stock: 2410182-009-213R171 Datasheet
182-009-213R171
Similar
182-009-213R181
NorComp Inc.In Stock: 2008182-009-213R181 Datasheet
182-009-213R181
Similar
182-009-213R561
NorComp Inc.In Stock: 7492182-009-213R561 Datasheet
182-009-213R561
Similar
622-009-260-012
Mercury United Electronics, Inc.In Stock: 1127622-009-260-012 Datasheet
622-009-260-012
Similar
622-009-260-013
Mercury United Electronics, Inc.In Stock: 987622-009-260-013 Datasheet
622-009-260-013
Similar
622-009-260-042
Mercury United Electronics, Inc.In Stock: 1389622-009-260-042 Datasheet
622-009-260-042
Similar
622-009-260-043
Mercury United Electronics, Inc.In Stock: 1226622-009-260-043 Datasheet
622-009-260-043
Similar
622-009-560-042
Mercury United Electronics, Inc.In Stock: 751622-009-560-042 Datasheet
622-009-560-042
Similar
A-DF 09 A/KG-T2S
Assmann WSW ComponentsIn Stock: 14886A-DF 09 A/KG-T2S Datasheet
A-DF 09 A/KG-T2S
Similar
A-DF 09 A/KG-T4S
Assmann WSW ComponentsIn Stock: 34095A-DF 09 A/KG-T4S Datasheet
A-DF 09 A/KG-T4S
Similar
D09S33E4GV00LF
Amphenol ICC (FCI)In Stock: 6940D09S33E4GV00LF Datasheet
D09S33E4GV00LF
Similar
D09S33E4GX00LF
Amphenol ICC (FCI)In Stock: 3169D09S33E4GX00LF Datasheet
D09S33E4GX00LF
Similar
D09S33E6GV00LF
Amphenol ICC (FCI)In Stock: 1352D09S33E6GV00LF Datasheet
D09S33E6GV00LF
Similar
D09S33E6RV09LF
Amphenol ICC (FCI)In Stock: 764D09S33E6RV09LF Datasheet
D09S33E6RV09LF
Similar
D09S33E6RX09LF
Amphenol ICC (FCI)In Stock: 2014D09S33E6RX09LF Datasheet
D09S33E6RX09LF
Similar
ID09S33E4GV00LF
Amphenol ICC (FCI)In Stock: 3626ID09S33E4GV00LF Datasheet
ID09S33E4GV00LF
Similar
ID09S33E4GX00LF
Amphenol ICC (FCI)In Stock: 1518ID09S33E4GX00LF Datasheet
ID09S33E4GX00LF
Similar

Key Parameters

Parameter FCE17E09SA640 Specification
Connector Type Receptacle, Female Sockets
Number of Positions 9
Shell Size, Connector Layout 1 (DE, E)
Mounting Type Through Hole, Right Angle
Termination Solder
Current Rating 5A
Backset Spacing 0.318" (8.08mm)
Operating Temperature Range -40°C ~ 85°C
Material Flammability Rating UL94 V-0
RoHS Status RoHS Compliant
Moisture Sensitivity Level 1 (Unlimited)

Substitute Part Grouping Explanation

Substitute parts for the FCE17E09SA640 are identified based on the following critical parameters that determine functional compatibility:

Primary Compatibility Criteria:

  • Connector type: Receptacle, Female Sockets
  • Number of positions: 9
  • Shell size and layout: 1 (DE, E)
  • Mounting type: Through Hole, Right Angle
  • Termination method: Solder
  • Backset spacing: 0.318" (8.08mm)

Secondary Compatibility Considerations:

  • Current rating: Substitute parts must support minimum 5A
  • Material flammability rating: UL94 V-0 compliance required
  • Moisture sensitivity level: MSL 1 (Unlimited) acceptable
  • Operating temperature range: Substitute parts must encompass or exceed -40°C ~ 85°C
  • RoHS compliance status: Active product status with current regulatory compliance

Substitute parts are grouped by flange feature configuration (Housing/Shell M3, Housing/Shell 4-40, or Mating Side Female Screwlock 4-40) as these determine board-level mounting compatibility. Parts from HARTING and NorComp Inc. meet the core electrical and mechanical requirements while offering alternative design features and material compositions.

Parameter Comparison

Parameter FCE17E09SA640 (Amphenol ICC) 09681535611 (HARTING) 09681535612 (HARTING) 09681535613 (HARTING) 09681537611 (HARTING) 09681537612 (HARTING) 09681537613 (HARTING) 182-009-213R161 (NorComp) 182-009-213R171 (NorComp) 182-009-213R181 (NorComp)
Connector Type Receptacle, Female Sockets Receptacle, Female Sockets Receptacle, Female Sockets Receptacle, Female Sockets Receptacle, Female Sockets Receptacle, Female Sockets Receptacle, Female Sockets Receptacle, Female Sockets Receptacle, Female Sockets Receptacle, Female Sockets
Number of Positions 9 9 9 9 9 9 9 9 9 9
Shell Size, Connector Layout 1 (DE, E) 1 (DE, E) 1 (DE, E) 1 (DE, E) 1 (DE, E) 1 (DE, E) 1 (DE, E) 1 (DE, E) 1 (DE, E) 1 (DE, E)
Mounting Type Through Hole, Right Angle Through Hole, Right Angle Through Hole, Right Angle Through Hole, Right Angle Through Hole, Right Angle Through Hole, Right Angle Through Hole, Right Angle Panel Mount, Through Hole, Right Angle Panel Mount, Through Hole, Right Angle Panel Mount, Through Hole, Right Angle
Termination Solder Solder Solder Solder Solder Solder Solder Solder Solder Solder
Current Rating (Amps) 5A 6.5A 6.5A 6.5A 6.5A 6.5A 6.5A 5A 5A 5A
Backset Spacing 0.318" (8.08mm) 0.318" (8.08mm) 0.318" (8.08mm) 0.318" (8.08mm) 0.318" (8.08mm) 0.318" (8.08mm) 0.318" (8.08mm) 0.318" (8.08mm) 0.318" (8.08mm) 0.318" (8.08mm)
Material Flammability Rating UL94 V-0 UL94 V-0 UL94 V-0 UL94 V-0 UL94 V-0 UL94 V-0 UL94 V-0 UL94 V-0 UL94 V-0 UL94 V-0
Operating Temperature Range -40°C ~ 85°C -55°C ~ 125°C -55°C ~ 125°C -55°C ~ 125°C -55°C ~ 125°C -55°C ~ 125°C -55°C ~ 125°C -55°C ~ 105°C -55°C ~ 105°C -55°C ~ 105°C
RoHS Status RoHS Compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant
Moisture Sensitivity Level 1 (Unlimited) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited) Not Applicable Not Applicable Not Applicable
Product Status Active Active Active Active Active Active Active Active Active Active

Engineering Selection Recommendations

All substitute parts listed maintain active product status and current regulatory compliance. Selection among substitute options is determined by specific flange feature requirements and operating environment specifications.

HARTING 09681535611, 09681535612, 09681535613 Series: These parts provide higher current rating (6.5A versus 5A) and extended operating temperature range (-55°C ~ 125°C). The HARTING series offers ROHS3 compliance and REACH unaffected status. Selection within this series depends on flange configuration: 09681535611 features Housing/Shell M3, 09681535612 features Housing/Shell 4-40, and 09681535613 features Mating Side Female Screwlock 4-40.

HARTING 09681537611, 09681537612, 09681537613 Series: These parts also provide 6.5A current rating and -55°C ~ 125°C operating temperature range with ROHS3 compliance. Flange configurations match the 09681535 series. Contact finish specifications are not provided for this series.

NorComp Inc. 182-009-213R161, 182-009-213R171, 182-009-213R181 Series: These parts maintain 5A current rating matching the FCE17E09SA640 and operate across -55°C ~ 105°C. The NorComp series features panel mount capability in addition to through-hole mounting, gold contact finish with flash thickness, and ground strap features. Selection within this series depends on flange configuration: 182-009-213R161 features Housing/Shell Unthreaded, 182-009-213R171 features Housing/Shell 4-40, and 182-009-213R181 features Mating Side Female Screwlock 4-40.

All substitute parts satisfy the core electrical and mechanical requirements of the FCE17E09SA640 within their respective design parameters.

Frequently Asked Questions (FAQ)

Q: What are the primary criteria for substituting the FCE17E09SA640?

A: The FCE17E09SA640 can be substituted with alternative 9-position D-Sub receptacle connectors that maintain the following specifications: receptacle type with female sockets, shell size 1 (DE, E), through-hole right-angle mounting, solder termination, 0.318" (8.08mm) backset spacing, UL94 V-0 flammability rating, and operating temperature range encompassing -40°C to 85°C. Current rating must be minimum 5A.

Q: How do flange features affect part selection?

A: Flange features determine the mechanical mounting interface on the printed circuit board. The FCE17E09SA640 uses Housing/Shell M3 configuration. Substitute parts are available with Housing/Shell M3, Housing/Shell 4-40, or Mating Side Female Screwlock 4-40 flanges. Selection must match the board-level mounting hole pattern and fastening requirements of the target application.

Q: Are HARTING parts with higher current ratings (6.5A) compatible with 5A applications?

A: Yes. HARTING substitute parts rated for 6.5A are electrically compatible with applications designed for 5A operation. Higher current rating indicates greater capacity and does not create incompatibility with lower-current designs.

Q: What is the difference between the HARTING 09681535 and 09681537 series?

A: Both series provide identical electrical specifications (6.5A current rating, -55°C ~ 125°C operating temperature, UL94 V-0 compliance). The primary difference is contact finish specification: the 09681535 series specifies Gold or Gold-Palladium finish at 30.0µin (0.76µm) thickness, while the 09681537 series does not specify contact finish details.

Q: Do NorComp parts offer advantages over HARTING alternatives?

A: NorComp 182-009 series parts provide panel mount capability in addition to through-hole mounting, offering design flexibility for applications requiring both mounting options. NorComp parts feature gold contact finish with flash thickness and ground strap features. Operating temperature range is -55°C ~ 105°C, which is lower than HARTING but exceeds the FCE17E09SA640 specification of -40°C ~ 85°C.

Q: What is the significance of MSL (Moisture Sensitivity Level) differences?

A: The FCE17E09SA640 and HARTING substitute parts carry MSL 1 (Unlimited), indicating no moisture sensitivity restrictions during storage or handling. NorComp parts carry MSL Not Applicable, indicating these components do not require moisture-controlled storage. Both classifications are compatible for general industrial applications.

Q: Can the FCE17E09SA640 be directly replaced with a NorComp part in existing designs?

A: Direct replacement depends on flange feature compatibility. If the existing design uses Housing/Shell M3 mounting, the NorComp 182-009-213R161 provides equivalent flange configuration. If the design uses Housing/Shell 4-40 or Mating Side Female Screwlock 4-40, the corresponding NorComp part (182-009-213R171 or 182-009-213R181) must be selected. Panel mount capability of NorComp parts does not interfere with through-hole mounting applications.

Q: What packaging differences exist among substitute parts?

A: The FCE17E09SA640 is supplied in standard packaging. HARTING substitute parts are supplied in bulk packaging with inventory ranging from 767 to 1362 pieces. NorComp substitute parts are supplied in tray packaging with inventory ranging from 1991 to 8733 pieces. Packaging format does not affect electrical or mechanical compatibility.

Q: Are all substitute parts RoHS compliant?

A: Yes. The FCE17E09SA640 carries RoHS Compliant status. All HARTING substitute parts carry ROHS3 Compliant status. All NorComp substitute parts carry ROHS3 Compliant status. All parts meet current regulatory requirements for hazardous substance restrictions.

Request Quote (Ships tomorrow)