Request Quote
(Ships tomorrow)
FCC17C37SA6DB D-Sub 37 Position Receptacle Equivalent & Substitute Parts
Part Overview
The FCC17C37SA6DB is a 37 position D-Sub receptacle connector manufactured by Amphenol ICC (Commercial Products). This through-hole, right-angle solder termination connector features female sockets with a 2-row configuration in shell size 4 (DC, C). The part is classified as obsolete, necessitating identification of active equivalent and substitute components for ongoing design support and procurement continuity.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Connector Style | D-Sub |
| Connector Type | Receptacle, Female Sockets |
| Number of Positions | 37 |
| Number of Rows | 2 |
| Shell Size, Connector Layout | 4 (DC, C) |
| Mounting Type | Through Hole, Right Angle |
| Termination | Solder |
| Contact Type | Signal |
| Shell Material, Finish | Steel, Tin Plated |
| Material Flammability Rating | UL94 V-0 |
| Current Rating (Amps) | 5A |
| Voltage Rating | 200V |
| Operating Temperature | -40°C ~ 85°C |
| Product Status | Obsolete |
Substitute Part Grouping Explanation
Substitution of the FCC17C37SA6DB is determined by strict adherence to the following core parameters:
Mandatory Matching Parameters:
- Connector Style: D-Sub
- Connector Type: Receptacle, Female Sockets
- Number of Positions: 37
- Number of Rows: 2
- Shell Size, Connector Layout: 4 (DC, C)
- Mounting Type: Through Hole, Right Angle
- Termination: Solder
- Contact Type: Signal
- Material Flammability Rating: UL94 V-0
Allowable Variation Parameters:
- Current Rating: The FCC17C37SA6DB is rated at 5A. Substitute parts with higher current ratings (6.5A) are acceptable as they provide equal or superior electrical capacity.
- Backset Spacing: The FCC17C37SA6DB specifies 0.318" (8.08mm). Substitute parts with 0.409" (10.40mm) backset spacing represent a different mechanical configuration and are listed for reference but require mechanical validation.
- Contact Finish: The FCC17C37SA6DB specifies gold plating. Substitute parts without specified contact finish may have different contact material properties.
- Flange Feature: Variations in flange mounting configuration (Board Side M3, Housing/Shell M3, Housing/Shell Unthreaded, Housing/Shell 4-40) are acceptable provided the connector maintains through-hole, right-angle mounting capability.
- Dielectric Material: Variations in dielectric composition (Thermoplastic Glass Filled, Polybutylene Terephthalate, Polycyclohexylenedimethylene Terephthalate) are acceptable provided UL94 V-0 rating is maintained.
Parameter Comparison
| Parameter | FCC17C37SA6DB | FCE17C37SA6DB | 09664127600 | 09664127601 | 09664136602 | 09664526611 | 09664527610 | 09664527611 | 09664566610 | 09664566611 | 09664566612 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Manufacturer | Amphenol ICC | Amphenol ICC | HARTING | HARTING | HARTING | HARTING | HARTING | HARTING | HARTING | HARTING | HARTING |
| Connector Style | D-Sub | D-Sub | D-Sub | D-Sub | D-Sub | D-Sub | D-Sub | D-Sub | D-Sub | D-Sub | D-Sub |
| Connector Type | Receptacle, Female Sockets | Receptacle, Female Sockets | Receptacle, Female Sockets | Receptacle, Female Sockets | Receptacle, Female Sockets | Receptacle, Female Sockets | Receptacle, Female Sockets | Receptacle, Female Sockets | Receptacle, Female Sockets | Receptacle, Female Sockets | Receptacle, Female Sockets |
| Number of Positions | 37 | 37 | 37 | 37 | 37 | 37 | 37 | 37 | 37 | 37 | 37 |
| Number of Rows | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
| Shell Size, Connector Layout | 4 (DC, C) | 4 (DC, C) | 4 (DC, C) | 4 (DC, C) | 4 (DC, C) | 4 (DC, C) | 4 (DC, C) | 4 (DC, C) | 4 (DC, C) | 4 (DC, C) | 4 (DC, C) |
| Mounting Type | Through Hole, Right Angle | Through Hole, Right Angle | Through Hole, Right Angle | Through Hole, Right Angle | Through Hole, Right Angle | Through Hole, Right Angle | Through Hole, Right Angle | Through Hole, Right Angle | Through Hole, Right Angle | Through Hole, Right Angle | Through Hole, Right Angle |
| Termination | Solder | Solder | Solder | Solder | Solder | Solder | Solder | Solder | Solder | Solder | Solder |
| Contact Type | Signal | Signal | Signal | Signal | Signal | Signal | Signal | Signal | Signal | Signal | Signal |
| Material Flammability Rating | UL94 V-0 | UL94 V-0 | UL94 V-0 | UL94 V-0 | UL94 V-0 | UL94 V-0 | UL94 V-0 | UL94 V-0 | UL94 V-0 | UL94 V-0 | UL94 V-0 |
| Current Rating (Amps) | 5A | 5A | 6.5A | 6.5A | 6.5A | 6.5A | 6.5A | 6.5A | 6.5A | 6.5A | 6.5A |
| Backset Spacing | 0.318" (8.08mm) | 0.318" (8.08mm) | 0.409" (10.40mm) | 0.409" (10.40mm) | 0.409" (10.40mm) | 0.409" (10.40mm) | 0.409" (10.40mm) | 0.409" (10.40mm) | 0.409" (10.40mm) | 0.409" (10.40mm) | 0.409" (10.40mm) |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 85°C | -55°C ~ 125°C | -55°C ~ 125°C | -55°C ~ 125°C | -55°C ~ 125°C | -55°C ~ 125°C | -55°C ~ 125°C | -55°C ~ 125°C | -55°C ~ 125°C | -55°C ~ 125°C |
| Product Status | Obsolete | Active | Active | Active | Active | Active | Active | Active | Active | Obsolete | Active |
| RoHS Status | RoHS non-compliant | RoHS Compliant | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant |
Engineering Selection Recommendations
Primary Substitute: FCE17C37SA6DB (Amphenol ICC)
The FCE17C37SA6DB is the direct equivalent from the same manufacturer. It maintains identical electrical and mechanical specifications to the FCC17C37SA6DB while offering active product status and RoHS compliance. This part is the preferred substitute for direct replacement in new designs and legacy system updates.
Secondary Substitutes: HARTING 37 Position D-Sub Receptacles
The HARTING series (09664127600, 09664127601, 09664136602, 09664526611, 09664527610, 09664527611, 09664566610, 09664566611, 09664566612) provides functional equivalence with the following considerations:
All HARTING parts maintain the mandatory D-Sub receptacle configuration with 37 positions, 2 rows, shell size 4, through-hole right-angle solder termination, and UL94 V-0 flammability rating. All HARTING parts are active products with ROHS3 compliance and extended operating temperature range (-55°C ~ 125°C versus -40°C ~ 85°C).
Mechanical Variation: HARTING parts feature 0.409" (10.40mm) backset spacing compared to the FCC17C37SA6DB specification of 0.318" (8.08mm). This difference affects PCB layout and connector positioning. Selection between HARTING variants depends on flange feature requirements:
- Unthreaded Housing/Shell: 09664127600, 09664527610, 09664566610
- M3 Housing/Shell: 09664127601, 09664526611, 09664527611, 09664566611
- 4-40 Housing/Shell: 09664136602, 09664566612
Board Lock Feature: HARTING parts 09664526611, 09664527610, 09664527611, 09664566610, 09664566611, and 09664566612 include board lock functionality. Parts 09664127600, 09664127601, and 09664136602 do not include this feature.
Dielectric Material Variation: HARTING parts 09664127600, 09664127601, and 09664136602 use Polybutylene Terephthalate (PBT) dielectric. HARTING parts 09664526611, 09664527610, 09664527611 use Polybutylene Terephthalate (PBT) dielectric. HARTING parts 09664566610, 09664566611, and 09664566612 use Polycyclohexylenedimethylene Terephthalate (PCT) dielectric.
Electrical Upgrade: All HARTING substitutes provide 6.5A current rating compared to the FCC17C37SA6DB 5A rating, representing increased electrical capacity.
Frequently Asked Questions (FAQ)
Q: Can FCE17C37SA6DB directly replace FCC17C37SA6DB in existing designs?
A: Yes. The FCE17C37SA6DB maintains identical connector specifications including shell size, position count, mounting type, termination method, and electrical ratings. The primary difference is product status (active versus obsolete) and RoHS compliance status.
Q: What is the significance of the backset spacing difference between FCC17C37SA6DB (0.318") and HARTING substitutes (0.409")?
A: Backset spacing defines the distance from the mounting flange to the rear of the connector shell. The 0.409" spacing in HARTING parts requires different PCB layout and mounting hole positioning compared to the original 0.318" specification. Physical validation of PCB clearances and mounting hole alignment is necessary before implementation.
Q: Are HARTING D-Sub receptacles electrically compatible with the FCC17C37SA6DB?
A: Yes. All HARTING substitutes maintain the same D-Sub 37 position, 2-row configuration with signal contact type and UL94 V-0 flammability rating. The 6.5A current rating in HARTING parts exceeds the 5A rating of the FCC17C37SA6DB, providing equal or superior electrical capacity for signal transmission.
Q: What is the difference between HARTING parts with and without board lock features?
A: Board lock features (present in 09664526611, 09664527610, 09664527611, 09664566610, 09664566611, 09664566612) provide mechanical retention of the connector to the PCB. Parts without board lock (09664127600, 09664127601, 09664136602) rely on solder termination alone for mechanical attachment. Selection depends on application requirements for connector retention and serviceability.
Q: How do flange feature variations affect connector selection?
A: Flange features determine the mounting interface. Unthreaded housing/shell flanges provide basic mounting. M3 threaded flanges accommodate M3 fasteners for additional mechanical security. 4-40 threaded flanges accommodate 4-40 fasteners. Selection depends on the mounting structure and fastening requirements of the target application.
Q: Is the extended operating temperature range of HARTING parts (-55°C ~ 125°C) a concern for FCC17C37SA6DB replacement?
A: No. The extended temperature range in HARTING parts represents a capability enhancement. If the original application operates within -40°C ~ 85°C, HARTING parts with -55°C ~ 125°C rating provide equal performance within that range with additional margin for temperature extremes.
Q: What is the difference between Polybutylene Terephthalate (PBT) and Polycyclohexylenedimethylene Terephthalate (PCT) dielectric materials?
A: Both materials maintain UL94 V-0 flammability rating and are glass-filled thermoplastics. PCT offers enhanced thermal and chemical resistance compared to PBT. For applications within the specified operating temperature range, both materials are functionally equivalent.
Q: Can I use HARTING 09664566611 (obsolete) as a substitute for FCC17C37SA6DB?
A: The 09664566611 is classified as obsolete, similar to the FCC17C37SA6DB. While it maintains functional equivalence, active alternatives (09664566610, 09664566612) are preferred for new designs and long-term procurement continuity.
Q: What RoHS compliance status should I specify for new designs?
A: The FCC17C37SA6DB is RoHS non-compliant. For new designs, FCE17C37SA6DB (RoHS Compliant) or any HARTING substitute (ROHS3 Compliant) is recommended to meet current regulatory requirements.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts