Request Quote
(Ships tomorrow)
F56-110 Equivalent & Substitute Parts Reference
Part Overview
The F56-110 is a laminated core power transformer manufactured by Triad Magnetics, rated at 6VA with dual secondary windings. This through-hole mounted component is designed for Class 2/3 applications and is part of the Split Pack™ series. The part is currently active in production with 859 units in stock.
Equivalent and substitute parts are identified when component availability changes, supply chain disruptions occur, or design revisions require alternative sourcing while maintaining electrical and mechanical compatibility.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | F56-110 |
| Manufacturer | Triad Magnetics |
| Power Rating | 6VA |
| Primary Voltage | 115V |
| Secondary Voltage (Parallel) | 28V |
| Secondary Voltage (Series) | 56V |
| Output Current - Parallel | 220mA |
| Output Current - Series | 110mA |
| Core Type | Laminated |
| Mounting Type | Through Hole |
| Termination Style | PC Pin |
| Isolation Voltage | 2500Vrms |
| Dimensions (L x W) | 41.28mm x 33.32mm |
| Height - Seated (Max) | 33.32mm |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitution eligibility for the F56-110 is determined by strict equivalence across the following critical parameters:
Electrical Parameters (Must Match Exactly):
- Primary voltage: 115V
- Secondary voltage configuration: Parallel 28V, Series 56V
- Output current ratings: Parallel 220mA, Series 110mA
- Power rating: 6VA
- Isolation voltage: 2500Vrms
Mechanical Parameters (Must Match Exactly):
- Core type: Laminated
- Mounting type: Through Hole
- Termination style: PC Pin
- Physical dimensions: 41.28mm L x 33.32mm W x 33.32mm H (seated)
Compliance Parameters:
- RoHS3 Compliance required
- REACH Unaffected status
The substitute part 164F56 (Hammond Manufacturing) meets all electrical, mechanical, and compliance requirements and is therefore classified as a direct equivalent.
Parameter Comparison
| Parameter | F56-110 (Triad Magnetics) | 164F56 (Hammond Manufacturing) | Match Status |
|---|---|---|---|
| Power Rating | 6VA | 6VA | Equivalent |
| Primary Voltage | 115V | 115V | Equivalent |
| Secondary Voltage - Parallel | 28V | 28V | Equivalent |
| Secondary Voltage - Series | 56V | 56V | Equivalent |
| Output Current - Parallel | 220mA | 220mA | Equivalent |
| Output Current - Series | 110mA | 110mA | Equivalent |
| Core Type | Laminated | Laminated | Equivalent |
| Mounting Type | Through Hole | Through Hole | Equivalent |
| Termination Style | PC Pin | PC Pin | Equivalent |
| Isolation Voltage | 2500Vrms | 2500Vrms | Equivalent |
| Dimensions (L x W) | 41.28mm x 33.32mm | 41.28mm x 33.32mm | Equivalent |
| Height - Seated (Max) | 33.32mm | 33.32mm | Equivalent |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant | Equivalent |
| Product Status | Active | Active | Equivalent |
Engineering Selection Recommendations
Both the F56-110 and 164F56 are active production components with ROHS3 compliance and REACH Unaffected status, meeting current regulatory requirements for electronic component manufacturing and distribution.
The F56-110 (Triad Magnetics) is the primary specified part. The 164F56 (Hammond Manufacturing) is a direct electrical and mechanical equivalent suitable for applications where supply availability or procurement requirements necessitate alternative sourcing.
Selection between these parts should be based on:
- Availability and lead time requirements
- Procurement channel and supplier relationships
- Packaging format preference (Box versus Bulk)
- Cost considerations within the supply chain
Both parts satisfy identical electrical performance specifications and physical mounting requirements for through-hole PCB applications requiring 6VA laminated core transformation at 115V primary input.
Frequently Asked Questions (FAQ)
Q: Can the 164F56 be used as a direct replacement for the F56-110 in existing designs?
A: Yes. The 164F56 meets all electrical specifications (6VA, 115V primary, 28V/56V secondary, 220mA/110mA output), mechanical dimensions (41.28mm x 33.32mm x 33.32mm), mounting type (through-hole), and termination style (PC pin) of the F56-110. Both parts are ROHS3 compliant and REACH unaffected.
Q: Are there differences in packaging between these parts?
A: The F56-110 is supplied in Box packaging, while the 164F56 is supplied in Bulk packaging. This affects order quantities and handling but does not impact electrical or mechanical performance.
Q: What is the isolation voltage specification, and does it differ between parts?
A: Both the F56-110 and 164F56 provide 2500Vrms isolation voltage. This specification is identical across both parts.
Q: Are both parts suitable for Class 2/3 applications?
A: The F56-110 is specified for Class 2/3 applications as part of the Split Pack™ series. The 164F56 shares identical electrical and safety specifications, making it suitable for equivalent Class 2/3 applications.
Q: What is the weight specification for these transformers?
A: Both the F56-110 and 164F56 weigh 0.44 lb (199.58 g).
Q: Can these parts be used in parallel or series secondary configurations?
A: Yes. Both parts feature dual secondary windings that support parallel configuration (28V at 220mA) and series configuration (56V at 110mA).
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts