F520ST-GY Equivalent & Substitute Parts
Part Overview
The F520ST-GY is a 2-position disconnect terminal block connector manufactured by Eaton - Bussmann Electrical Division from the Magnum® F520 series. This component is rated for 6.3 A at 300V (both IEC and UL standards) and accommodates wire gauges from 12-24 AWG. The product is currently obsolete, making identification of compatible substitute components essential for system maintenance and component sourcing.
Substiute Parts
Key Parameters
| Parameter | F520ST-GY Value |
|---|---|
| Manufacturer | Eaton - Bussmann Electrical Division |
| Series | Magnum® F520 |
| Type | Disconnect |
| Number of Positions | 2 |
| Number of Levels | 1 |
| Disconnect Type | Fuse, Lever |
| Terminal Width | 8.0 mm |
| Termination Style | Screw |
| Current Rating (IEC/UL) | 6.3 A |
| Voltage Rating (IEC) | 300V |
| Voltage Rating (UL) | 300V |
| Wire Gauge Range (AWG) | 12-24 AWG |
| Wire Gauge Range (mm²) | 0.5-4 mm² |
| Fuse Type | 5mm x 20mm |
| Insulation Material | Polyamide (PA66), Nylon 6/6 |
| Flammability Rating | UL94 V-0 |
| Stripping Length | 10 mm |
| Color | Gray |
| Product Status | Obsolete |
Substitute Part Grouping Explanation
Substitution eligibility for the F520ST-GY is determined by the following critical parameters:
- Electrical Compatibility: Current rating of 6.3 A (IEC and UL), voltage rating minimum 300V (IEC) and 300V (UL)
- Physical Compatibility: 2-position, 1-level configuration with 8.0 mm terminal width and screw termination
- Wire Accommodation: Support for wire gauges within or overlapping the 12-24 AWG range
- Functional Compatibility: Disconnect type with fuse and lever mechanism, 5mm x 20mm fuse accommodation
- Material Compliance: Polyamide (PA66) insulation with UL94 V-0 flammability rating
The substitute part 41078.2 meets these criteria with the following considerations: it maintains the same current rating (6.3 A), exceeds the minimum voltage requirement at 400V (IEC), supports a compatible wire gauge range (12-22 AWG), and uses identical insulation material and fuse type specifications.
Parameter Comparison
| Parameter | F520ST-GY | 41078.2 | Compatibility Notes |
|---|---|---|---|
| Manufacturer | Eaton - Bussmann | On Shore Technology Inc. | Different manufacturers |
| Type | Disconnect | Disconnect | Identical |
| Number of Positions | 2 | 2 | Identical |
| Number of Levels | 1 | 1 | Identical |
| Disconnect Type | Fuse, Lever | Fuse, Lever | Identical |
| Terminal Width | 8.0 mm | 8.0 mm | Identical |
| Termination Style | Screw | Screw | Identical |
| Current Rating (IEC/UL) | 6.3 A | 6.3 A | Identical |
| Voltage Rating (IEC) | 300V | 400V | 41078.2 exceeds requirement |
| Voltage Rating (UL) | 300V | 300V | Identical |
| Wire Gauge Range (AWG) | 12-24 AWG | 12-22 AWG | 41078.2 range is subset; 24 AWG not supported |
| Wire Gauge Range (mm²) | 0.5-4 mm² | 0.2-4 mm² | 41078.2 supports lower range |
| Fuse Type | 5mm x 20mm | 5mm x 20mm | Identical |
| Insulation Material | Polyamide (PA66), Nylon 6/6 | Polyamide (PA66), Nylon 6/6 | Identical |
| Flammability Rating | UL94 V-0 | Not specified | F520ST-GY specifies UL94 V-0 |
| Stripping Length | 10 mm | 9 mm | Minor difference; 41078.2 requires 1 mm less |
| Product Status | Obsolete | Active | 41078.2 is currently available |
Engineering Selection Recommendations
The 41078.2 from On Shore Technology Inc. is functionally compatible with the F520ST-GY for applications requiring 2-position disconnect terminal blocks with 6.3 A current rating and 300V minimum voltage operation.
Compatibility Assessment:
The 41078.2 maintains electrical equivalence across current and voltage ratings. The wire gauge range difference (12-22 AWG versus 12-24 AWG) represents a practical limitation: applications using 24 AWG wire cannot use the 41078.2 substitute. The stripping length variance (9 mm versus 10 mm) is a minor mechanical difference that does not affect functional compatibility.
Compliance Considerations:
The F520ST-GY specifies UL94 V-0 flammability rating; the 41078.2 does not provide this specification in the available data. The 41078.2 is ROHS3 compliant and REACH unaffected, whereas the F520ST-GY provides only ECCN and HTSUS classifications. For applications with specific flammability or environmental compliance requirements, these differences must be evaluated against system specifications.
Product Status:
The F520ST-GY is obsolete; the 41078.2 is active production. Component availability and long-term supply chain considerations favor the 41078.2 for new designs or ongoing maintenance sourcing.
Frequently Asked Questions (FAQ)
Q: Can the 41078.2 directly replace the F520ST-GY in all applications?
A: The 41078.2 is compatible for applications using wire gauges 12-22 AWG. If your application requires 24 AWG wire accommodation, the 41078.2 cannot be used as a direct substitute. All other electrical and mechanical parameters are compatible.
Q: What is the significance of the stripping length difference (10 mm vs. 9 mm)?
A: Stripping length defines the amount of insulation that must be removed from the wire before termination. The 41078.2 requires 1 mm less stripped length than the F520ST-GY. This is a minor mechanical difference that does not affect electrical performance if proper termination procedures are followed.
Q: Does the 41078.2 meet the same flammability standards as the F520ST-GY?
A: The F520ST-GY specifies UL94 V-0 flammability rating. The 41078.2 does not provide flammability rating data in the available specifications. For applications with specific flammability requirements, contact the manufacturer to confirm compliance.
Q: Why does the 41078.2 have a higher IEC voltage rating (400V vs. 300V)?
A: The 41078.2 is rated for 400V at IEC standards, which exceeds the F520ST-GY requirement of 300V. This higher rating does not create incompatibility; it indicates the 41078.2 can operate safely in applications up to 400V IEC, making it suitable for F520ST-GY replacement in 300V systems.
Q: Is the 41078.2 available in the same gray color as the F520ST-GY?
A: The 41078.2 is available in beige color, not gray. If color matching is a system requirement, this difference must be considered.
Q: What is the current availability status of these components?
A: The F520ST-GY is obsolete with 876 pieces in current inventory. The 41078.2 is active production with 1022 pieces in current inventory, making it the recommended choice for ongoing sourcing.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts