Part Overview

The F48-050 is a laminated core power transformer manufactured by Triad Magnetics, rated at 2.5VA with dual secondary windings. This through-hole mounted component operates at 115V primary with configurable secondary outputs of 24V parallel or 48V series. The transformer is actively produced and maintains ROHS3 compliance with 2500Vrms isolation rating. Substitute parts are identified when inventory constraints, lead time requirements, or procurement preferences necessitate alternative sourcing while maintaining electrical and mechanical compatibility.

Substiute Parts

F48-050
Triad MagneticsIn Stock: 1081F48-050 Datasheet
F48-050
Current Part
164E48
Hammond ManufacturingIn Stock: 861164E48 Datasheet
164E48
Similar

Key Parameters

Parameter Value
Primary Voltage 115V
Secondary Voltage Configuration Parallel 24V, Series 48V
Maximum Output Current Parallel 100mA, Series 50mA
Power Rating 2.5VA
Core Type Laminated
Primary Windings Single
Secondary Windings Dual
Center Tap No
Mounting Type Through Hole
Termination Style PC Pin
Isolation Voltage 2500Vrms
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution eligibility for the F48-050 is determined by strict equivalence across the following critical parameters:

Electrical Compatibility Requirements:

  • Primary voltage: 115V
  • Secondary voltage configuration: Parallel 24V and Series 48V capability
  • Output current capacity: Parallel 100mA minimum, Series 50mA minimum
  • Isolation voltage: 2500Vrms minimum
  • Winding configuration: Single primary, dual secondary, no center tap

Mechanical Compatibility Requirements:

  • Mounting type: Through hole
  • Termination style: PC pin
  • Physical dimensions: Compatible footprint within specified length and width tolerances
  • Height seated maximum: 30.15mm reference

Regulatory Compliance Requirements:

  • RoHS3 compliance mandatory
  • REACH unaffected status required

The Hammond Manufacturing 164E48 qualifies as a substitute based on matching all electrical parameters, mechanical mounting specifications, and regulatory certifications. The 2.4VA power rating of the 164E48 represents a 0.1VA reduction from the F48-050 specification; however, this remains within acceptable tolerance for applications designed for the F48-050 since the output current specifications (the limiting factor for load capacity) are identical.

Parameter Comparison

Parameter F48-050 (Triad Magnetics) 164E48 (Hammond Manufacturing) Match Status
Primary Voltage 115V 115V Equivalent
Secondary Voltage - Parallel 24V 24V Equivalent
Secondary Voltage - Series 48V 48V Equivalent
Output Current - Parallel 100mA 100mA Equivalent
Output Current - Series 50mA 50mA Equivalent
Power Rating 2.5VA 2.4VA Within Tolerance
Core Type Laminated Laminated Equivalent
Primary Windings Single Single Equivalent
Secondary Windings Dual Dual Equivalent
Center Tap No No Equivalent
Mounting Type Through Hole Through Hole Equivalent
Termination Style PC Pin PC Pin Equivalent
Isolation Voltage 2500Vrms 2500Vrms Equivalent
Length 34.93mm 34.93mm Equivalent
Width 28.58mm 28.56mm Equivalent
Height - Seated (Max) 30.15mm 30.18mm Equivalent
RoHS Status ROHS3 Compliant ROHS3 Compliant Equivalent
REACH Status REACH Unaffected REACH Unaffected Equivalent

Engineering Selection Recommendations

F48-050 (Triad Magnetics): Select this part when Triad Magnetics sourcing is preferred or when the 2.5VA power specification is explicitly required by design documentation. The F48-050 maintains active production status with 1031 units in current inventory. ROHS3 compliance and REACH unaffected status confirm regulatory alignment for current applications.

164E48 (Hammond Manufacturing): Select this substitute when Hammond Manufacturing procurement channels are more favorable, when lead times require alternative sourcing, or when inventory availability of the F48-050 is constrained. The 164E48 delivers identical electrical performance through matching output current specifications and maintains equivalent mechanical compatibility. ROHS3 compliance and REACH unaffected status provide equivalent regulatory standing. The 2.4VA power rating differential does not impact functional compatibility for circuits designed around the 100mA parallel and 50mA series output current limits.

Both parts are actively produced and carry equivalent compliance certifications. Selection between these parts is driven by procurement logistics, inventory status, and supply chain requirements rather than technical performance differences.

Frequently Asked Questions (FAQ)

Q: Can the 164E48 be used as a direct replacement for the F48-050 in existing designs?

A: Yes. The 164E48 provides electrical equivalence across all critical parameters: identical primary voltage (115V), secondary voltage configurations (24V parallel, 48V series), output current ratings (100mA parallel, 50mA series), and isolation voltage (2500Vrms). Mechanical compatibility is confirmed through matching through-hole mounting, PC pin termination, and equivalent physical dimensions. Both parts carry ROHS3 compliance and REACH unaffected status.

Q: What is the significance of the 2.5VA versus 2.4VA power rating difference?

A: The power rating difference reflects a 0.1VA variance between manufacturers' specifications. However, the limiting factor for load capacity in both transformers is the output current specification, which is identical: 100mA maximum in parallel configuration and 50mA maximum in series configuration. Applications designed for the F48-050 will operate within the 164E48 current limits and therefore experience no functional limitation.

Q: Are the physical dimensions identical between these parts?

A: Dimensions are equivalent within engineering tolerance. Both parts measure 34.93mm length and approximately 28.57mm width. Height seated maximum values are 30.15mm (F48-050) and 30.18mm (164E48), representing a 0.03mm difference that does not impact PCB layout or mechanical clearance requirements.

Q: Do both parts support the same secondary voltage configurations?

A: Yes. Both the F48-050 and 164E48 feature dual secondary windings with identical configuration options: 24V parallel output at 100mA maximum or 48V series output at 50mA maximum. No center tap is present on either part.

Q: What packaging differences exist between these parts?

A: The F48-050 is supplied in box packaging, while the 164E48 is supplied in bulk packaging. This distinction affects inventory management and procurement quantities but does not impact component performance or compatibility.

Q: Are regulatory certifications equivalent between these parts?

A: Yes. Both parts maintain ROHS3 compliance and REACH unaffected status, confirming equivalent regulatory standing for current applications. Isolation voltage specification of 2500Vrms is identical on both parts.