Request Quote
(Ships tomorrow)
F03P006S05D Current Sensor Equivalent & Substitute Parts
Part Overview
The F03P006S05D is an active current sensor manufactured by Tamura, designed for AC current measurement applications. This flux gate, closed-loop bidirectional module operates with a 6A sensing range and delivers ratiometric voltage output. The part is currently in active production status with 927 units available in new original stock.
Identifying equivalent and substitute parts is necessary when the primary part number becomes unavailable, when alternative packaging formats are required for manufacturing processes, or when inventory constraints necessitate sourcing from alternative stock locations while maintaining identical electrical and mechanical performance.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | F03P006S05D |
| Manufacturer | Tamura |
| Series | F03P |
| Sensor Type | Flux Gate, Closed Loop |
| Current - Sensing | 6A |
| Number of Channels | 1 |
| Output Type | Ratiometric, Voltage |
| Sensitivity | 104.2mV/A |
| Frequency | 300kHz |
| Linearity | ±0.1% |
| Voltage - Supply | 4.75V ~ 5.25V |
| Response Time | 0.3µs |
| Current - Supply (Max) | 25mA |
| Operating Temperature | -40°C ~ 105°C |
| Polarization | Bidirectional |
| Mounting Type | Through Hole |
| Package / Case | Module |
| Product Status | Active |
| RoHS Status | RoHS Compliant |
Substitute Part Grouping Explanation
Substitution eligibility for the F03P006S05D is determined by strict equivalence across all critical electrical and mechanical parameters. The substitute part F03P006S05L maintains identical performance specifications across the following key criteria:
Electrical Parameters (Must Match):
- Current sensing range: 6A
- Output configuration: Ratiometric, Voltage
- Sensitivity: 104.2mV/A
- Frequency response: 300kHz
- Linearity: ±0.1%
- Supply voltage range: 4.75V ~ 5.25V
- Response time: 0.3µs
- Maximum supply current: 25mA
- Operating temperature range: -40°C ~ 105°C
- Polarization: Bidirectional
Mechanical Parameters (Must Match):
- Mounting type: Through Hole
- Package type: Module
- Single channel configuration
Differentiating Factor: The F03P006S05L differs from the F03P006S05D only in packaging format (Tray versus standard packaging) and RoHS certification version (ROHS3 Compliant versus RoHS Compliant). These differences do not affect electrical performance or functional compatibility in circuit applications.
Parameter Comparison
| Parameter | F03P006S05D | F03P006S05L | Match Status |
|---|---|---|---|
| Manufacturer | Tamura | Tamura | Identical |
| Series | F03P | F03P | Identical |
| Sensor Type | Flux Gate, Closed Loop | Flux Gate, Closed Loop | Identical |
| Current - Sensing | 6A | 6A | Identical |
| Number of Channels | 1 | 1 | Identical |
| Output Type | Ratiometric, Voltage | Ratiometric, Voltage | Identical |
| Sensitivity | 104.2mV/A | 104.2mV/A | Identical |
| Frequency | 300kHz | 300kHz | Identical |
| Linearity | ±0.1% | ±0.1% | Identical |
| Voltage - Supply | 4.75V ~ 5.25V | 4.75V ~ 5.25V | Identical |
| Response Time | 0.3µs | 0.3µs | Identical |
| Current - Supply (Max) | 25mA | 25mA | Identical |
| Operating Temperature | -40°C ~ 105°C | -40°C ~ 105°C | Identical |
| Polarization | Bidirectional | Bidirectional | Identical |
| Mounting Type | Through Hole | Through Hole | Identical |
| Package / Case | Module | Module | Identical |
| Packaging Format | Standard | Tray | Different |
| RoHS Status | RoHS Compliant | ROHS3 Compliant | Different Version |
| Product Status | Active | Active | Identical |
Engineering Selection Recommendations
Primary Part (F03P006S05D): The F03P006S05D is the standard configuration for this current sensor module. It carries RoHS Compliance certification and is actively manufactured by Tamura with 927 units in current stock. This part number is suitable for applications requiring standard packaging formats and conventional RoHS compliance documentation.
Substitute Part (F03P006S05L): The F03P006S05L is a direct functional equivalent with identical electrical and mechanical specifications. It differs only in packaging format (Tray) and RoHS certification version (ROHS3 Compliant). This part is actively manufactured with higher inventory availability (1310 units in stock). Selection of F03P006S05L is appropriate when:
- Tray packaging format is compatible with manufacturing assembly processes
- ROHS3 Compliance certification meets regulatory requirements
- Higher inventory availability is advantageous for supply chain continuity
Both parts are active products from the same manufacturer within the same series, ensuring long-term availability and consistent performance characteristics.
Frequently Asked Questions (FAQ)
Q: Can F03P006S05L be used as a direct replacement for F03P006S05D in existing circuit designs?
A: Yes. The F03P006S05L is electrically and mechanically identical to the F03P006S05D. All electrical parameters, including current sensing range, output voltage characteristics, frequency response, linearity, supply voltage requirements, response time, and operating temperature range are identical. The through-hole mounting configuration is unchanged. No circuit modifications are required.
Q: What is the difference between the two part numbers?
A: The F03P006S05D and F03P006S05L differ in two aspects: packaging format (standard versus Tray) and RoHS certification version (RoHS Compliant versus ROHS3 Compliant). These differences do not affect electrical performance or functional operation in circuit applications.
Q: Does the packaging format difference affect circuit performance?
A: No. Packaging format (standard versus Tray) is a logistics and manufacturing consideration only. It does not affect the electrical characteristics, performance specifications, or functional behavior of the sensor module itself.
Q: Are both parts currently available?
A: Yes. Both F03P006S05D and F03P006S05L are active products in current production. F03P006S05D has 927 units in stock, while F03P006S05L has 1310 units in stock.
Q: Which RoHS certification version should I select?
A: Selection between RoHS Compliant and ROHS3 Compliant depends on your specific regulatory and customer requirements. Both certifications are valid environmental compliance standards. Verify your application's compliance documentation requirements before final part selection.
Q: Can I mix F03P006S05D and F03P006S05L units in the same production batch?
A: Yes. Since both parts are electrically and mechanically identical, they can be used interchangeably within the same design and production batch without affecting circuit performance or reliability.
Q: What is the 6A current sensing specification?
A: The 6A specification indicates the maximum AC current measurement range for this flux gate, closed-loop sensor module. The sensor delivers a ratiometric voltage output with 104.2mV/A sensitivity across this range.
Q: Is the 300kHz frequency specification a bandwidth limitation?
A: The 300kHz frequency specification indicates the operating frequency of the flux gate sensor's internal oscillator. This supports the closed-loop measurement architecture and enables the 0.3µs response time characteristic.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts