F01P006S05 Current Sensor Flux Gate Equivalent & Substitute Parts

Part Overview

The F01P006S05 is a closed-loop bidirectional flux gate current sensor manufactured by Tamura, designed for AC current measurement applications up to 6A. This component operates as a 1-channel ratiometric voltage output module with high sensitivity and fast response characteristics. The F01P006S05 is classified as obsolete product status, making identification of compatible substitute parts essential for ongoing system support and new design implementations. The primary substitute maintains functional equivalence while offering active product status and extended measurement capability.

Substiute Parts

F01P006S05
TamuraIn Stock: 838F01P006S05 Datasheet
F01P006S05
Current Part
F01P006S05L
TamuraIn Stock: 992F01P006S05L Datasheet
F01P006S05L
MFR Recommended

Key Parameters

Parameter Value
Manufacturer Part Number F01P006S05
Manufacturer Tamura
Series F01P
Sensor Type Flux Gate, Closed Loop
Current Sensing Range 6A
Number of Channels 1
Output Type Ratiometric, Voltage
Sensitivity 104.2 mV/A
Supply Voltage 5V
Accuracy ±2.5%
Linearity ±1%
Operating Temperature Range -40°C to +105°C
Mounting Type Through Hole
Package Type Module
Polarization Bidirectional
Product Status Obsolete
RoHS Compliance RoHS Compliant

Substitute Part Grouping Explanation

Substitution eligibility for the F01P006S05 is determined by strict equivalence across the following critical parameters:

Electrical Equivalence Criteria:

  • Sensor type classification: Flux Gate, Closed Loop topology
  • Current sensing capacity: 6A maximum
  • Output configuration: Ratiometric voltage output
  • Sensitivity specification: 104.2 mV/A
  • Supply voltage requirement: 5V
  • Accuracy tolerance: ±2.5%
  • Linearity tolerance: ±1%
  • Response time: 0.3 µs
  • Maximum supply current: 25 mA
  • Frequency specification: 300 kHz

Mechanical Equivalence Criteria:

  • Mounting configuration: Through Hole
  • Package classification: Module
  • Operating temperature range: -40°C to +105°C
  • Polarization type: Bidirectional

Compliance Criteria:

  • RoHS compliance status
  • ECCN classification: EAR99
  • HTSUS code: 9030.33.3800

The F01P006S05L qualifies as a direct substitute based on complete parameter alignment across all electrical, mechanical, and compliance specifications.

Parameter Comparison

Parameter F01P006S05 (Main Part) F01P006S05L (Substitute) Equivalence Status
Manufacturer Tamura Tamura Identical
Series F01P F01P Identical
Sensor Type Flux Gate, Closed Loop Flux Gate, Closed Loop Identical
Current Sensing 6A 6A Identical
Number of Channels 1 1 Identical
Output Type Ratiometric, Voltage Ratiometric, Voltage Identical
Sensitivity 104.2 mV/A 104.2 mV/A Identical
Frequency 300 kHz 300 kHz Identical
Linearity ±1% ±1% Identical
Accuracy ±2.5% ±2.5% Identical
Supply Voltage 5V 5V Identical
Response Time 0.3 µs 0.3 µs Identical
Supply Current (Max) 25 mA 25 mA Identical
Operating Temperature -40°C to +105°C -40°C to +105°C Identical
Polarization Bidirectional Bidirectional Identical
Mounting Type Through Hole Through Hole Identical
Package Type Module Module Identical
RoHS Status RoHS Compliant RoHS Compliant Identical
Product Status Obsolete Active Substitute is Active
Measurement Capability AC AC/DC Substitute has Extended Range

Engineering Selection Recommendations

Primary Substitute: F01P006S05L

The F01P006S05L is the manufacturer-recommended substitute for the obsolete F01P006S05. This part maintains complete electrical and mechanical equivalence across all specified parameters, ensuring direct functional compatibility in existing circuit designs.

Advantages of F01P006S05L:

  • Active product status ensures long-term availability and supply chain continuity
  • Identical electrical specifications guarantee drop-in replacement capability
  • Extended measurement capability (AC/DC) provides additional application flexibility beyond the original AC-only specification
  • RoHS compliance maintained for regulatory alignment
  • Same through-hole mounting configuration and module package type

Selection Basis: The substitution is based on manufacturer designation, product status transition from obsolete to active, and complete parameter equivalence. The F01P006S05L represents the current production equivalent within the Tamura F01P series flux gate current sensor family.

Frequently Asked Questions (FAQ)

Q: Can the F01P006S05L be used as a direct replacement for F01P006S05 in existing designs?

A: Yes. The F01P006S05L is electrically and mechanically equivalent to the F01P006S05 across all specified parameters. No circuit modifications are required for substitution. The parts are pin-compatible and functionally interchangeable.

Q: What is the difference between F01P006S05 and F01P006S05L?

A: The primary differences are product status and measurement capability. The F01P006S05 is obsolete and measures AC current only. The F01P006S05L is active production and measures both AC and DC current. All other electrical specifications, including sensitivity, accuracy, linearity, and response time, are identical.

Q: Are there any package or mounting differences between these parts?

A: No. Both parts use identical through-hole mounting configuration and module package type. Physical dimensions and pin assignments are equivalent, allowing direct PCB compatibility.

Q: What is the sensitivity specification for both parts?

A: Both the F01P006S05 and F01P006S05L have a sensitivity of 104.2 mV/A, providing identical output voltage scaling for current measurement applications.

Q: Do both parts require the same 5V supply voltage?

A: Yes. Both parts operate from a 5V supply voltage with maximum supply current of 25 mA. Power supply requirements are identical.

Q: What is the operating temperature range for these sensors?

A: Both parts operate across the temperature range of -40°C to +105°C, providing equivalent thermal performance for industrial and extended-temperature applications.

Q: Are both parts RoHS compliant?

A: Yes. Both the F01P006S05 and F01P006S05L are RoHS compliant, meeting environmental and regulatory requirements for electronic component manufacturing.

Q: Why is the F01P006S05 listed as obsolete?

A: The F01P006S05 has been discontinued by the manufacturer. The F01P006S05L represents the current production equivalent and is recommended for all new designs and ongoing system support.

Q: Can the F01P006S05L measure DC current in addition to AC?

A: Yes. The F01P006S05L supports both AC and DC current measurement, extending application capability beyond the original F01P006S05 AC-only specification.

Q: What is the response time for current measurement?

A: Both parts have a response time of 0.3 µs, providing fast transient response for dynamic current measurement applications.

Q: Are the accuracy and linearity specifications the same?

A: Yes. Both parts maintain ±2.5% accuracy and ±1% linearity specifications, ensuring equivalent measurement precision and signal fidelity.