ES01FV0 Equivalent & Substitute Parts Reference

Part Overview

The ES01FV0, manufactured by Sanken Electric USA Inc., is an axial, through-hole diode in the Diodes, Rectifiers category. This device is defined by its general-purpose rectification functionality, supporting a maximum DC reverse voltage of 1500 V and an average rectified current of 500 mA. With an active product status and RoHS compliance, it is suitable for environments where these attributes are mandatory. Identifying suitable alternative models is necessary in inventory risk scenarios, demand surges, and supply chain optimization for production continuity.

Substiute Parts

ES01FV0
Sanken Electric USA Inc.In Stock: 955ES01FV0 Datasheet
ES01FV0
Current Part
ES 1FV1
Sanken Electric USA Inc.In Stock: 1249ES 1FV1 Datasheet
ES 1FV1
Parametric Equivalent
ES01FV1
Sanken Electric USA Inc.In Stock: 1131ES01FV1 Datasheet
ES01FV1
Parametric Equivalent

Key Parameters

Parameter Value
Voltage - DC Reverse (Vr) (Max) 1500 V
Current - Average Rectified (Io) 500 mA
Voltage - Forward (Vf) (Max) @ If 2 V @ 500 mA
Speed Standard Recovery >500ns, > 200mA (Io)
Reverse Recovery Time (trr) 1.5 µs
Current - Reverse Leakage @ Vr 10 µA @ 1500 V
Mounting Type Through Hole
Package / Case Axial
Operating Temperature - Junction -40°C ~ 150°C
RoHS Status RoHS Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)

Substitute Part Grouping Explanation

Substitute parts for ES01FV0 are strictly grouped based on identical electrical, mechanical, and compliance parameters. The critical parameters for substitution verification are: Voltage - DC Reverse (Vr) (Max), Current - Average Rectified (Io), Voltage - Forward (Vf) (Max) @ If, Speed, Reverse Recovery Time (trr), Current - Reverse Leakage @ Vr, Mounting Type, Package / Case, Operating Temperature - Junction, RoHS Status, and Moisture Sensitivity Level (MSL). Only parts matching exactly on these key specifications qualify as substitutes within the Diodes, Rectifiers category.

Parameter Comparison

Manufacturer Part Number Voltage - DC Reverse (Vr) (Max) Current - Average Rectified (Io) Voltage - Forward (Vf) (Max) @ If Speed Reverse Recovery Time (trr) Current - Reverse Leakage @ Vr Mounting Type Package / Case Operating Temperature - Junction RoHS Status Moisture Sensitivity Level (MSL) Product Status
ES01FV0 1500 V 500 mA 2 V @ 500 mA Standard Recovery >500ns, > 200mA (Io) 1.5 µs 10 µA @ 1500 V Through Hole Axial -40°C ~ 150°C RoHS Compliant 1 (Unlimited) Active
ES 1FV1 1500 V 500 mA 2 V @ 500 mA Standard Recovery >500ns, > 200mA (Io) 1.5 µs 10 µA @ 1500 V Through Hole Axial -40°C ~ 150°C ROHS3 Compliant 1 (Unlimited) Active
ES01FV1 1500 V 500 mA 2 V @ 500 mA Standard Recovery >500ns, > 200mA (Io) 1.5 µs 10 µA @ 1500 V Through Hole Axial -40°C ~ 150°C RoHS Compliant 1 (Unlimited) Active

Engineering Selection Recommendations

All substitute parts listed have an active product status and conform to required compliance standards, including RoHS or ROHS3. Moisture Sensitivity Level (MSL 1) is identical, ensuring unlimited floor life under typical manufacturing conditions. Selection between ES01FV0, ES 1FV1, and ES01FV1 is technically validated by these attributes. No differences exist in electrical or mechanical compatibility within the provided parameters for Diodes, Rectifiers in axial, through-hole configuration.

Frequently Asked Questions (FAQ)

Q1: What parameters must match for diode rectifier substitution?
Substitution requires identical values for maximum DC reverse voltage, average rectified current, forward voltage at test current, reverse recovery time, reverse leakage current, mounting type, package/case, operating temperature range, RoHS compliance, and moisture sensitivity level.

Q2: Are all listed substitutes compatible in a through-hole, axial configuration?
All substitutes are specified as through-hole, axial diodes within the same category, ensuring physical and electrical drop-in compatibility.

Q3: Does the difference between RoHS and ROHS3 affect substitution?
Both RoHS and ROHS3 indicate compliance with environmental standards. For most requirements, either is acceptable if electrical and mechanical parameters match.

Q4: Is there any impact from packaging type (Tape & Box or Cut Tape) on selection?
Packaging impacts inventory handling but does not affect diode electrical or mechanical suitability. Selection may align with manufacturing or supply chain preferences only.

Q5: Will using ES 1FV1 or ES01FV1 maintain identical operating temperature and reliability?
Operating temperature range and key reliability parameters, including reverse leakage and recovery time, are explicitly matched, ensuring consistent performance.

Q6: Can I interchange all listed substitute part numbers for ES01FV0 in PCB design?
All listed part numbers conform to axial, through-hole specifications, supporting direct interchangeability in printed circuit board designs where ES01FV0 footprint is employed.

Request Quote (Ships tomorrow)