ELC-09D120DF Equivalent & Substitute Parts

Part Overview

The ELC-09D120DF is a 12 µH unshielded wirewound inductor manufactured by Panasonic Electronic Components, rated for 2.3 A with a DC resistance of 31mOhm. This component is classified as obsolete, making equivalent substitute parts necessary for new designs, repairs, and production continuity. The part is mounted through-hole in a radial, vertical cylinder package and complies with ROHS3 standards.

Substiute Parts

ELC-09D120DF
Panasonic Electronic ComponentsIn Stock: 874ELC-09D120DF Datasheet
ELC-09D120DF
Current Part
RL622-120K-RC
Bourns Inc.In Stock: 1878RL622-120K-RC Datasheet
RL622-120K-RC
Similar

Key Parameters

Parameter Value
Inductance 12 µH
Current Rating 2.3 A
DC Resistance (DCR) 31mOhm
Tolerance ±20%
Shielding Unshielded
Mounting Type Through Hole
Package / Case Radial, Vertical Cylinder
Size / Dimension 0.374" Dia (9.50mm)
Height - Seated (Max) 0.350" (8.90mm)
RoHS Status ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution of the ELC-09D120DF is determined by the following critical parameters:

  • Inductance Value: Must be 12 µH to maintain circuit functionality
  • Current Rating: Substitute must support minimum 2.3 A; higher ratings are acceptable
  • DC Resistance (DCR): Substitute DCR must not significantly exceed the original 31mOhm to prevent excessive power dissipation
  • Mounting Type: Must be through-hole to ensure PCB compatibility
  • Package / Case: Must be radial, vertical cylinder configuration for mechanical fit
  • Shielding: Unshielded configuration is maintained across substitutes
  • Compliance: ROHS3 compliance is required for regulatory alignment

The RL622-120K-RC from Bourns Inc. meets these substitution criteria with equivalent inductance, superior current rating (2.7 A vs. 2.3 A), and compatible through-hole radial mounting. While the DCR is higher at 50mOhm maximum, this remains within acceptable engineering tolerances for most applications requiring this inductance value.

Parameter Comparison

Parameter ELC-09D120DF (Panasonic) RL622-120K-RC (Bourns)
Inductance 12 µH 12 µH
Tolerance ±20% ±10%
Current Rating (Amps) 2.3 A 2.7 A
DC Resistance (DCR) 31mOhm 50mOhm Max
Shielding Unshielded Unshielded
Mounting Type Through Hole Through Hole
Package / Case Radial, Vertical Cylinder Radial, Vertical Cylinder
Size / Dimension 0.374" Dia (9.50mm) 0.335" Dia (8.50mm)
Height - Seated (Max) 0.350" (8.90mm) 0.433" (11.00mm)
RoHS Status ROHS3 Compliant ROHS3 Compliant
Product Status Obsolete Active

Engineering Selection Recommendations

The RL622-120K-RC is the primary substitute for the ELC-09D120DF based on the following factors:

  • Product Status: The RL622-120K-RC is active and in production, ensuring long-term availability and supply chain continuity
  • Compliance: Both parts are ROHS3 compliant, maintaining regulatory requirements
  • Electrical Performance: The substitute provides equivalent inductance at 12 µH with improved current rating (2.7 A vs. 2.3 A), offering design margin
  • Mechanical Compatibility: Both parts use through-hole radial, vertical cylinder mounting; however, dimensional differences exist (diameter and height variations)
  • Certifications: Both parts carry ECCN EAR99 classification

Selection of the RL622-120K-RC is appropriate for applications where the ELC-09D120DF is no longer available. PCB layout verification is necessary due to dimensional differences in diameter and height.

Frequently Asked Questions (FAQ)

Q: Can the RL622-120K-RC directly replace the ELC-09D120DF without circuit modification?

A: The RL622-120K-RC provides equivalent inductance (12 µH) and superior current rating (2.7 A vs. 2.3 A). However, the higher DCR (50mOhm max vs. 31mOhm) may increase power dissipation in high-current applications. Circuit performance should be verified for applications sensitive to DCR variations.

Q: Are there mechanical fit concerns when substituting these parts?

A: Yes. The RL622-120K-RC has a smaller diameter (0.335" vs. 0.374") but greater height (0.433" vs. 0.350"). PCB layout and component placement must be verified to ensure the substitute fits within available space constraints.

Q: Do both parts meet the same compliance standards?

A: Both the ELC-09D120DF and RL622-120K-RC are ROHS3 compliant and carry ECCN EAR99 classification. Compliance requirements are maintained across the substitution.

Q: What is the tolerance difference between these parts?

A: The ELC-09D120DF has ±20% tolerance, while the RL622-120K-RC has ±10% tolerance. The substitute offers tighter inductance tolerance, which may improve circuit performance in applications requiring precise inductance values.

Q: Is the RL622-120K-RC suitable for all applications using the ELC-09D120DF?

A: The substitute is suitable for applications where the 12 µH inductance value and through-hole radial mounting are required. Applications with strict DCR or dimensional constraints must be evaluated individually based on circuit requirements and available PCB space.

Request Quote (Ships tomorrow)