EE2-12NUX Equivalent & Substitute Parts

Part Overview

The EE2-12NUX is a general purpose relay manufactured by KEMET, classified as a DPDT (2 Form C) surface mount component with a 12VDC coil voltage and 2A contact rating. This relay is designed for applications requiring dual-pole, dual-throw switching functionality with non-latching operation. The part maintains Active product status with full RoHS3 compliance and REACH unaffected designation.

Substitute parts are identified when equivalent electrical and mechanical parameters are maintained across the same product series, ensuring functional interchangeability within specified operating conditions.

Substiute Parts

EE2-12NUX
KEMETIn Stock: 64865EE2-12NUX Datasheet
EE2-12NUX
Current Part
EE2-12NU
KEMETIn Stock: 11677EE2-12NU Datasheet
EE2-12NU
Parametric Equivalent

Key Parameters

Parameter Value
Coil Voltage 12VDC
Contact Form DPDT (2 Form C)
Contact Rating (Current) 2 A
Switching Voltage 250VAC, 220VDC - Max
Mounting Type Surface Mount
Termination Style Gull Wing
Coil Type Non Latching
Operating Temperature Range -40°C ~ 85°C
Contact Material Silver Alloy, Gold Alloy
Coil Resistance 1.03 kOhms
RoHS Status ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution of the EE2-12NUX is determined by strict equivalence across the following critical parameters:

  • Coil Voltage: 12VDC operation
  • Contact Configuration: DPDT (2 Form C) switching arrangement
  • Current Rating: 2A contact capacity
  • Switching Voltage Capability: 250VAC, 220VDC maximum
  • Mounting Technology: Surface mount with gull wing termination
  • Coil Characteristics: Non-latching operation with 1.03 kOhms resistance
  • Environmental Compliance: RoHS3 compliance and REACH unaffected status
  • Temperature Performance: -40°C to 85°C operating range

The EE2-12NU qualifies as a parametric equivalent within the EE2 series, maintaining identical electrical specifications and mechanical form factors.

Parameter Comparison

Parameter EE2-12NUX EE2-12NU
Manufacturer KEMET KEMET
Series EE2 EE2
Coil Voltage 12VDC 12VDC
Contact Form DPDT (2 Form C) DPDT (2 Form C)
Contact Rating (Current) 2 A 2 A
Switching Voltage 250VAC, 220VDC - Max 250VAC, 220VDC - Max
Mounting Type Surface Mount Surface Mount
Termination Style Gull Wing Gull Wing
Coil Type Non Latching Non Latching
Coil Current 11.7 mA 11.7 mA
Must Operate Voltage 9 VDC 9 VDC
Must Release Voltage 1.2 VDC 1.2 VDC
Operate Time 2 ms 2 ms
Release Time 1 ms 1 ms
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C
Contact Material Silver Alloy, Gold Alloy Silver Alloy, Gold Alloy
Coil Resistance 1.03 kOhms 1.03 kOhms
Product Status Active Active
RoHS Status ROHS3 Compliant ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8536.41.0020 8536.41.0020

Engineering Selection Recommendations

Both the EE2-12NUX and EE2-12NU maintain Active product status with identical compliance certifications. The EE2-12NU is a direct parametric equivalent suitable for applications where the EE2-12NUX is specified. Selection between these parts is based on inventory availability and packaging requirements, as both components satisfy identical electrical and mechanical specifications.

The EE2-12NUX is available with 64,840 pieces in stock, while the EE2-12NU maintains 11,603 pieces in inventory. Both parts are supplied in tube packaging and carry full RoHS3 compliance with MSL 1 (Unlimited) moisture sensitivity rating, indicating no special storage or handling requirements beyond standard component practices.

Frequently Asked Questions (FAQ)

Q: Can the EE2-12NU be used as a direct replacement for the EE2-12NUX?

A: Yes. The EE2-12NU is a parametric equivalent with identical coil voltage (12VDC), contact configuration (DPDT), current rating (2A), switching voltage capability (250VAC, 220VDC), and all timing and thermal specifications. Both components are surface mount with gull wing termination and maintain equivalent compliance status.

Q: Are there differences in packaging between these parts?

A: Both the EE2-12NUX and EE2-12NU are supplied in tube packaging. No packaging differentiation exists between these equivalent parts.

Q: What determines substitution eligibility for general purpose relays in the EE2 series?

A: Substitution is determined by equivalence across coil voltage, contact form (DPDT configuration), current rating (2A), switching voltage limits (250VAC/220VDC), mounting type (surface mount), termination style (gull wing), and operating temperature range (-40°C to 85°C). All these parameters must match for functional interchangeability.

Q: Do both parts meet the same compliance requirements?

A: Yes. Both the EE2-12NUX and EE2-12NU are ROHS3 compliant, REACH unaffected, and carry EAR99 ECCN classification with identical HTSUS coding (8536.41.0020). MSL rating is 1 (Unlimited) for both parts.

Q: What is the coil resistance specification for these relays?

A: Both parts maintain a coil resistance of 1.03 kOhms with a coil current of 11.7 mA at 12VDC. Must operate voltage is 9VDC and must release voltage is 1.2VDC.

Q: Are the switching times identical between these parts?

A: Yes. Both the EE2-12NUX and EE2-12NU have an operate time of 2 milliseconds and a release time of 1 millisecond.

Request Quote (Ships tomorrow)