Part Overview
The ECS-80-18-4DN is an 8 MHz through-hole crystal oscillator in HC-49/US package with 18pF load capacitance and 80 Ohms equivalent series resistance. This part is classified as "Not For New Designs," indicating it has reached end-of-life status. Finding equivalent or substitute parts is necessary for ongoing production support, maintenance applications, and legacy system repairs where this frequency and package configuration remain required.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Frequency | 8 MHz |
| Frequency Tolerance | ±30ppm |
| Load Capacitance | 18pF |
| ESR (Equivalent Series Resistance) | 80 Ohms |
| Operating Mode | Fundamental |
| Package / Case | HC-49/US |
| Mounting Type | Through Hole |
| Operating Temperature Range | -40°C ~ 85°C |
Substitute Part Grouping Explanation
Substitution eligibility for the ECS-80-18-4DN is determined by strict alignment of the following parameters:
- Frequency: 8 MHz (exact match required)
- Frequency Tolerance: ±30ppm (exact match required)
- Load Capacitance: 18pF (exact match required)
- ESR: 80 Ohms (exact match required)
- Package / Case: HC-49/US (exact match required)
- Mounting Type: Through Hole (exact match required)
- Operating Mode: Fundamental (exact match required)
Two substitute parts meet these criteria. The ECS-80-18-4XDN provides parametric equivalence with identical electrical specifications and an extended operating temperature range. The ECS-80-18-4 provides functional equivalence with identical electrical specifications but operates within a narrower temperature range.
Parameter Comparison
| Parameter | ECS-80-18-4DN (Main) | ECS-80-18-4XDN (Substitute) | ECS-80-18-4 (Substitute) |
|---|---|---|---|
| Frequency | 8 MHz | 8 MHz | 8 MHz |
| Frequency Tolerance | ±30ppm | ±30ppm | ±30ppm |
| Frequency Stability | ±100ppm | ±100ppm | ±50ppm |
| Load Capacitance | 18pF | 18pF | 18pF |
| ESR | 80 Ohms | 80 Ohms | 80 Ohms |
| Operating Mode | Fundamental | Fundamental | Fundamental |
| Package / Case | HC-49/US | HC-49/US | HC-49/US |
| Mounting Type | Through Hole | Through Hole | Through Hole |
| Operating Temperature Range | -40°C ~ 85°C | -40°C ~ 85°C | -10°C ~ 70°C |
| Product Status | Not For New Designs | Active | Not For New Designs |
| RoHS Status | RoHS non-compliant | ROHS3 Compliant | RoHS non-compliant |
Engineering Selection Recommendations
The ECS-80-18-4XDN is the primary substitute for the ECS-80-18-4DN. Both parts share identical electrical specifications and operating temperature range. The ECS-80-18-4XDN holds Active product status and meets ROHS3 compliance, making it suitable for new production and long-term availability. The ECS-80-18-4DN is classified as Not For New Designs, indicating limited future availability.
The ECS-80-18-4 provides functional equivalence with identical frequency, tolerance, load capacitance, and ESR specifications. However, its operating temperature range is restricted to -10°C ~ 70°C compared to the -40°C ~ 85°C range of the main part. Selection of this substitute requires verification that the narrower temperature range meets application requirements. The ECS-80-18-4 also carries Not For New Designs status.
For applications requiring compliance with current environmental standards, the ECS-80-18-4XDN is the recommended choice due to its ROHS3 compliance and Active product status.
Frequently Asked Questions (FAQ)
Q: Can the ECS-80-18-4XDN directly replace the ECS-80-18-4DN in existing designs?
A: Yes. Both parts share identical electrical specifications (8 MHz, ±30ppm tolerance, 18pF load capacitance, 80 Ohms ESR) and operate across the same temperature range (-40°C ~ 85°C). The HC-49/US package and through-hole mounting are identical. Direct substitution is supported at the component level.
Q: What is the difference between the ECS-80-18-4 and ECS-80-18-4XDN?
A: The primary difference is operating temperature range. The ECS-80-18-4 operates from -10°C ~ 70°C, while the ECS-80-18-4XDN operates from -40°C ~ 85°C. All other electrical parameters are identical. Selection depends on whether your application requires the extended low-temperature performance of the ECS-80-18-4XDN.
Q: Why is the ECS-80-18-4DN marked as "Not For New Designs"?
A: This designation indicates the part has reached end-of-life status and is no longer recommended for new product development. Existing inventory remains available for legacy system support and maintenance. For new designs, the ECS-80-18-4XDN is the recommended alternative.
Q: Are there RoHS compliance differences between these parts?
A: Yes. The ECS-80-18-4XDN is ROHS3 compliant, while both the ECS-80-18-4DN and ECS-80-18-4 are RoHS non-compliant. If your application or market requires RoHS compliance, the ECS-80-18-4XDN is the only suitable option among these three parts.
Q: Can I use the ECS-80-18-4 in an application requiring -40°C operation?
A: No. The ECS-80-18-4 is rated only to -10°C minimum. Applications requiring operation at -40°C must use the ECS-80-18-4DN or ECS-80-18-4XDN, both of which support the full -40°C ~ 85°C range.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts