Request Quote
(Ships tomorrow)
ECS-36-20-4DN Crystal Equivalent & Substitute Parts
Part Overview
The ECS-36-20-4DN is a 3.6864 MHz through-hole crystal oscillator in HC-49/US package, designed for fundamental mode operation across industrial temperature ranges. This part carries a "Not For New Designs" status, making identification of active equivalent components essential for ongoing production support and new design initiatives. The substitute part ECS-36-20-4XDN provides functional equivalence with improved product lifecycle status.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Frequency | 3.6864 MHz |
| Frequency Tolerance | ±30ppm |
| Load Capacitance | 20pF |
| ESR (Equivalent Series Resistance) | 200 Ohms |
| Operating Mode | Fundamental |
| Operating Temperature Range | -40°C ~ 85°C |
| Package / Case | HC-49/US |
| Mounting Type | Through Hole |
| Size / Dimension | 0.447" L x 0.183" W (11.35mm x 4.65mm) |
| Height - Seated (Max) | 0.138" (4.60mm) |
Substitute Part Grouping Explanation
Substitution between ECS-36-20-4DN and ECS-36-20-4XDN is valid based on the following criteria:
Electrical Parameters (Identical):
- Frequency: 3.6864 MHz
- Frequency Tolerance: ±30ppm
- Load Capacitance: 20pF
- ESR: 200 Ohms
- Operating Mode: Fundamental
- Frequency Stability: ±100ppm
Mechanical Parameters (Identical):
- Package / Case: HC-49/US
- Mounting Type: Through Hole
- Physical Dimensions: 0.447" L x 0.183" W (11.35mm x 4.65mm)
- Height - Seated (Max): 0.138" (4.60mm)
Environmental Parameters (Identical):
- Operating Temperature Range: -40°C ~ 85°C
- Moisture Sensitivity Level: 1 (Unlimited)
These parameters define the substitution group. Both parts are electrically and mechanically interchangeable within the same circuit design.
Parameter Comparison
| Parameter | ECS-36-20-4DN | ECS-36-20-4XDN | Match |
|---|---|---|---|
| Manufacturer | ECS Inc. | ECS Inc. | ✓ |
| Frequency | 3.6864 MHz | 3.6864 MHz | ✓ |
| Frequency Tolerance | ±30ppm | ±30ppm | ✓ |
| Load Capacitance | 20pF | 20pF | ✓ |
| ESR | 200 Ohms | 200 Ohms | ✓ |
| Operating Mode | Fundamental | Fundamental | ✓ |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 85°C | ✓ |
| Package / Case | HC-49/US | HC-49/US | ✓ |
| Mounting Type | Through Hole | Through Hole | ✓ |
| Size / Dimension | 0.447" L x 0.183" W (11.35mm x 4.65mm) | 0.447" L x 0.183" W (11.35mm x 4.65mm) | ✓ |
| Height - Seated (Max) | 0.138" (4.60mm) | 0.138" (4.60mm) | ✓ |
| Product Status | Not For New Designs | Active | Substitute is Active |
| RoHS Status | RoHS non-compliant | ROHS3 Compliant | Substitute is Compliant |
Engineering Selection Recommendations
For Existing Designs Using ECS-36-20-4DN: The ECS-36-20-4XDN serves as a direct functional replacement. All electrical and mechanical parameters are identical, ensuring pin-for-pin and footprint compatibility without circuit modification.
For New Designs: The ECS-36-20-4XDN is the recommended selection due to its Active product status and ROHS3 compliance. The ECS-36-20-4DN carries a "Not For New Designs" designation and RoHS non-compliance status, making it unsuitable for new product development.
Compliance Considerations: If RoHS3 compliance is a design requirement, ECS-36-20-4XDN is the only option from this substitution group. The ECS-36-20-4DN does not meet this requirement.
Frequently Asked Questions (FAQ)
Q: Can ECS-36-20-4XDN replace ECS-36-20-4DN in existing circuits? A: Yes. Both parts share identical electrical specifications (3.6864 MHz, ±30ppm tolerance, 20pF load capacitance, 200 Ohms ESR), operating temperature range (-40°C ~ 85°C), and HC-49/US package dimensions. No circuit redesign is required.
Q: What is the primary difference between these two parts? A: The ECS-36-20-4XDN is an Active product with ROHS3 compliance, while the ECS-36-20-4DN is marked "Not For New Designs" and is RoHS non-compliant. Functionally and mechanically, they are equivalent.
Q: Are the physical dimensions identical? A: Yes. Both parts measure 0.447" L x 0.183" W (11.35mm x 4.65mm) with a maximum seated height of 0.138" (4.60mm). They use the same HC-49/US through-hole package.
Q: Which part should be selected for new product development? A: ECS-36-20-4XDN is the appropriate choice for new designs. It maintains Active product status and meets ROHS3 compliance requirements.
Q: Are there any load capacitance or frequency tolerance differences? A: No. Both parts operate at 3.6864 MHz with ±30ppm frequency tolerance and 20pF load capacitance. They are electrically identical in these critical parameters.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts